Analytical HPLC :  Analytical HPLC-A7835

Analytical HPLC-A7835

Analytical HPLC-A7835 system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time.

View Catalog
Pump Specifications
Model No HPP-B1
Flow rate range 0.0001 to 10 ml / min
Maximum pressure 42 MPa , 0 to 5 ml / min
Column size 4.6 × 250 mm
Sample size 5 μm
Pressure pulsation ≤ 1.5 % at 10 MPa
Flow rate accuracy ± 0.2 % at 1 ml / min
Flow rate repeatability % ≤ 0.15
Gradient accuracy % ± 2
Gradient repeatability % ≤ 0.2
Dimension 450 × 260 × 190 mm
Power supply 90 V to 240 V
Weight 11.2 kg
Detector Specifications
Model No HPD-B2
Wavelength range 190 to 800 nm
Wavelength accuracy ± 0.75 nm
Wavelength repeatability 0.2 nm
Band width 8 nm
Optical path 10 nm
Deuterium lamp 190 to 400 nm
Tungsten lamp 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.5 × 10 -5
Baseline drift ( Static ) Au / h ≤ 1.5 x 10 -4
Minimum detection limit ≤ 4 x 10 -8
Power 100 W
Power supply 90 V / 50 to 60 Hz
Dimension 460 × 260 × 190 mm
Weight 9.2 kg
  • Compression compensation ensuring gradient repeatability
  • Low pressure gradient
  • Detector ( Deuterium or tungsten lamp )
  • Simultaneous working of deuterium and tungsten lamp
  • Automatic sample injector ( Autosampler )
  • External pump control by panel or computer software
  • Auto save last detected records by the detector
  • 10 point calibration pump for linear pressure control
  • Error alarm function for over pressure ,under pressure and leakage

Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis

Accessory Quantity
Pump 2
UV-Vis detector ( without flow cell ) 1
Analytical flow cell 1
Injection valve 1
20 μl sample loop 1
4.6 x 250 mm ( 5μm ) analytical column 1
Solvent tray 1
Binary gradient kit 1
Mixing chamber 1

Accessory Quantity
Autosampler 1
Fraction collector 1
Column oven 1

Standard HPLC

HPLC system LHLC-A10

Standard HPLC : HPLC system LHLC-A10
High pressure pumpSingle pump
Flow rate range0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range≤ 0.5 MPa (0 - 42 MPa)
Flow rate precisionRSD < 0.06 %
Pulsation≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa)

HPLC system LHLC-A11

Standard HPLC : HPLC system LHLC-A11
High pressure pumpTwo sets of pump
Flow rate range0.001 - 9.999 mL / min (0.001 mL / min increments)
Pressure range≤ 0.5 MPa (0 - 42 MPa)
Flow rate precisionRSD < 0.06 %
Pulsation≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa)
HPLC system LHLC-B11
Standard HPLC : HPLC system LHLC-B11
High pressure pumpHigh pressure constant-current infusion pump
Infusion WayMicro volume series dual-piston
Infusion pressure0 - 9999 Psi
Flow rate≤ 0.5 %
Flow rate range0.001 - 9.999 mL / min (in 0.001 mL / min increments)
HPLC system LHLC-B10
Standard HPLC : HPLC system LHLC-B10
High pressure pumpHigh pressure gradient pump
Peak operating pressure45 MPa, Stainless steel pump
Pressure± 0.02 MPa
Flow rate range0.001 - 9.999 mL / min
Flow rate precision± 5 %

Analytical HPLC

Analytical HPLC-A7832

Analytical HPLC : Analytical HPLC-A7832
Detector Specifications Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
Pump Specifications
Flow rate range0.0001 to 10 ml / min
Maximum pressure50 MPa , 0 to 2 ml / min
Column size4.6 × 250 mm
Sample size5 µm
Pressure pulsation≤ 1 % at 10 MPa
Flow rate accuracy± 0.15 % at 1 ml / min
Flow rate repeatability %≤ 0.1
Gradient accuracy %± 1.5
Gradient repeatability %≤ 0.2
Dimension460 × 310 × 180 mm
Power supply90 V
Weight11.6 kg

Analytical HPLC-A7840

Analytical HPLC : Analytical HPLC-A7840
Pump Specifications
Solvent deliveryDouble plunger series mode, floating plunger design, single stroke volume 30 µl
Pump Head10 ml stainless steel pump head
Flow rate range0.001 to 9.999 ml / min
Flow rate increment0.001 ml/min
Maximum pressure42 MPa
Column size4.6 × 250 mm 5 µm
Pipeline Size1/16 inch
Flow rate accuracy± 0.5 %
Flow rate precisionRSD ≤ 0.1%
Gradient accuracy %± 0.5 %
Gradient repeatability %RSD ≤ 0.15%
GLPAutomatic recording of pump sealing ring working time
DisplayLCD backlight display
Power80 W
Power supply220 V ± 10%, 50 Hz
Dimension398 × 149 × 267 mm
Detector Specifications
Wavelength range190 to 700 nm
Wavelength accuracy± 1 nm
Wavelength repeatability0.2 nm
Deuterium lamp190 to 400 nm
Tungsten lamp400 to 700 nm
Baseline noise ( Static ) Au1 × 10-5 AU/h at 254 nm with methanol/water= 80/20
Baseline drift ( Static ) Au / h1.5 × 10-4 AU/h at 254 nm with methanol/ water= 80/20
Time constants16 grades adjustable
DisplayLCD backlight display
GLPTotal number of lights, lamp replacement time and product serial number
Power75 W
Power supply220 V ± 10%, 50 Hz
Dimension (L × W × H)398 × 149 × 267 mm
Analytical HPLC System LAHS-A10
Analytical HPLC : Analytical HPLC System LAHS-A10
Pump specification
TypeQuaternary Low Pressure Pump
Flow Rate Range0.001 to 10.000 ml/min, in 0.001ml increments
Flow Accuracy≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)
Flow PrecisionRSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa)
Maximum Pressure63 MPa
Pressure accuracy≤ ± 3.0 %
Pressure pulsation≤ 0.1 MPa
Composition rang0 to 100 %
Composition precision≤ 0.3 % RSD
UV/VIS Detector
Wavelength Range190 to 800 nm
Wavelength Repeatability≤ 0.1 nm
Wavelength Accuracy≤ ± 1.0 nm
Band Width6 nm
Response Time0.0 s to 5 s
Baseline Noise≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s)
Drift≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min)
Path length10 mm(analytical cell)
Light SourceDeuterium Lamp and Tungsten Lamp
Data-processing WorkstationSystem contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA
System Kits1 Set Combined A/D converters Combined vacuum degasser and 4 channel
Power SupplyAC 110 /220 V ±1 0 %, 50/60 Hz
Analytical HPLC System LAHS-B10
Analytical HPLC : Analytical HPLC System LAHS-B10
High Pressure Constant Flow Pump
Double plunger reciprocating pump1 set
Flow range0.001 to 10.00 mL/min
Setting step size0.001 mL/min
Flow accuracy≤ ± 0.3 %
Flow stabilityRSD ≤ 00.1 %
Maximum pressure42 MPa
Display pressure error≤ 1.0 %
Pressure fluctuation≤ 1.0 %
Power consumption80 W
UV/Visible Detector
Wavelength range190 to 700 nm
Wavelength repeatability± 0.1 nm
Band width8 nm
Response time0 to 4.9 seconds
Linearity range1.8 AU (5 %)
Baseline Noise≤ ± 1 × 10-5AU
Baseline drift≤ 2.0 × 10-4AU/h
Minimum detectable concentration4.0 × 10-9 g/mL
Detector cellOptical path: 10 mm Volume: 10 µL
Light sourceDeuterium lamp
Power consumption100 W
VoltageAC 110 V/ 220 V ± 10 %, 50/60 Hz
Packing Dimensions (W × D × H)600 × 440 × 380 mm 2 × (600 × 410 × 300 mm
Gross weight54 kg