Atomic Absorption Spectrophotometer :  Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It consist of 1800/mm reticle large are grating monochromator and titanium burner to improve the analysis efficiency and accuracy of the flame. Atomic Absorption spectrophotometer has manual 3 lamp holder configuration & 3 independent lamp power supply for analysis.

View Catalog
Wavelength range 180 – 900 nm
Spectral Bandwidth 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic)
Absorbance Range 0 - 4 A
Lamp holder ≤ 3 lamps automatic turret, automatic alignment
Lamp power supply mode pulsed power supply
Optical System large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit (Cu) 0.002 μg/mL
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5 %
Ignition Type Microcomputer control, automatic ignition
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
  • 1800 /mm reticle (dispersion rate) large area grating monochromator
  • High performance hollow cathode lamp
  • Titanium burner for the flame analysis
  • Polymer automization chamber
  • Automatic analysis for sensitivity and reproducibility
  • High precision automatic optical system
  • Flame, graphite furnace operating mode can be switched automatically
  • Light source 3 lamp holder
  • Convenient data processing & sharing & printing
  • Powerful software with automatic instrument and additional control

Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B30

Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B30
Wavelength range190 to 1100 nm
Spectral bandwidth2 nm
Wavelength Accuracy± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm
Optical systemDouble beam 1200 lines/mm

Double Beam UV/Vis Spectrophotometer LUS-B31

Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B31
Wavelength range190 to 1100 nm
Spectral bandwidth1 nm
Wavelength Accuracy± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm
Optical systemDouble beam 1200 lines/mm
Double Beam UV/Vis Spectrophotometer LUS-B32
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B32
Wavelength range190 to 1100 nm
Spectral bandwidth0.5/1/2/4/5 nm
Wavelength Accuracy± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm
Optical systemDouble beam 1200 lines/mm
Double Beam UV/Vis Spectrophotometer LUS-B16
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B16
Wavelength Range190 ~ 1100 nm
Setting WavelengthAutomatic
Spectral Bandwidth0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Wavelength Accuracy± 0.3 nm
Wavelength Repeatability≤ 0.1 nm

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A10

Nano Spectrophotometer : Nano Spectrophotometer LNS-A10
Wavelength range200 - 800 nm
Path length0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy± 1 nm
Wavelength Resolution≤ 3 nm (FWHM at Hg 546 nm)
Minimum Sample size0.5 - 2.0 µl

Nano Spectrophotometer LNS-A21

Nano Spectrophotometer : Nano Spectrophotometer LNS-A21
Wavelength range200 - 850 nm
Path length1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy± 1 nm
Wavelength Resolution2 nm (FWHM at Hg 546 nm)
Minimum Sample size0.3 - 2.0 µl
Nano Spectrophotometer LNS-B11
Nano Spectrophotometer : Nano Spectrophotometer LNS-B11
Wavelength range230 nm, 260 nm, 280 nm
Path length1.0 mm, 0.2 mm
Minimum Sample size0.3 - 2.0 µl
Absorbance range0.2 - 75A (10 mm equivalent absorbance)
Absorbance precision0.002 Abs
Nano Spectrophotometer LNS-C10
Nano Spectrophotometer : Nano Spectrophotometer LNS-C10
CuvetteNo
PCInbuilt
Wavelength range190 - 850 nm
Path length1 mm, 0.2 mm ,0.04 mm
Wavelength accuracy± 1 nm

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Vis Spectrophotometer LUS-A50

Single Beam UV/Visible Spectrophotometer : Single Beam UV/Vis Spectrophotometer LUS-A50
Wavelength range190 to 1100 nm
Spectral bandwidth2 nm
Wavelength Accuracy± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm
Optical systemSingle beam 1200 lines/mm

Single Beam UV/Vis Spectrophotometer LUS-A51

Single Beam UV/Visible Spectrophotometer : Single Beam UV/Vis Spectrophotometer LUS-A51
Wavelength range190 to 1100 nm
Spectral bandwidth1 nm
Wavelength Accuracy± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm
Optical systemSingle beam 1200 lines/mm
Single Beam UV/Vis Spectrophotometer LUS-A52
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Vis Spectrophotometer LUS-A52
Wavelength range190 to 1100 nm
Spectral bandwidth0.5/1/2/4/5 nm
Wavelength Accuracy± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm
Optical systemSingle beam 1200 lines/mm
Single Beam UV/Visible Spectrophotometer LUS-A10
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A10
Wavelength Range190 ~ 1100 nm
Spectral Bandwidth1 nm
Wavelength Accuracy± 0.3 nm
Wavelength Repeatability0.2 nm
Photometric Range0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Vis Spectrophotometer LVS-A10

Visible Spectrophotometer : Vis Spectrophotometer LVS-A10
Wavelength Range330 to 1000 nm
Spectral Bandwidth5 nm
Wavelength Accuracy± 2 nm
Wavelength Repeatability≤ 1.0 nm
Photometric RangeT: 0 to199.9%, A: -0.3 to2.5 Abs, F; 0 to 9999, C: 0 to 9999

Vis Spectrophotometer LVS-A11

Visible Spectrophotometer : Vis Spectrophotometer LVS-A11
Wavelength Range335 ~ 1000 nm
Spectral Bandwidth4 nm
Wavelength Accuracy± 2 nm
Wavelength Repeatability1 nm
Photometric RangeT: 0 ~ 199.9 % , A: (-0.3) ~ 2.5A bs, F: 0 ~ 9999, C: 0 ~ 9999
Vis Spectrophotometer LVS-B10
Visible Spectrophotometer : Vis Spectrophotometer LVS-B10
Wavelength Range325 ~ 1000 nm
Setting WavelengthAutomatic
Spectral Bandwidth2 nm
Wavelength Accuracy± 1.0 nm
Wavelength Repeatability≤ 0.2 nm
Vis Spectrophotometer LVS-C10
Visible Spectrophotometer : Vis Spectrophotometer LVS-C10
Wavelength Range320 ~ 1100 nm
Spectral Bandwidth4 nm
Wavelength Accuracy± 0.5 nm
Wavelength Repeatability≤ 0.2 nm
Photometric Range(-0.3) ~ 3 A

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A13

Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A13
Working spectral range190 to 900 nm
Spectral Bandwith0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy± 0.15 nm
Wavelength repeatability≤ 0.04 nm
Baseline stability≤ 0.002 Abs / 30 min

Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A11
Wavelength range190 - 900 nm
Spectral Bandwidth0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy≤ ± 0.5 nm
Wavelength repeatability≤ 0.3 nm(single direction)
Baseline drift± 0.004 Abs / 30 min
Atomic Absorption Spectrophotometer LAAS-A20
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A20
Wavelength range180 - 900 nm
Spectral Bandwidth0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy≤ 0.15 nm
Wavelength repeatability± 0.1 nm
Baseline drift≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic)
Atomic Absorption Spectrophotometer LAAS-A22
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A22
Wavelength range180 – 900 nm
Spectral Bandwidth0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
Wavelength accuracy≤ 0.15 nm
Wavelength repeatability± 0.1 nm
Baseline drift≤ ± 0.002 Abs/30 min (Static) ≤ ± 0.005 Abs/30 min (Dynamic)

Table Top Spectrophotometer

Table Top Spectrophotometer LTS-A15

Table Top Spectrophotometer : Table Top Spectrophotometer LTS-A15
Wavelength Range400 nm to 700 nm
Wavelength Interval10 nm
SensorHigh sensitivity silicon photodiode
Light SourceLED
Working Temperature Range0 ℃ to 45 ℃

Table Top Spectrophotometer LTS-A16

Table Top Spectrophotometer : Table Top Spectrophotometer LTS-A16
Wavelength Range360 nm to 780 nm
Wavelength Pitch10 nm
SensorSilicon Photodiode Array
Grating MethodConcave Grating
Sphere Diameter152 mm
Table top spectrophotometer LTS-A10
Table Top Spectrophotometer : Table top spectrophotometer LTS-A10
Illumination systemd/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere40 mm, alvan diffused reflection surface coating
Illumination light sourceCLED
SensorDual light path sensor array
Light sourceA, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Table top spectrophotometer LTS-A11
Table Top Spectrophotometer : Table top spectrophotometer LTS-A11
Illumination systemd/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere40 mm, alvan diffused reflection surface coating
Illumination light sourceCLED
SensorDual light path sensor array
Light sourceA, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF

Portable Spectrophotometer

Portable Spectrophotometer LSP-A30

Portable Spectrophotometer : Portable Spectrophotometer LSP-A30
Illumination45/0 (45 ring shaped illumination,0° observation angle)
RepeatabilityLight splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab
SensorHigh sensitivity silicon photodiode
Test angle-
Test area-

Portable Spectrophotometer LSP-A31

Portable Spectrophotometer : Portable Spectrophotometer LSP-A31
Illumination45/0 (45 ring shaped illumination,0° observation angle)
RepeatabilityLight splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab
SensorHigh sensitivity silicon photodiode
Test angle60°
Test area5 × 10 mm
Portable spectrophotometer LSP-A10
Portable Spectrophotometer : Portable spectrophotometer LSP-A10
Illuminationd/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
RepeatabilityLight splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
SensorBlue light enhanced sensor array
Size of integrated sphere40 mm, alvan diffused reflection surface coating
Illumination light sourceCLED
Portable spectrophotometer LSP-A11
Portable Spectrophotometer : Portable spectrophotometer LSP-A11
Illuminationd/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
RepeatabilityLight splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab Maximum:0.03
SensorDual light path sensor array
Size of integrated sphere40 mm, alvan diffused reflection surface coating
Illumination light sourceCLED

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer LFS-A10

Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A10
Light source150 W Xenon lamp
Excitation wavelength200 nm to 900 nm
Emission wavelength200 nm to 900 nm
Excitation slit2 nm, 5 nm, 10 nm, 20 nm
Emission slit2 nm, 5 nm, 10 nm, 20 nm

Fluorescence Spectrophotometer LFS-A12

Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A12
Light source150 W Xenon lamp
Excitation wavelength200 nm to 900 nm
Emission wavelength200 nm to 900 nm
Excitation slit2 nm, 5 nm, 10 nm, 20 nm
Emission slit2 nm, 5 nm, 10 nm, 20 nm
Fluorescence Spectrophotometer LFS-A11
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A11
Excitation Source150 W Xenon Lamp
Excitation Wavelength200 nm to 900 nm
Excitation Slit1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Emission Slit1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Wavelength Accuracy± 0.4 nm

Xenon Lamp Spectrophotometer

Xenon Lamp Spectrophotometer LXLS-A10

Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A10
Optical systemDouble Beam, Grating 1200 lines/mm
Wavelength Range190 nm to 1100 nm
Spectral Bandwidth2 nm
Wavelength Accuracy± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm

Xenon Lamp Spectrophotometer LXLS-A11

Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A11
Optical systemDouble Beam, Grating 1200 lines/mm
Wavelength Range190 nm to 1100 nm
Spectral Bandwidth1 nm
Wavelength Accuracy± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm
Xenon Lamp Spectrophotometer LXLS-A13
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A13
Optical systemDouble Beam, Grating 1200 lines/mm
Wavelength Range190 nm to 1100 nm
Spectral Bandwidth2 nm
Wavelength Accuracy± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm
Xenon Lamp Spectrophotometer LXLS-A14
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A14
Optical systemDouble Beam, Grating 1200 lines/mm
Wavelength Range190 nm to 1100 nm
Spectral Bandwidth1 nm
Wavelength Accuracy± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability≤ 0.1 nm