Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10 is designed and made as per “Test Methods for Demulsibility Characteristics of Petroleum Oils and Synthetic Fluids” ASTM D1401.
View CatalogAmbient temperature | Room temperature to 35 °C |
---|---|
Relative humidity | ≤ 85 % |
Timing range | 1 s to 9 min 59 s |
Temperature controlling range | Room temperature to 99.9 °C |
Temperature controlling accuracy | ± 1 °C |
Temperature resolution | 0.1 °C |
Stirring speed | 1500 ± 15 rpm |
Heating power for temperature controlling | 600 W |
Total power consumption | ≤ 800 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Dimension | 520 × 460 × 122 mm |
It can be widely used in the field of petroleum , chemical industry and scientific research
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Operation Mode | The outer barrel temperature is constant |
Temperature resolution | 0.0001°C |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Operation Mode | A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode |
Temperature resolution | 0.0001°C |
Calorimeter type | Isoperibol |
Oxygen filling | Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering |
Bomb volume | 250 ml |
Analysis time | < 8 min full test process: |
Bomb washing | Manual |
Calorimeter type | Isoperibol |
Oxygen filling | Semi-automatic |
Bomb volume | 282 ml |
Analysis time | 15 to 25 min |
Bomb washing | Manual |
Measuring Range For Aviation Gasoline | 86.0 to 105.0/MON |
Measuring Range For Gasoline For Motor Vehicles | National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON |
Measuring Range For Ethanol | E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON |
Measuring Range For Automobile Diesel Fuels | Cetane number: 25 to 75/CN Cetane index: 20 to 80/CI |
Measuring Accuracy | Aviation gasoline: ≤ ± 1.5/MON Gasoline for motor vehicles: ≤ ± 1.5/RON, ≤ ± 1.5/MO Automobile diesel fuels: ≤ ± 2.6/CN, ≤ ± 2.6/CI Regression sample retest: ≤ ± 0.5/RON, ≤ ± 0.5/MON Regression sample measurement: ≤ ± 1.5/RON, ≤ ± 1.5/MON Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON |
Measurement item | motor gasoline and diesel |
measurement unit of octane is ON | 40 to 120 |
Permissible error of octane | ± 0.5 max |
Fluctuate range of octane | ± 0.2 max |
measurement unit of cetane is CN | 20 to 100 |
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Ambient temperature | (-10 )°C to 35 °C |
Relative humidity | ≤ 85 % |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Precision of titration tube | Scale division is 0.02 ml |
Total power consumption | ≤ 1200 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Measurement range | ≥0.05 mg KOH/g |
Potential measurement range | 0 to 1800.0 mV |
Burette volume | 10 mL |
Minimum titration volume | 0.001 ml |
Burette precision | ±0.1 %FS |
Volumetric analysis | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml |
Automatic acid titration | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH |
Automatic potential control | Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV |
Ambient temperature | 0 ~ 35 ℃ |
Relative humidity | ≤ 85 % |
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Interior Dimension | 360 × 250 × 545 mm |
Exterior Dimension | 370 × 320 × 630 mm |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Power of motor | 2 kW |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Temperature range | 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C |
Aperture of ignition device | 0.8 mm |
Standard oil cup-Inner diameter | 50.7 ~ 50.8 mm |
Ambient temperature | 10 °C ~ 40 °C |
Relative humidity | ≤ 80 % |
Measurement Range | Ambient Temperature ~ 250 °C |
Flash Point | Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C |
Resolution | 0.1 °C |
Ambient temperature | 10 °C ~ 40 ℃ |
Relative humidity | ≤ 80 % |
Ignition Mode | electron igniter / gas flame |
Temperature range | Room Temperature ~ 300 ℃ |
Measurement Range | Room Temperature ~ 300 ℃ |
Ambient temperature | Room temperature to 35 °C |
Relative humidity | ≤ 85 % |
Temperature controlling range | Room temperature to 99.9 °C |
Temperature controlling accuracy | ± 1 °C |
Stirring speed | 1500 ± 15 rpm |
Heating power | 2 kW |
Cooling power | 0.5 kW |
Steam temperature | 0 to 400℃ |
Oven temperature | 0 to 500℃ |
Refrigeration temperature | 0 to 60℃ |
Ambient temperature | -10°C to 35°C |
Relative humidity | ≤ 85 % |
Thermometer | Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C |
Scale division | 0.1 ℃ |
Total length | 8000 mm |
Graduated flasks | 100 ml |
Scale division of graduated flask | 1ml |
Distillation flask | 125 ml |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Graduated flasks | 100 ml |
Distillation flask | 125 ml |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Temperature controlling accuracy | ± 0.5 °C |
Beaker quantity | 600 ml |
Ambient temperature | (-10) °C ~ 40 °C |
Relative humidity | ≤ 85 % |
Thermometer Measurement range | (-5) °C ~ 300 °C |
Thermometer Scale division | 1 °C |
Ambient temperature | ≤ 35 ℃ |
Relative humidity | ≤ 85 % |
Heating power of electric furnace | 250 W × 2 |
Total power consumption | ≤ 700 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Graduated Flask | 200 ± 0.2 ml |
Standard Water Value | 51 ± 1 s |
Temperature Range | 0 ~ 100 °C |
Temperature Controlling Accuracy | ± 0.2 °C |
Accuracy Of Timer | 0.01 s |
Graduated Flask | 100 ml |
Standard Water Value | 51 ± 1 s |
Temperature Range | 0 ~ 100 °C |
Temperature Controlling Accuracy | ± 0.1 °C |
Accuracy Of Timer | 0.01 s |
Graduated Flask | 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials) |
Standard Water Value | 51 ± 1 s |
Temperature Range | 0 ~ 100 °C |
Ambient Temperature | 10 °C ~ 40 °C |
Temperature Controlling Accuracy | ± 0.1 °C |
Evaporation bath type and size | Aluminum block bath, φ260 × 130 mm |
Holes for testing | 3 pieces |
Size of holes for testing cylinder | φ51 × 70 mm |
Flow rate display | Flow meter |
Working temperature | 60 ℃ to 165 ℃ |
Evaporation bath type and size | Aluminum bath φ260 × 130 mm |
Holes for testing | 5 pieces |
Size of holes for testing cylinder | φ51 × 70 mm |
Working temperature | 160 ℃ ~ 165℃ |
Working pressure for decompression valve | 0.07 MPa |
Bath type | Oil bath |
Bath capacity | 5000 ml ± 50 ml |
Ambient temperature | Room temperature to 35 °C |
Relative humidity | ≤ 85 % |
Temperature controlling range | RT to 250 °C |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 11 pieces |
Stirring motor | 6 W, 1200 rpm |
Temperature controlling accuracy | ± 0.1 °C |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 11 pieces |
Stirring motor | 6 W, 1200 rpm |
Temperature controlling range | Ambient temperature ~ 100 °C |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group |
Stirring motor | 6 W, 1200 rpm |
Sample quantity | 3 piece at the same time |
Ambient temperature | ≤ 30 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 13 pieces |
Stirring motor | 6 W, 1200 rpm |
Temperature controlling range | Ambient temperature ~ 70 °C |
Ambient temperature | (-10)℃ ~ 35 ℃ |
Relative humidity | ≤ 85 % |
Sample cup Inner diameter | 31.0 ~ 32.0 mm |
Sample cup Wall thickness | 1.0 ~ 1.5 mm |
Sample cup Height | 115 ~ 125 mm |
Temperature controlling accuracy | ± 0.5 ℃ |
Refrigeration system | New-type refrigeration compressor |
Cold trough | Two holes in one trough, and same temperature |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Refrigeration system | New-type refrigeration compressor |
Controlling temperature of cold trough | Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Inner Dimensions | 560 x 380 x 250 mm |
Refrigeration system | New-type refrigeration compressor |
Controlling temperature of cold trough | Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Dimensions | 930 x 570 x 108 mm |
Thermometer | 0 ℃ ~ 360 °C |
Scale Division | 1 °C |
Ambient Temperature | ≤ 35 °C |
Relative Humidity | ≤ 85 % |
Outer Crucible-Material | Carbon structural steel |
Thermometer | 6 ℃ ~ 400 ℃ |
Scale Division | 2 °C |
Spout Aperture | 0.6 ~ 0.8 mm |
Ambient Temperature | -10 ℃ ~ 50 ℃ |
Relative Humidity | ≤ 85 % |
Ambient Temperature | 10 ℃ ~ 40 ℃ |
Relative Humidity | ≤ 85 % |
Temperature Measurement- Full Scale | Ambient temperature to ~ 400 ℃ |
Temperature Measurement- Repeatability | ≤ 4 ℃ |
Test accuracy | 0.005 |
Ambient Temperature | 10 ℃ ~ 40 °C |
Relative Humidity | ≤ 80 % |
Temperature Measurement- Full Scale | Ambient temperature to 300 °C |
Temperature Measurement- Repeatability | ≤ 8 °C |
Temperature Measurement- Reproducibility | ≤ 16 °C |
Dimension | 390 x 260 x 590 mm |
Total power consumption | ≤ 1200 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Heating power of water bath | 1000 W |
Relative humidity | ≤ 85 % |
Power supply | AC 220 V ± 10 %, 50 Hz |
Temperature controlling range in water bath | RT ~ 90 ℃ ± 5 ℃ |
Cooling bath temperature | (-35) ℃ ± 1 ℃ |
Evaporation temperature | 35 ℃ ± 1 ℃ |
Flow rate | 2 ~ 3 L / min |
Power supply | AC 220 V ± 5 % , 50Hz |
Measurement range | 0 ~ 75 kV |
Voltage rising rate | 3 kV ± 10 % / s |
Distance between electrodes | 2.5 mm |
Output power | 2 kVA |
Light source | 220 V, 100 W |
Temperature of grinding milk white light bulb | 2750 ± 50 K |
Light hole( Φ14) | 26 pieces |
Color comparing tube | Φ32 mm |
Dimension | 440 x 420 x 340 mm |
Samples | 2 |
Oil bath cubage | 30 L |
Angle between bomb and water surface | 30 ° |
Speed of rotary assembly | 100 ± 5 RPM |
Pressure sensor | 0 to 1.6 Mpa; Accuracy: ±2% |
Samples | 6 |
Temperature controlling mode | Automatic digital temperature |
Temperature controlling range | Room temperature ~ 160 °C |
Temperature controlling accuracy | ± 0.2 °C |
Power supply | 220 V, 50 Hz |
Samples | 8 |
Temperature | 100 ℃ |
Temperature controlling accuracy | 0.1 ℃ |
Flow meter | 3 ± 0.3 L / H oxygen |
Power supply | 220 V ± 10 %, 60 Hz |
Temperature Range | Ambient to 150℃ |
Temperature Precision | ± 0.1°C |
Test Unit | 2 units |
Heating Power | 1800 W |
Ambient Temperature | (Room temperature to 35°C |
Temperature controlling range | 10 ℃ ~ 35 ℃ |
Temperature resolution | 0.001 ℃ |
Mean value of heat capacity | 15 kJ / K |
Ambient temperature | 20 ℃ ± 5 ℃ |
Relative humidity | ≤ 85 % |
Temperature measurement range | 10 ~ 35 ℃ |
Repeatability error | ≤ 0.2 % (Grade C) |
Endured pressure in oxygen bomb | 20 MPa |
Operation environment temperature | 15 ~ 28 ℃ |
Temperature resolution | 0.001 ℃ |
Heat capacity | 14000 ~ 15000 J / K |
Temperature measurement range | 10 ~ 35 ℃ |
Repeatability error | ≤ 0.2 % (Grade C) |
Endured pressure in oxygen bomb | 20 MPa |
Operation environment temperature | 15 ~ 28 ℃ |
Porcelain crucible | 30 ml |
Inner iron crucible | 75 ml |
Outer iron crucible | 190 ml |
Burner | Mig Burner |
Dimensions | 400 x 380 x 270 mm |
Bath type | Four holes with a furnace |
Heating type | Electric resistance furnace |
Temperature controlling range | 0 ~ 520 °C |
Temperature controlling accuracy | ± 5 °C |
Relative humidity | ≤ 85 % |
Coking furnace | Metal furnace |
Heating mode | Electric heating |
Test unit | 5 units |
Temperature range | Ambient to 550°C |
Temperature precision | ≤ ± 5℃ |
Sample hole | 4 pieces |
Sample quantity | 4 to 12 pieces |
Ambient temperature | Room temperature to 35 °C |
Temperature controlling range | Room temperature to 100°C |
Temperature controlling accuracy | ± 1°C |
Sample hole | 2 pieces |
Speed of stirring motor | 1400 rpm |
Ambient temperature | 10 to 35°C |
Temperature controlling range | Room Temperature to 100°C |
Temperature controlling accuracy | ± 0.5°C |
Sample hole | 4 pieces |
Speed of stirring motor | 1400 rpm |
Speed for sample stirring | 1000 ± 50 rpm |
Ambient temperature | Room temperature to 35°C |
Temperature controlling range | 0 to 100°C |
Sample hole | 4 pieces |
Ambient temperature | Room temperature to 35°C |
Temperature controlling range | 0 to 100°C |
Temperature controlling accuracy | ± 1°C |
Relative humidity | ≤ 85 % |
Sample quantity | 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm) |
Measurement time | 60, 120, 240, 300, and 600 s at random |
Measurement range | 7 ppm to 5 % |
Repeatability | < 0.029 (S + 0.6) |
Reproducibility | < 0.063 (S + 0.6) |
Air flow rate | Not less than 150 L / h |
Max. Preset time | 99 min 59 s (100 min) |
Chamber diameter of oven | Φ22 mm |
Heating power of oven | 1400 W × 2 |
Max. Temperature of oven | 950 °C |
Operation temperature of water bath | RT ~ 90 °C |
Temperature controlling accuracy | ± 0.1 °C |
Dimensions | 550 × 520 × 102 mm |
Pressure meter accuracy | ± 0.4 % kPa |
Heating power of water bath | 1600 W |
Test bomb | Two samples or a group of parallel samples |
Bath temperature | 37.8 °C |
Temperature controlling accuracy | 0.1 °C |
Dimensions | 500 × 560 × 680 mm, 950 × 540 × 720 mm |
Heating power of water bath | 1400 W |
Ambient Temperature | 10°C to 35°C |
Measurement Range | 0 to 100 mg |
Resolution | 0.1 µg |
Max. Electrolysis Speed | 40 µg /s |
Amount and Precision of electrolysed water | 10 µg to 1000 µg, ± 2 µg and >1000 µg, 0.2 % |
Ambient Temperature Range | ≤ 35°C |
Relative Humidity | ≤ 85% |
Heating Mantle Cap Power | 1000 W |
Sample Determination | 1 at a time |
Dimension | 580 × 350 × 300 mm |
Ambient Temperature Range | ≤ 35°C |
Relative Humidity | ≤ 85% |
Heating Mantle Cap Power | 1000 W × 2 |
Sample Determination | 2 at a time |
Dimension | 690 × 570 × 310 mm |
Ambient Temperature Range | -10 to 35°C |
Relative Humidity | ≤85% |
Distillation Flask | 1000 ml |
Receiver | 5 ml, with 0.05 ml graduation |
Condenser | 400 mm with ± 5 mm accuracy |
Measurement range | 0 to 600 penetration scale |
Timing controller | 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec |
Time accuracy | ± 0.1 seconds |
Resolution | 0.01 mm |
Penetration accuracy | ± 1 penetration |
Measurement range | 0 to 600 penetration scale |
Timing controller | 5 sec or 60 sec |
Time accuracy | ± 0.1 seconds |
Resolution | 0.01 mm |
Penetration accuracy | ± 1 penetration |
Penetrometer |
|
Circulatory Water Bath |
|
Measurement range | 0 to 600 penetration scale |
Timing range | 0 sec to 60 sec |
Time accuracy error | ≥ ± 0.1 seconds |
Resolution | 0.1 penetration |
Power consumption | 200 W |