Heating incubators LHI-A11 comes with polished stainless-steel chamber. Designed with inner glass door, helps in observing changes occurring in the specimen kept inside during incubation. Heating incubators are equipped with microprocessor-based PID controller for timing functions and controlling temperature parameter. It delivers a higher level of performance for storage of mould and biological cultivations.
View CatalogChamber Volume | 35 L |
---|---|
Shelves | 2 (pcs) |
Display Resolution | 0.1 ℃ / ± 0.5 ℃ |
Temperature Range | RT 5 ℃ ~ 65 ℃ |
Ambient Temperature | 5 ℃ ~ 35 ℃ |
Timing Range | 1 ~ 5999 min |
Interior Dimension (W × D × H) | 340 × 320 × 320 mm |
Exterior Dimension (W × D × H) | 620 × 490 × 490 mm |
Power consumption | 200 W |
Power | 220 V, 50 Hz |
Heating incubators have useful scientific & research applications in agricultural, biological and other research departments.
Intelligent programmable temperature controller
Printer
Independent temperature-limiting Alarm system
RS485 connector
It incorporates advantage of both closed and shaking incubation required for no. of processes which includes tissue culture, enzyme reaction, fermentation etc. It is highly efficient with user-friendly operation.
Display | LCD |
Circulation Mode | Forced convection |
Shaking Mode | Rotatory Shaking |
Drive Mode | Unishaft drive |
Temperature Range | 4 °C to 60 °C |
Display | LCD |
Circulation Mode | Forced convection |
Shaking Mode | Rotatory Shaking |
Drive Mode | Unishaft drive |
Temperature Range | RT + 5 °C to 60 °C |
Shaking Speed Range | 40 to 300 rpm |
Platform Size | 280 × 220 mm |
Display Resolution | 0.1 ℃ |
Temperature Range | Room temperature +5 ℃ to 50 ℃ |
Timing Range | 1 to 5999 minutes |
Shaking Speed Range | 40 to 300 rpm |
Platform Size | 350 × 350 mm |
Display Resolution | 0.1 ℃ |
Temperature Range | Room temperature +5 ℃ to 50 ℃ |
Timing Range | 1 to 5999 minutes |
This wide range of cooling incubators is available in different temperature ranges and it is suitable to serve for preservation of culture medium, serum, medicine as well as micro-organism training and environmental testing, etc.
Shelves | 3(pcs) |
Display Resolution | 0.1 ℃ |
Temperature Range | (-10) ℃ ~ 65 ℃ |
Temperature Stability | High: ± 0.5 ℃ Low: ± 1 ℃ |
Ambient Temperature | 5 ℃ ~ 35 ℃ |
Shelves | 3(pcs) |
Display Resolution | 0.1 ℃ |
Temperature Range | (-20) ℃ ~ 65 ℃ |
Temperature Stability | High: ± 0.5 ℃ Low: ± 1 ℃ |
Ambient Temperature | 5 ℃ ~ 35 ℃ |
Shelves | 3(pcs) |
Display Resolution | 0.1 ℃ |
Temperature Range | (-40) ℃ ~ 65 ℃ |
Temperature Stability | High: ± 0.5 ℃ Low: ± 1 ℃ |
Ambient Temperature | 5 ℃ ~ 35 ℃ |
Shelves | 3(pcs) |
Display Resolution | 0.1 ℃ |
Temperature Range | (-10) ℃ ~ 65 ℃ |
Temperature Stability | High: ± 0.5 ℃ Low: ± 1 ℃ |
Ambient Temperature | 5 ℃ ~ 35 ℃ |
Equipped with inner glass door for easy operation, our heating incubators deliver a higher level of performance for storage and cultivation purpose. This range is available in different chamber volume.
Chamber Volume | 16 L |
Shelves | 2 (pcs) |
Display Resolution | 0.1 ℃ / ± 0.5 ℃ |
Temperature Range | RT 5 ℃ ~ 65 ℃ |
Ambient Temperature | 5 ℃ ~ 35 ℃ |
Chamber Volume | 50 L |
Shelves | 2 (pcs) |
Display Resolution | 0.1 ℃ / ± 0.5 ℃ |
Temperature Range | RT 5 ℃ ~ 65 ℃ |
Ambient Temperature | 5 ℃ ~ 35 ℃ |
Chamber Volume | 80 L |
Shelves | 2 (pcs) |
Display Resolution | 0.1 ℃ / ± 0.5 ℃ |
Temperature Range | RT 5 ℃ ~ 65 ℃ |
Ambient Temperature | 5 ℃ ~ 35 ℃ |
Chamber Volume | 160 L |
Shelves | 2 (pcs) |
Display Resolution | 0.1 ℃ / ± 0.5 ℃ |
Temperature Range | RT 5 ℃ ~ 65 ℃ |
Ambient Temperature | 5 ℃ ~ 35 ℃ |
Temperature range | RT. 5°C ~ 160°C |
Temperature accuracy | ± 0.5 °C at 40 °C ; ± 1 °C at 120°C |
Temperature uniformity | ± 0.5 °C |
Block quantity | 1 or 2 |
Heating time | ≤ 15 min (25 °C ~ 160 °C) |
Temperature range | RT. 5°C ~ 130°C |
Temperature accuracy | ± 0.5 °C at 40 °C ; ± 1 °C at 120°C |
Temperature uniformity | ± 0.5 °C |
Block quantity | 4 |
Heating time | ≤ 20 min (25 °C ~ 130 °C) |
Temperature range | RT. 5°C ~ 100°C |
Temperature accuracy | ≤ ± 0.3°C |
Temperature uniformity | ≤ ± 0.3 °C |
Temperature stability | ± 0.3°C |
Heating time | ≤ 10 min (25°C ~ 100°C) |
Temperature range | RT. 5°C ~ 100°C |
Temperature setting range | 0 °C - 100 °C |
Temperature accuracy | ≤ ± 0.3 °C |
Temperature uniformity | ≤ ± 0.3 °C |
Heating time | ≤ 12 min (25°C ~ 100°C) |
Chamber Volume | 50 L |
Shelves | 2(pcs) |
Display Resolution | 0.1 ℃ |
Heating Method | Water Temperature |
Temperature Range | RT 5 ℃ ~ 65 ℃ |
Chamber Volume | 80 L |
Shelves | 2(pcs) |
Display Resolution | 0.1 ℃ |
Heating Method | Water Temperature |
Temperature Range | RT 5 ℃ ~ 65 ℃ |
Chamber Volume | 160 L |
Shelves | 2(pcs) |
Display Resolution | 0.1 ℃ |
Heating Method | Water Temperature |
Temperature Range | RT 5 ℃ ~ 65 ℃ |
Chamber Volume | 270 L |
Shelves | 2(pcs) |
Display Resolution | 0.1 ℃ |
Heating Method | Water Temperature |
Temperature Range | RT 5 ℃ ~ 65 ℃ |
Capacity | 250 L |
Illumination type | 2 side illumination |
Light source | Fluorescent lamp |
Lighting illumination | 0 to 12000 lx |
Illumination control | 6 degrees adjustable |
Capacity | 350 L |
Illumination type | 2 side illumination |
Light source | Fluorescent lamp |
Lighting illumination | 0 to 15000 lx |
Illumination control | 6 degrees adjustable |
Capacity | 450 L |
Illumination type | 2 side illumination |
Light source | Fluorescent lamp |
Lighting illumination | 0 to 20000 lx |
Illumination control | 6 degrees adjustable |
Capacity | 250 L |
Illumination type | 3-side illumination |
Illumination source | Fluorescent lamp |
Lighting illumination | 0 to 12000 lx |
Lighting Illumination Control | 6 degree relative illumination control |
Capacity | 350 L |
Illumination type | 3-side illumination |
Illumination source | Fluorescent lamp |
Lighting illumination | 0 to 20000 lx |
Lighting Illumination Control | 6 degree relative illumination control |
Capacity | 450 L |
Illumination type | 3-side illumination |
Illumination source | Fluorescent lamp |
Lighting illumination | 0 to 20000 lx |
Lighting Illumination Control | 6 degree relative illumination control |
Control System | Microcomputer control system |
Display | LCD display with button-press keypad |
Time for creating anaerobic state in sample chamber | < 5 minutes |
Time for creating anaerobic state in operation chamber | < 1hr |
Anaerobic environment maintenance time | > 12 hrs (when no supply of mixed gas) |
Control System | Microprocessor control system + Siemens PLC |
Display | LCD display with touch screen control panel |
Time for creating anaerobic state in sample chamber | < 5 minutes |
Time for creating anaerobic state in operation chamber | < 1 hr |
Anaerobic environment maintenance time | > 12 hrs (when no supply of mixed gas) |
Time for creating anaerobic state in sample chamber | < 5 min |
Time for creating anaerobic state in operation chamber | < 1 hour (Oxygen concentration ≤ 1 %) |
Anaerobic environment maintenance time | > 12 h (when no supply of mixed gas) |
Range of temperature control in incubation chamber | RT + 3°C to 60°C |
Temperature stability in incubation chamber | < ± 0.3°C |
Air cycle Mode | Gravity air convection |
Function |
|
Body structure |
|
Controller |
|
Safety Device | Over temperature sound-light alarm |
Air cycle Mode | Natural air convection |
Function |
|
Body structure |
|
Controller |
|
Safety Device | Parameter memory over-temperature audible alarm, automatic power-off function |
Air cycle Mode | Natural air convection |
Function |
|
Body structure |
|
Controller |
|
Safety Device | Parameter memory over-temperature audible alarm, automatic power-off function |
Capacity | 100 L |
Temperature range | 0 to 60°C |
Accuracy | ± 0.5°C |
Ambient temperature | 0 to 60°C |
Temperature fluctuation | ± 0.5°C |
Capacity | 150 L |
Temperature range | 0 to 60°C |
Accuracy | ± 0.5°C |
Ambient temperature | 0 to 60°C |
Temperature fluctuation | ± 0.5°C |
Capacity | 250 L |
Temperature range | 0 to 60°C |
Accuracy | ± 0.5°C |
Ambient temperature | 0 to 60°C |
Temperature fluctuation | ± 0.5°C |
Capacity | 400 L |
Temperature range | 0 to 60°C |
Accuracy | ± 0.5°C |
Ambient temperature | 0 to 60°C |
Temperature fluctuation | ± 0.5°C |