Cabinet Type | Upright |
Capacity | 450 L |
Temperature Range | -10˚ to -25˚C |
Ambient Temperature | 16˚ to 32˚C |
Cooling Performance | -25˚C |
Capacity | 340 L |
Door type | Dual door manual |
Adjustable shelf | 2 |
Shelves loading capacity | 100 kgs |
Dimension ( H x W x D ) | 1650 x 1090 x 860 mm |
Ozone measurement range | 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm |
Flow rate | 1 L/min |
Accuracy | 0.01 ppm |
Measuring time | 10 seconds |
Boot time | ≤ 10 min |
Viewing head | Monocular viewing head |
Eyepiece | 10X/ 18 mm |
Objectives |
4X/N.A. 0.08, working distance= 16 10X/N.A. 0.25, working distance= 3.6 40X/N.A. 0.6, working distance= 0.6 |
Nosepiece | Triple nosepiece 4X/ N.A. 0.8, WD 16 mm |
Optical system | Finite optical system |
Temperature Range | 5 °C - 450 °C |
Digestion Tube Capacity | 280 ml |
Capacity Per Batch | 20 pcs / batch |
Heating Method | Infrared heating and high-purity graphite conduction |
Heating Insulation Method | Ceramic fibre and Unique air duct insulation technology |
Capacity | 2000 kgs / 24 hrs |
Storage Bin Capacity | 480 kgs |
Refrigeration System | R404A |
Cooling Mode | Air/Water Cooling |
Cooling Fan | EBM(Germany) |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Operation Mode | A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode |
Temperature resolution | 0.0001°C |
Capacity | 130 L |
Shelves | 3 |
Temperature | 2 °C to 8 °C |
Temperature accuracy | 0.1 °C |
Refrigerant | R134a / R600a |
Exterior Size (W × D × H) | 1800 × 800 × 2200 mm |
Interior Size (W × D × H) | 1580 × 600 × 1650 mm |
Maximum Opening | 1300 mm |
LED Lamp | 16 W × 2 |
Illumination | ≥ 800 Lux |
Shaking Speed Range | 50 - 250 rpm |
Platform Dimension | 280 x 270 mm |
Shaking Orbit | 10 mm |
Shaking Motion | Orbital |
Display | Analog |
Capacity | 400 L |
Sterilization Temperature | 134 °C |
Sterilization Pressure | 0.22 MPa |
Timer Range | 0 - 60 minutes |
Heat Average | ≤ ± 1 ℃ |
Graduated flasks | 10 ml and 100 ml |
Scale division of graduated flask | 10 ml is 0.1 ml and 100 ml is 1 ml |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Thermometer | 0 °C ~ 360 °C |
Air Velocity |
|
|||||||||||||||
Air Flow |
|
|||||||||||||||
Beaufort Scale |
Range: 0 to 12 Resolution: 0.1 Accuracy: ± 0.5 |
|||||||||||||||
Wave Height |
Range: 0 to 14 Resolution: 0.1 Accuracy: ± 0.1 |
|||||||||||||||
Air Temperature |
|
Temperature Range | RT + 100 °C ~ 850 °C |
Humidity range | At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 % |
Testing Time | 20 hours |
Testing Voltage | 120 V ~ 145 V (135 V) |
Testing Current | 15 A ~ 17 A (16 A) |
Temperature Range | 40 °C to 50°C |
Measurement Ranges |
Counting rate: 0 to 500000 CPM, 0 to 8000 CPS Radiation dose rate: 0.01 to 10000 u Sv/h |
Energy Ranges | 25 KeV to 7 MeV |
Display Unit | CPM, CPS, Bq/cm2 , μ Gy/h ,μ Sv/h |
Detector | Pancake GM tube. Φ : 45 mm |
No of vessels | 6 |
No of poles | 6 |
Position of vessels and poles | Six vessel and six pole arranged on one line |
Head part movement | Manually turn over |
Preset time (for 9 points) | 1 to 999 mins |
Measuring System |
Measuring Range: 0 to 3.0 OD Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear Photometric linearity: ±2% (0 to 3.000 OD) Photometric accuracy: ±1% (0 to 3.000 OD) Carry over: ≤1% |
Photometric System |
Light source: 6 V, 10 W halogen lamp; standby function Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request) Wavelength Accuracy: ±2 nm |
Thermostatic Control |
Temperature: 25˚C, 30˚C, 37˚C Precision: ±0.1˚C |
Drift | <0.005 OD/hr |
Reading Cuvette | Flow through cell cuvette |
Chamber Volume | 220 L |
Sterilization temperature | 50 ± 5°C |
Working pressure | -50 Pa |
Sterilizing agent | 60 % (H2O2) hydrogen peroxide |
Sterilizing time | 45 to 50 min |
Volume Range | 0.5 to 5 ml |
Graduation | 0.1 ml |
Accuracy | ≤ ± 0.5 %, ≤ ± 25 μl |
CV (Coefficient of variation) | ≤ 0.1 %, ≤ 5 µl |
Parameters for Liquid | Vapor pressure Maximum 500 mbar viscosity maximum 500 mm2/s temperature maximum 40°C density maximum 2.2 g/cm3 |
Drug/Narcotic identification | Cocaine hydrochloride, Heroin hydrochloride, Tetrahydrocannabinol, Methamphetamine, Ketamine hydrochloride (K powder), Morphine hydrochloride; Add new samples if necessary |
Sampling | Dipstick tracking trace particles, and test strip wipe Sampling |
Database | can add new type explosive |
Alarm | Sound / light |
Sensitivity limit | 100 Nanogram TNT |