Labtron LLTT-A22 is manufactured with new-type compressor and has two cooling baths in one chamber. The instrument is specially designed and made as per ASTM D2386 Standard Test Method for Solidifying Point of Petroleum Products.
View CatalogTemperature controlling accuracy | ± 0.5 °C |
---|---|
Refrigeration system | New-type refrigeration compressor |
Cold trough | One trough with two baths, temperatures in two baths are equal |
Controlling temperature of cold trough | Room temperature ~ (-70) °C |
Temperature Range | 20 °C ~ 80 °C |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Dimensions | 730 x 580 x 520 mm |
Total power consumption | ≤ 1000 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
It is widely used in petroleum, chemical and research industry.
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Operation Mode | The outer barrel temperature is constant |
Temperature resolution | 0.0001°C |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Operation Mode | A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode |
Temperature resolution | 0.0001°C |
Calorimeter type | Isoperibol |
Oxygen filling | Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering |
Bomb volume | 250 ml |
Analysis time | < 8 min full test process: |
Bomb washing | Manual |
Calorimeter type | Isoperibol |
Oxygen filling | Semi-automatic |
Bomb volume | 282 ml |
Analysis time | 15 to 25 min |
Bomb washing | Manual |
Measuring Range For Aviation Gasoline | 86.0 to 105.0/MON |
Measuring Range For Gasoline For Motor Vehicles | National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON |
Measuring Range For Ethanol | E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON |
Measuring Range For Automobile Diesel Fuels | Cetane number: 25 to 75/CN Cetane index: 20 to 80/CI |
Measuring Accuracy | Aviation gasoline: ≤ ± 1.5/MON Gasoline for motor vehicles: ≤ ± 1.5/RON, ≤ ± 1.5/MO Automobile diesel fuels: ≤ ± 2.6/CN, ≤ ± 2.6/CI Regression sample retest: ≤ ± 0.5/RON, ≤ ± 0.5/MON Regression sample measurement: ≤ ± 1.5/RON, ≤ ± 1.5/MON Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON |
Measurement item | motor gasoline and diesel |
measurement unit of octane is ON | 40 to 120 |
Permissible error of octane | ± 0.5 max |
Fluctuate range of octane | ± 0.2 max |
measurement unit of cetane is CN | 20 to 100 |
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Ambient temperature | (-10 )°C to 35 °C |
Relative humidity | ≤ 85 % |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Precision of titration tube | Scale division is 0.02 ml |
Total power consumption | ≤ 1200 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Measurement range | ≥0.05 mg KOH/g |
Potential measurement range | 0 to 1800.0 mV |
Burette volume | 10 mL |
Minimum titration volume | 0.001 ml |
Burette precision | ±0.1 %FS |
Volumetric analysis | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml |
Automatic acid titration | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH |
Automatic potential control | Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV |
Ambient temperature | 0 ~ 35 ℃ |
Relative humidity | ≤ 85 % |
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Interior Dimension | 360 × 250 × 545 mm |
Exterior Dimension | 370 × 320 × 630 mm |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Power of motor | 2 kW |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Temperature range | 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C |
Aperture of ignition device | 0.8 mm |
Standard oil cup-Inner diameter | 50.7 ~ 50.8 mm |
Ambient temperature | 10 °C ~ 40 °C |
Relative humidity | ≤ 80 % |
Measurement Range | Ambient Temperature ~ 250 °C |
Flash Point | Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C |
Resolution | 0.1 °C |
Ambient temperature | 10 °C ~ 40 ℃ |
Relative humidity | ≤ 80 % |
Ignition Mode | electron igniter / gas flame |
Temperature range | Room Temperature ~ 300 ℃ |
Measurement Range | Room Temperature ~ 300 ℃ |
Ambient temperature | Room temperature to 35 °C |
Relative humidity | ≤ 85 % |
Timing range | 1 s to 9 min 59 s |
Temperature controlling range | Room temperature to 99.9 °C |
Temperature controlling accuracy | ± 1 °C |
Ambient temperature | Room temperature to 35 °C |
Relative humidity | ≤ 85 % |
Temperature controlling range | Room temperature to 99.9 °C |
Temperature controlling accuracy | ± 1 °C |
Stirring speed | 1500 ± 15 rpm |
Heating power | 2 kW |
Cooling power | 0.5 kW |
Steam temperature | 0 to 400℃ |
Oven temperature | 0 to 500℃ |
Refrigeration temperature | 0 to 60℃ |
Ambient temperature | -10°C to 35°C |
Relative humidity | ≤ 85 % |
Thermometer | Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C |
Scale division | 0.1 ℃ |
Total length | 8000 mm |
Graduated flasks | 100 ml |
Scale division of graduated flask | 1ml |
Distillation flask | 125 ml |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Graduated flasks | 100 ml |
Distillation flask | 125 ml |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Temperature controlling accuracy | ± 0.5 °C |
Beaker quantity | 600 ml |
Ambient temperature | (-10) °C ~ 40 °C |
Relative humidity | ≤ 85 % |
Thermometer Measurement range | (-5) °C ~ 300 °C |
Thermometer Scale division | 1 °C |
Ambient temperature | ≤ 35 ℃ |
Relative humidity | ≤ 85 % |
Heating power of electric furnace | 250 W × 2 |
Total power consumption | ≤ 700 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Graduated Flask | 200 ± 0.2 ml |
Standard Water Value | 51 ± 1 s |
Temperature Range | 0 ~ 100 °C |
Temperature Controlling Accuracy | ± 0.2 °C |
Accuracy Of Timer | 0.01 s |
Graduated Flask | 100 ml |
Standard Water Value | 51 ± 1 s |
Temperature Range | 0 ~ 100 °C |
Temperature Controlling Accuracy | ± 0.1 °C |
Accuracy Of Timer | 0.01 s |
Graduated Flask | 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials) |
Standard Water Value | 51 ± 1 s |
Temperature Range | 0 ~ 100 °C |
Ambient Temperature | 10 °C ~ 40 °C |
Temperature Controlling Accuracy | ± 0.1 °C |
Evaporation bath type and size | Aluminum block bath, φ260 × 130 mm |
Holes for testing | 3 pieces |
Size of holes for testing cylinder | φ51 × 70 mm |
Flow rate display | Flow meter |
Working temperature | 60 ℃ to 165 ℃ |
Evaporation bath type and size | Aluminum bath φ260 × 130 mm |
Holes for testing | 5 pieces |
Size of holes for testing cylinder | φ51 × 70 mm |
Working temperature | 160 ℃ ~ 165℃ |
Working pressure for decompression valve | 0.07 MPa |
Bath type | Oil bath |
Bath capacity | 5000 ml ± 50 ml |
Ambient temperature | Room temperature to 35 °C |
Relative humidity | ≤ 85 % |
Temperature controlling range | RT to 250 °C |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 11 pieces |
Stirring motor | 6 W, 1200 rpm |
Temperature controlling accuracy | ± 0.1 °C |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 11 pieces |
Stirring motor | 6 W, 1200 rpm |
Temperature controlling range | Ambient temperature ~ 100 °C |
Ambient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group |
Stirring motor | 6 W, 1200 rpm |
Sample quantity | 3 piece at the same time |
Ambient temperature | ≤ 30 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 13 pieces |
Stirring motor | 6 W, 1200 rpm |
Temperature controlling range | Ambient temperature ~ 70 °C |
Ambient temperature | (-10)℃ ~ 35 ℃ |
Relative humidity | ≤ 85 % |
Sample cup Inner diameter | 31.0 ~ 32.0 mm |
Sample cup Wall thickness | 1.0 ~ 1.5 mm |
Sample cup Height | 115 ~ 125 mm |
Temperature controlling accuracy | ± 0.5 ℃ |
Refrigeration system | New-type refrigeration compressor |
Cold trough | Two holes in one trough, and same temperature |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Refrigeration system | New-type refrigeration compressor |
Controlling temperature of cold trough | Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Inner Dimensions | 560 x 380 x 250 mm |
Refrigeration system | New-type refrigeration compressor |
Controlling temperature of cold trough | Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Dimensions | 930 x 570 x 108 mm |
Thermometer | 0 ℃ ~ 360 °C |
Scale Division | 1 °C |
Ambient Temperature | ≤ 35 °C |
Relative Humidity | ≤ 85 % |
Outer Crucible-Material | Carbon structural steel |
Thermometer | 6 ℃ ~ 400 ℃ |
Scale Division | 2 °C |
Spout Aperture | 0.6 ~ 0.8 mm |
Ambient Temperature | -10 ℃ ~ 50 ℃ |
Relative Humidity | ≤ 85 % |
Ambient Temperature | 10 ℃ ~ 40 ℃ |
Relative Humidity | ≤ 85 % |
Temperature Measurement- Full Scale | Ambient temperature to ~ 400 ℃ |
Temperature Measurement- Repeatability | ≤ 4 ℃ |
Test accuracy | 0.005 |
Ambient Temperature | 10 ℃ ~ 40 °C |
Relative Humidity | ≤ 80 % |
Temperature Measurement- Full Scale | Ambient temperature to 300 °C |
Temperature Measurement- Repeatability | ≤ 8 °C |
Temperature Measurement- Reproducibility | ≤ 16 °C |
Dimension | 390 x 260 x 590 mm |
Total power consumption | ≤ 1200 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
Heating power of water bath | 1000 W |
Relative humidity | ≤ 85 % |
Power supply | AC 220 V ± 10 %, 50 Hz |
Temperature controlling range in water bath | RT ~ 90 ℃ ± 5 ℃ |
Cooling bath temperature | (-35) ℃ ± 1 ℃ |
Evaporation temperature | 35 ℃ ± 1 ℃ |
Flow rate | 2 ~ 3 L / min |
Power supply | AC 220 V ± 5 % , 50Hz |
Measurement range | 0 ~ 75 kV |
Voltage rising rate | 3 kV ± 10 % / s |
Distance between electrodes | 2.5 mm |
Output power | 2 kVA |
Light source | 220 V, 100 W |
Temperature of grinding milk white light bulb | 2750 ± 50 K |
Light hole( Φ14) | 26 pieces |
Color comparing tube | Φ32 mm |
Dimension | 440 x 420 x 340 mm |
Samples | 2 |
Oil bath cubage | 30 L |
Angle between bomb and water surface | 30 ° |
Speed of rotary assembly | 100 ± 5 RPM |
Pressure sensor | 0 to 1.6 Mpa; Accuracy: ±2% |
Samples | 6 |
Temperature controlling mode | Automatic digital temperature |
Temperature controlling range | Room temperature ~ 160 °C |
Temperature controlling accuracy | ± 0.2 °C |
Power supply | 220 V, 50 Hz |
Samples | 8 |
Temperature | 100 ℃ |
Temperature controlling accuracy | 0.1 ℃ |
Flow meter | 3 ± 0.3 L / H oxygen |
Power supply | 220 V ± 10 %, 60 Hz |
Temperature Range | Ambient to 150℃ |
Temperature Precision | ± 0.1°C |
Test Unit | 2 units |
Heating Power | 1800 W |
Ambient Temperature | (Room temperature to 35°C |
Temperature controlling range | 10 ℃ ~ 35 ℃ |
Temperature resolution | 0.001 ℃ |
Mean value of heat capacity | 15 kJ / K |
Ambient temperature | 20 ℃ ± 5 ℃ |
Relative humidity | ≤ 85 % |
Temperature measurement range | 10 ~ 35 ℃ |
Repeatability error | ≤ 0.2 % (Grade C) |
Endured pressure in oxygen bomb | 20 MPa |
Operation environment temperature | 15 ~ 28 ℃ |
Temperature resolution | 0.001 ℃ |
Heat capacity | 14000 ~ 15000 J / K |
Temperature measurement range | 10 ~ 35 ℃ |
Repeatability error | ≤ 0.2 % (Grade C) |
Endured pressure in oxygen bomb | 20 MPa |
Operation environment temperature | 15 ~ 28 ℃ |
Porcelain crucible | 30 ml |
Inner iron crucible | 75 ml |
Outer iron crucible | 190 ml |
Burner | Mig Burner |
Dimensions | 400 x 380 x 270 mm |
Bath type | Four holes with a furnace |
Heating type | Electric resistance furnace |
Temperature controlling range | 0 ~ 520 °C |
Temperature controlling accuracy | ± 5 °C |
Relative humidity | ≤ 85 % |
Coking furnace | Metal furnace |
Heating mode | Electric heating |
Test unit | 5 units |
Temperature range | Ambient to 550°C |
Temperature precision | ≤ ± 5℃ |
Sample hole | 4 pieces |
Sample quantity | 4 to 12 pieces |
Ambient temperature | Room temperature to 35 °C |
Temperature controlling range | Room temperature to 100°C |
Temperature controlling accuracy | ± 1°C |
Sample hole | 2 pieces |
Speed of stirring motor | 1400 rpm |
Ambient temperature | 10 to 35°C |
Temperature controlling range | Room Temperature to 100°C |
Temperature controlling accuracy | ± 0.5°C |
Sample hole | 4 pieces |
Speed of stirring motor | 1400 rpm |
Speed for sample stirring | 1000 ± 50 rpm |
Ambient temperature | Room temperature to 35°C |
Temperature controlling range | 0 to 100°C |
Sample hole | 4 pieces |
Ambient temperature | Room temperature to 35°C |
Temperature controlling range | 0 to 100°C |
Temperature controlling accuracy | ± 1°C |
Relative humidity | ≤ 85 % |
Sample quantity | 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm) |
Measurement time | 60, 120, 240, 300, and 600 s at random |
Measurement range | 7 ppm to 5 % |
Repeatability | < 0.029 (S + 0.6) |
Reproducibility | < 0.063 (S + 0.6) |
Air flow rate | Not less than 150 L / h |
Max. Preset time | 99 min 59 s (100 min) |
Chamber diameter of oven | Φ22 mm |
Heating power of oven | 1400 W × 2 |
Max. Temperature of oven | 950 °C |
Operation temperature of water bath | RT ~ 90 °C |
Temperature controlling accuracy | ± 0.1 °C |
Dimensions | 550 × 520 × 102 mm |
Pressure meter accuracy | ± 0.4 % kPa |
Heating power of water bath | 1600 W |
Test bomb | Two samples or a group of parallel samples |
Bath temperature | 37.8 °C |
Temperature controlling accuracy | 0.1 °C |
Dimensions | 500 × 560 × 680 mm, 950 × 540 × 720 mm |
Heating power of water bath | 1400 W |
Ambient Temperature | 10°C to 35°C |
Measurement Range | 0 to 100 mg |
Resolution | 0.1 µg |
Max. Electrolysis Speed | 40 µg /s |
Amount and Precision of electrolysed water | 10 µg to 1000 µg, ± 2 µg and >1000 µg, 0.2 % |
Ambient Temperature Range | ≤ 35°C |
Relative Humidity | ≤ 85% |
Heating Mantle Cap Power | 1000 W |
Sample Determination | 1 at a time |
Dimension | 580 × 350 × 300 mm |
Ambient Temperature Range | ≤ 35°C |
Relative Humidity | ≤ 85% |
Heating Mantle Cap Power | 1000 W × 2 |
Sample Determination | 2 at a time |
Dimension | 690 × 570 × 310 mm |
Ambient Temperature Range | -10 to 35°C |
Relative Humidity | ≤85% |
Distillation Flask | 1000 ml |
Receiver | 5 ml, with 0.05 ml graduation |
Condenser | 400 mm with ± 5 mm accuracy |
Measurement range | 0 to 600 penetration scale |
Timing controller | 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec |
Time accuracy | ± 0.1 seconds |
Resolution | 0.01 mm |
Penetration accuracy | ± 1 penetration |
Measurement range | 0 to 600 penetration scale |
Timing controller | 5 sec or 60 sec |
Time accuracy | ± 0.1 seconds |
Resolution | 0.01 mm |
Penetration accuracy | ± 1 penetration |
Penetrometer |
|
Circulatory Water Bath |
|
Measurement range | 0 to 600 penetration scale |
Timing range | 0 sec to 60 sec |
Time accuracy error | ≥ ± 0.1 seconds |
Resolution | 0.1 penetration |
Power consumption | 200 W |