Low Temperature Tester :  Solidifying Point Tester ('-20°C +80°C') LLTT-A22

Solidifying Point Tester ('-20°C +80°C') LLTT-A22

Labtron LLTT-A22 is manufactured with new-type compressor and has two cooling baths in one chamber. The instrument is specially designed and made as per ASTM D2386 Standard Test Method for Solidifying Point of Petroleum Products.

View Catalog
Temperature controlling accuracy ± 0.5 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Temperature Range 20 °C ~ 80 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Dimensions 730 x 580 x 520 mm
Total power consumption ≤ 1000 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Integrated design for low temperature tester
  • Advance in design and reasonable in structure
  • Special temperature controlling techniques
  • Solidifying point determination from (-20) °C to 80 °C
  • Digital temperature system
  • High precision temperature sensor
  • Spray plastics for instrument shell process

It is widely used in petroleum, chemical and research industry.

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter : Automatic Bomb Calorimeter LABC-A10
Calorimeter typeIsoperibol
Temperature range5 to 40°C
Measurement range5 to 40 MJ/ kg
Operation ModeThe outer barrel temperature is constant
Temperature resolution0.0001°C

Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter : Automatic Bomb Calorimeter LABC-A11
Calorimeter typeIsoperibol
Temperature range5 to 40°C
Measurement range5 to 40 MJ/ kg
Operation ModeA. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Temperature resolution0.0001°C
Automatic Bomb Calorimeter LABC-B10
Automatic Bomb Calorimeter : Automatic Bomb Calorimeter LABC-B10
Calorimeter typeIsoperibol
Oxygen fillingFully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume250 ml
Analysis time< 8 min full test process:
Bomb washingManual
Automatic Bomb Calorimeter LABC-B11
Automatic Bomb Calorimeter : Automatic Bomb Calorimeter LABC-B11
Calorimeter typeIsoperibol
Oxygen fillingSemi-automatic
Bomb volume282 ml
Analysis time15 to 25 min
Bomb washingManual

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number & Cetane Number Tester : Octane Number and Cetane Number Tester LOCT-A10
 Measuring Range For Aviation Gasoline86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor VehiclesNational standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For EthanolE93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel FuelsCetane number: 25 to 75/CN Cetane index: 20 to 80/CI
Measuring AccuracyAviation gasoline: ≤ ± 1.5/MON Gasoline for motor vehicles: ≤ ± 1.5/RON, ≤ ± 1.5/MO Automobile diesel fuels: ≤ ± 2.6/CN, ≤ ± 2.6/CI Regression sample retest: ≤ ± 0.5/RON, ≤ ± 0.5/MON Regression sample measurement: ≤ ± 1.5/RON, ≤ ± 1.5/MON Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON

Portable Octane Number and Cetane Meter LOCT-A20

Octane Number & Cetane Number Tester : Portable Octane Number and Cetane Meter LOCT-A20
Measurement itemmotor gasoline and diesel
measurement unit of octane is ON40 to 120
Permissible error of octane± 0.5 max
Fluctuate range of octane± 0.2 max
measurement unit of cetane is CN20 to 100

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10

Acid and Alkali Tester : Water Soluble Acid and Alkali Tester LAAT-A10
Graduated flask100 ml,50 ml
Conical flask100ml
Separatory funnel250ml
Ambient temperature(-10 )°C to 35 °C
Relative humidity≤ 85 %

Acid Number and Acidity Tester LAAT-A11

Acid and Alkali Tester : Acid Number and Acidity Tester LAAT-A11
Ambient temperature≤ 35 °C
Relative humidity≤ 85 %
Precision of titration tubeScale division is 0.02 ml
Total power consumption≤ 1200 W
Power supplyAC 220 V ± 10 %, 50 Hz
Acid Number Tester LAAT-A12
Acid and Alkali Tester : Acid Number Tester LAAT-A12
Measurement range≥0.05 mg KOH/g
Potential measurement range0 to 1800.0 mV
Burette volume10 mL
Minimum titration volume0.001 ml
Burette precision±0.1 %FS
Base Number Tester LAAT-A13
Acid and Alkali Tester : Base Number Tester LAAT-A13
Volumetric analysisTitration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
Automatic acid titrationTitration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
Automatic potential controlTitration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Ambient temperature0 ~ 35 ℃
Relative humidity≤ 85 %

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Test Equipment : Aniline Point Tester LAPT-A10
Measurement rangeRoom temperature ~ 150°C
Stirring speed0 ~ 1200 r / min
Heating power25 W
Interior Dimension360 × 250 × 545 mm
Exterior Dimension370 × 320 × 630 mm

Aniline Point Tester LAPT-A11

Aniline Test Equipment : Aniline Point Tester LAPT-A11
Temperature controlling accuracy≤ 0.5 ℃
Temperature controlling rangeRoom temperature ~ 200 ℃
Power supply for illumination5 V
Power of motor2 kW

Closed Cup Flash Point Tester

PMCC Flash Point Tester LCFP-A10

Closed Cup Flash Point Tester : PMCC Flash Point Tester LCFP-A10
Ambient temperature≤ 35 °C
Relative humidity≤ 85 %
Temperature range5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device0.8 mm
Standard oil cup-Inner diameter50.7 ~ 50.8 mm

Automatic PMCC Flash Point Tester LCFP-A11

Closed Cup Flash Point Tester : Automatic PMCC Flash Point Tester LCFP-A11
Ambient temperature10 °C ~ 40 °C
Relative humidity≤ 80 %
Measurement RangeAmbient Temperature ~ 250 °C
Flash PointLower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Resolution0.1 °C
Automatic PMCC Flash Point Tester LCFP-A13
Closed Cup Flash Point Tester : Automatic PMCC Flash Point Tester LCFP-A13
Ambient temperature10 °C ~ 40 ℃
Relative humidity≤ 80 %
Ignition Modeelectron igniter / gas flame
Temperature rangeRoom Temperature ~ 300 ℃
Measurement RangeRoom Temperature ~ 300 ℃

Demulsibility Characteristics Tester

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

Demulsibility Characteristics Tester : Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
Ambient temperatureRoom temperature to 35 °C
Relative humidity≤ 85 %
Timing range1 s to 9 min 59 s
Temperature controlling rangeRoom temperature to 99.9 °C
Temperature controlling accuracy± 1 °C

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

Demulsibility Characteristics Tester : Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
Ambient temperatureRoom temperature to 35 °C
Relative humidity≤ 85 %
Temperature controlling rangeRoom temperature to 99.9 °C
Temperature controlling accuracy± 1 °C
Stirring speed1500 ± 15 rpm

Distillation Tester

Automatic Distillation Apparatus LADA-A10

Distillation Tester : Automatic Distillation Apparatus LADA-A10
Heating power2 kW
Cooling power0.5 kW
Steam temperature0 to 400℃
Oven temperature0 to 500℃
Refrigeration temperature0 to 60℃

Benzene Distillation Tester (Low Temperature) LDT-A11

Distillation Tester : Benzene Distillation Tester (Low Temperature) LDT-A11
Ambient temperature-10°C to 35°C
Relative humidity≤ 85 %
ThermometerEach one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division0.1 ℃
Total length8000 mm
Distillation Tester Dual Units LDT-A15
Distillation Tester : Distillation Tester Dual Units LDT-A15
Graduated flasks100 ml
Scale division of graduated flask1ml
Distillation flask125 ml
Ambient temperature≤ 35 °C
Relative humidity≤ 85 %
Distillation Tester (low temperature Double units) LDT-A16
Distillation Tester : Distillation Tester (low temperature Double units) LDT-A16
Graduated flasks100 ml
Distillation flask125 ml
Ambient temperature≤ 35 °C
Relative humidity≤ 85 %
Temperature controlling accuracy± 0.5 °C

Dropping Point Tester

Dropping Point Tester (Oil Bath) LDPT-A10

Dropping Point Tester : Dropping Point Tester (Oil Bath) LDPT-A10
Beaker quantity600 ml
Ambient temperature(-10) °C ~ 40 °C
Relative humidity≤ 85 %
Thermometer Measurement range(-5) °C ~ 300 °C
Thermometer Scale division1 °C

Dropping Point Tester (Air bath) LDPT-A11

Dropping Point Tester : Dropping Point Tester (Air bath) LDPT-A11
Ambient temperature≤ 35 ℃
Relative humidity≤ 85 %
Heating power of electric furnace250 W × 2
Total power consumption≤ 700 W
Power supplyAC 220 V ± 10 %, 50 Hz

Engler Viscometer

Engler Viscometer LEV-A10

Engler Viscometer : Engler Viscometer LEV-A10
Graduated Flask200 ± 0.2 ml
Standard Water Value51 ± 1 s
Temperature Range0 ~ 100 °C
Temperature Controlling Accuracy± 0.2 °C
Accuracy Of Timer0.01 s

Engler Viscometer LEV-A11

Engler Viscometer : Engler Viscometer LEV-A11
Graduated Flask100 ml
Standard Water Value51 ± 1 s
Temperature Range0 ~ 100 °C
Temperature Controlling Accuracy± 0.1 °C
Accuracy Of Timer0.01 s
Engler Viscometer LEV-B10
Engler Viscometer : Engler Viscometer LEV-B10
Graduated Flask200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value51 ± 1 s
Temperature Range0 ~ 100 °C
Ambient Temperature10 °C ~ 40 °C
Temperature Controlling Accuracy± 0.1 °C

Existent Gum Tester

Existent Gum Tester LEGT- B31

Existent Gum Tester : Existent Gum Tester LEGT- B31
Evaporation bath type and sizeAluminum block bath, φ260 × 130 mm
Holes for testing3 pieces
Size of holes for testing cylinderφ51 × 70 mm
Flow rate displayFlow meter
Working temperature60 ℃ to 165 ℃

Existent Gum Tester LEGT- B32

Existent Gum Tester : Existent Gum Tester LEGT- B32
Evaporation bath type and sizeAluminum bath φ260 × 130 mm
Holes for testing5 pieces
Size of holes for testing cylinderφ51 × 70 mm
Working temperature160 ℃ ~ 165℃
Working pressure for decompression valve0.07 MPa
Existent Gum Tester LEGT- B30
Existent Gum Tester : Existent Gum Tester LEGT- B30
Bath typeOil bath
Bath capacity5000 ml ± 50 ml
Ambient temperatureRoom temperature to 35 °C
Relative humidity≤ 85 %
Temperature controlling rangeRT to 250 °C

Kinematics Viscometer

Kinematics Viscometer LKV-A11

Kinematics Viscometer : Kinematics Viscometer LKV-A11
Ambient temperature(-10) °C ~ 35 °C
Relative humidity≤ 85 %
Capillary viscometer11 pieces
Stirring motor6 W, 1200 rpm
Temperature controlling accuracy± 0.1 °C

Kinematics Viscometer LKV-A12

Kinematics Viscometer : Kinematics Viscometer LKV-A12
Ambient temperature(-10) °C ~ 35 °C
Relative humidity≤ 85 %
Capillary viscometer11 pieces
Stirring motor6 W, 1200 rpm
Temperature controlling rangeAmbient temperature ~ 100 °C
Kinematics Viscometer LKV-A13
Kinematics Viscometer : Kinematics Viscometer LKV-A13
Ambient temperature(-10) °C ~ 35 °C
Relative humidity≤ 85 %
Capillary viscometer7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor6 W, 1200 rpm
Sample quantity3 piece at the same time
Low Temperature Kinematic Viscosity Tester LKV-A14
Kinematics Viscometer : Low Temperature Kinematic Viscosity Tester LKV-A14
Ambient temperature≤ 30 °C
Relative humidity≤ 85 %
Capillary viscometer13 pieces
Stirring motor6 W, 1200 rpm
Temperature controlling rangeAmbient temperature ~ 70 °C

Low Temperature Tester

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

Low Temperature Tester : Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
Ambient temperature(-10)℃ ~ 35 ℃
Relative humidity≤ 85 %
Sample cup Inner diameter31.0 ~ 32.0 mm
Sample cup Wall thickness1.0 ~ 1.5 mm
Sample cup Height115 ~ 125 mm

Solidifying Point Tester LLTT-A13

Low Temperature Tester : Solidifying Point Tester LLTT-A13
Temperature controlling accuracy± 0.5 ℃
Refrigeration systemNew-type refrigeration compressor
Cold troughTwo holes in one trough, and same temperature
Ambient temperature≤ 30 ℃
Relative humidity≤ 85 %
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
Low Temperature Tester : Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
Refrigeration systemNew-type refrigeration compressor
Controlling temperature of cold troughCold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature≤ 30 ℃
Relative humidity≤ 85 %
Inner Dimensions560 x 380 x 250 mm
Multifunctional Low Temperature Tester LLTT-A16
Low Temperature Tester : Multifunctional Low Temperature Tester LLTT-A16
Refrigeration systemNew-type refrigeration compressor
Controlling temperature of cold troughCold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature≤ 30 ℃
Relative humidity≤ 85 %
Dimensions930 x 570 x 108 mm

Open Cup Flash Point Tester

Open Cup Flash Point Tester LOFP-A10

Open Cup Flash Point Tester : Open Cup Flash Point Tester LOFP-A10
Thermometer0 ℃ ~ 360 °C
Scale Division1 °C
Ambient Temperature≤ 35 °C
Relative Humidity≤ 85 %
Outer Crucible-MaterialCarbon structural steel

Cleveland Open Cup Flash Point Tester LOFP-A11

Open Cup Flash Point Tester : Cleveland Open Cup Flash Point Tester LOFP-A11
Thermometer6 ℃ ~ 400 ℃
Scale Division2 °C
Spout Aperture0.6 ~ 0.8 mm
Ambient Temperature-10 ℃ ~ 50 ℃
Relative Humidity≤ 85 %
Automatic COC Flash & Fire Point Tester LOFP-B10
Open Cup Flash Point Tester : Automatic COC Flash & Fire Point Tester LOFP-B10
Ambient Temperature10 ℃ ~ 40 ℃
Relative Humidity≤ 85 %
Temperature Measurement- Full ScaleAmbient temperature to ~ 400 ℃
Temperature Measurement- Repeatability≤ 4 ℃
Test accuracy0.005
Automatic Cleveland Open Cup Flash Point Tester LOFP-A12
Open Cup Flash Point Tester : Automatic Cleveland Open Cup Flash Point Tester LOFP-A12
Ambient Temperature10 ℃ ~ 40 °C
Relative Humidity≤ 80 %
Temperature Measurement- Full ScaleAmbient temperature to 300 °C
Temperature Measurement- Repeatability≤ 8 °C
Temperature Measurement- Reproducibility≤ 16 °C

Other Instrument

Mechanical Impurity Tester (Weight Method) LMIT-A21

Other Instrument : Mechanical Impurity Tester (Weight Method) LMIT-A21
Dimension390 x 260 x 590 mm
Total power consumption≤ 1200 W
Power supplyAC 220 V ± 10 %, 50 Hz
Heating power of water bath1000 W
Relative humidity≤ 85 %

Wax Oil Content Tester LWCT-A22

Other Instrument : Wax Oil Content Tester LWCT-A22
Power supplyAC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bathRT ~ 90 ℃ ± 5 ℃
Cooling bath temperature(-35) ℃ ± 1 ℃
Evaporation temperature35 ℃ ± 1 ℃
Flow rate2 ~ 3 L / min
Insulating Oil Breakdown Voltage Tester LIBT-A23
Other Instrument : Insulating Oil Breakdown Voltage Tester LIBT-A23
Power supplyAC 220 V ± 5 % , 50Hz
Measurement range0 ~ 75 kV
Voltage rising rate3 kV ± 10 % / s
Distance between electrodes2.5 mm
Output power2 kVA
Color Tester LCT-A20
Other Instrument : Color Tester LCT-A20
Light source220 V, 100 W
Temperature of grinding milk white light bulb2750 ± 50 K
Light hole( Φ14)26 pieces
Color comparing tubeΦ32 mm
Dimension440 x 420 x 340 mm

Oxidation Stability Tester

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

Oxidation Stability Tester : Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
Samples2
Oil bath cubage30 L
Angle between bomb and water surface30 °
Speed of rotary assembly100 ± 5 RPM
Pressure sensor0 to 1.6 Mpa; Accuracy: ±2%

Transformer Oil Oxidation Stability Tester LOST-D11

Oxidation Stability Tester : Transformer Oil Oxidation Stability Tester LOST-D11
Samples6
Temperature controlling modeAutomatic digital temperature
Temperature controlling rangeRoom temperature ~ 160 °C
Temperature controlling accuracy± 0.2 °C
Power supply220 V, 50 Hz
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
Oxidation Stability Tester : Distillate Fuel Oil Oxidation Stability Tester LOST-D12
Samples8
Temperature100 ℃
Temperature controlling accuracy0.1 ℃
Flow meter3 ± 0.3 L / H oxygen
Power supply220 V ± 10 %, 60 Hz
Oxidation Stability Tester (Lubricating Grease) LOST-D20
Oxidation Stability Tester : Oxidation Stability Tester (Lubricating Grease) LOST-D20
Temperature RangeAmbient to 150℃
Temperature Precision± 0.1°C
Test Unit2 units
Heating Power1800 W
Ambient Temperature(Room temperature to 35°C

Oxygen Bomb Calorimeter

Oxygen Bomb Calorimeter LBC-C21

Oxygen Bomb Calorimeter : Oxygen Bomb Calorimeter LBC-C21
Temperature controlling range10 ℃ ~ 35 ℃
Temperature resolution0.001 ℃
Mean value of heat capacity15 kJ / K
Ambient temperature20 ℃ ± 5 ℃
Relative humidity≤ 85 %

Oxygen Bomb Calorimeter LBC-C22

Oxygen Bomb Calorimeter : Oxygen Bomb Calorimeter LBC-C22
Temperature measurement range10 ~ 35 ℃
Repeatability error≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb20 MPa
Operation environment temperature15 ~ 28 ℃
Temperature resolution0.001 ℃
Oxygen Bomb Calorimeter LBC-C20
Oxygen Bomb Calorimeter : Oxygen Bomb Calorimeter LBC-C20
Heat capacity14000 ~ 15000 J / K
Temperature measurement range10 ~ 35 ℃
Repeatability error≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb20 MPa
Operation environment temperature15 ~ 28 ℃

Residue Carbon

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

Residue Carbon : Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
Porcelain crucible30 ml
Inner iron crucible75 ml
Outer iron crucible190 ml
BurnerMig Burner
Dimensions400 x 380 x 270 mm

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

Residue Carbon : Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11
Bath typeFour holes with a furnace
Heating typeElectric resistance furnace
Temperature controlling range0 ~ 520 °C
Temperature controlling accuracy± 5 °C
Relative humidity≤ 85 %
Carbon Residue Tester (Ramsbottom) LRCT-B20
Residue Carbon : Carbon Residue Tester (Ramsbottom) LRCT-B20
Coking furnaceMetal furnace
Heating modeElectric heating
Test unit5 units
Temperature rangeAmbient to 550°C
Temperature precision≤ ± 5℃

Rust and Corrosion Tester

Copper Strip Corrosion Tester LRCT-A13

Rust and Corrosion Tester : Copper Strip Corrosion Tester LRCT-A13
Sample hole4 pieces
Sample quantity4 to 12 pieces
Ambient temperatureRoom temperature to 35 °C
Temperature controlling rangeRoom temperature to 100°C
Temperature controlling accuracy± 1°C

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

Rust and Corrosion Tester : Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10
Sample hole2 pieces
Speed of stirring motor1400 rpm
Ambient temperature10 to 35°C
Temperature controlling rangeRoom Temperature to 100°C
Temperature controlling accuracy± 0.5°C
Lubricating Oil Rust Characteristics Tester LRCT-A11
Rust and Corrosion Tester : Lubricating Oil Rust Characteristics Tester LRCT-A11
Sample hole4 pieces
Speed of stirring motor1400 rpm
Speed for sample stirring1000 ± 50 rpm
Ambient temperatureRoom temperature to 35°C
Temperature controlling range0 to 100°C
Rust Characteristics and Corrosion Tester LRCT-A12
Rust and Corrosion Tester : Rust Characteristics and Corrosion Tester LRCT-A12
Sample hole4 pieces
Ambient temperatureRoom temperature to 35°C
Temperature controlling range0 to 100°C
Temperature controlling accuracy± 1°C
Relative humidity≤ 85 %

Sulphur Content Tester

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

Sulphur Content Tester : X-ray Fluorescence Sulfur in Oil Analyzer LST-A10
Sample quantity2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time60, 120, 240, 300, and 600 s at random
Measurement range7 ppm to 5 %
Repeatability< 0.029 (S + 0.6)
Reproducibility< 0.063 (S + 0.6)

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

Sulphur Content Tester : Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11
Air flow rateNot less than 150 L / h
Max. Preset time99 min 59 s (100 min)
Chamber diameter of ovenΦ22 mm
Heating power of oven1400 W × 2
Max. Temperature of oven950 °C

Vapor Pressure

Vapor Pressure Tester (REID METHOD) LVPT-C10

Vapor Pressure : Vapor Pressure Tester (REID METHOD)  LVPT-C10
Operation temperature of water bathRT ~ 90 °C
Temperature controlling accuracy± 0.1 °C
Dimensions550 × 520 × 102 mm
Pressure meter accuracy± 0.4 % kPa
Heating power of water bath1600 W

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

Vapor Pressure : Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
Test bombTwo samples or a group of parallel samples
Bath temperature37.8 °C
Temperature controlling accuracy0.1 °C
Dimensions500 × 560 × 680 mm, 950 × 540 × 720 mm
Heating power of water bath1400 W

Water Content Tester

Coulometric Karl Fischer Titrator LWT-A30

Water Content Tester : Coulometric Karl Fischer Titrator LWT-A30
Ambient Temperature10°C to 35°C
Measurement Range0 to 100 mg
Resolution0.1 µg
Max. Electrolysis Speed40 µg /s
Amount and Precision of electrolysed water10 µg to 1000 µg, ± 2 µg and >1000 µg, 0.2 %

Water Content Tester LWT-A10

Water Content Tester : Water Content Tester LWT-A10
Ambient Temperature Range≤ 35°C
Relative Humidity≤ 85%
Heating Mantle Cap Power1000 W
Sample Determination1 at a time
Dimension580 × 350 × 300 mm
Water Content Tester LWT-A11
Water Content Tester : Water Content Tester LWT-A11
Ambient Temperature Range≤ 35°C
Relative Humidity≤ 85%
Heating Mantle Cap Power1000 W × 2
Sample Determination2 at a time
Dimension690 × 570 × 310 mm
Crude Petroleum Water Content Tester LWT-B10
Water Content Tester : Crude Petroleum Water Content Tester LWT-B10
Ambient Temperature Range-10 to 35°C
Relative Humidity≤85%
Distillation Flask1000 ml
Receiver5 ml, with 0.05 ml graduation
Condenser400 mm with ± 5 mm accuracy

Penetrometer

Penetrometer LMPT-A10

Penetrometer : Penetrometer LMPT-A10
Measurement range0 to 600 penetration scale
Timing controller5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy± 0.1 seconds
Resolution0.01 mm
Penetration accuracy± 1 penetration

Penetrometer LMPT-A11

Penetrometer : Penetrometer LMPT-A11
Measurement range0 to 600 penetration scale
Timing controller5 sec or 60 sec
Time accuracy± 0.1 seconds
Resolution0.01 mm
Penetration accuracy± 1 penetration
Penetrometer LMPT-A12
Penetrometer : Penetrometer LMPT-A12
Penetrometer
Measurement range0 to 600 penetration scale
Timing controller5 sec or 60 sec
Time accuracy± 0.1 seconds
Resolution0.1 penetration
Penetration accuracy± 1 penetration
Weight of standard needle2.5 ± 0.05 g
Dimensions (W × L × H)700 × 400 × 750 mm
Weight30 kg
Circulatory Water Bath
Bath volume3.5 L
Temperature range5 °C to 60 °C
Temperature accuracy± 0.1 °C
Circulatory water quantity3 L/minute
Pump Lift2 m
Power consumption1200 W
Power supplyAC 220V ± 10 %, 50 Hz
Dimensions (W × L × H)600 × 400 × 650 mm
Weight40 kg
Penetrometer LMPT-A13
Penetrometer : Penetrometer LMPT-A13
Measurement range0 to 600 penetration scale
Timing range0 sec to 60 sec
Time accuracy error≥ ± 0.1 seconds
Resolution0.1 penetration
Power consumption200 W