Carton compression tester TP-I11 with 100 mm/min return speed level measures the compressive strength of carton box. The compressor tester, adopted with ARM chip, powerful data functioning system, advanced sensor and automatic tracking system for test operations. The test results are recorded automatically, the real-time display is used to view the test data and is transferrable to computer.
View CatalogMeasuring range | 1 to 50 kN |
---|---|
Indication error | < ± 1% |
Platen Size | 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized) |
Operating stroke | 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized) |
Compression speed | 10 mm/ min |
Speed adjustment range | 2 to 100 mm/ min |
Track & force speed in stacking test | 2 mm/ min |
Power supply | AC220 V ± 10 % , 50 Hz |
Carton compression tester is used to determine compression strength & estimate stacking test of transport packages such as corrugated carton, paperboard box etc.
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Accuracy | Chromaticity co-ordinate 0.0001 |
Repeatability | Rx, Ry and Rz s ≤ 0.1 chromaticity co-ordinate s ≤ 0.0010, R457 s ≤ 0.10 |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
Zero drift | ≤ 0.1 % |
Indication drift | ≤ 0.1 % |
Sample (size) length | 38×70 mm |
Measuring range | (1-500) mN.m (divided into 7 small ranges) |
Indication error | 0.02 |
Test speed | (200° ± 20°)/ min |
Dimension (L*W*H) | 220 × 230 × 350 mm |
Sample (size) length | 90 to 200 mm |
Sample width | 15 mm, 25 mm, 50mm |
Measuring range | 0 to 30, 0 to 100 N,0 to 300 N |
Accuracy | ± 1 % |
Tensile strength velocity | 1 to 399 mm/min (adjustable) |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Rotate speed of the turntable | 11 r/min to 12r/min, turntable dimension diameter: 285 mm |
Quantity of heaters | 2 pcs |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
Vacuum chamber effective size | 270 × 210 mm |
Vacuum chamber size | 300 × 350 mm |
Resolution | 0.1 % O2 |
Measuring range | 0 to 100 % O2 |
Precision | ± 0.4 % O2 |
Response time | < 10 S |
Display precision | 0.1 ± 1 % |
Temperature range | 10 to 35°C |
Maximum falling height | 2000 mm |
Resolution of displacement | 1 mm |
Height error | < ± 2 mm |
Hammer mass | 0.25 to 16 kg |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Max dimension L × W × H | 910 × 510 × 860 mm |
Effective test space of the chamber L × W × H | 280 × 170 × 120 mm |
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Display | LED display |
Heater | Cylindrical mold |
Test arm weight | 2.5 N |
Additional Loads | 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N, |
Idler | 150 mm |
Abrasion stroke | 40 ± 0.2 M |
Horizontal displacement | 4.2 mm/ rotation |
Control temperature range | Normal temperature to 200°C |
Temperature display resolution | 0.01°C |
Temperature control accuracy | ± 0.3° |
Calibration accuracy | Mooney value ± 0.5 |
Rotor speed | 2 rpm |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Hardness indication | Analogue display |
Resolution | 0.5 HR |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Hardness indication | Digital display |
Resolution | 0.1 HR |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Brinell hardness test | 306, 613, 1839 N |
Vickers hardness test | 294, 588, 980 N |
Magnification of Microscope | 37.575 x |
Test force | 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N |
Hardness value symbol | HV1, HV5, HV10, HV20, HV30, HV250 |
Error range in display | ± 3.0 %, ± 2.0 % |
Hardness indication | Digital display |
Hardness value range in Measure | 5 HV to 2500 HV |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) |
Linearity error |
Repeatability error | A (absorbency of light) |
Wavelength range | Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) |
Linearity error |
Repeatability error | A (absorbency of light) |
Wavelength range | Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm |
Salinity Measurement range | 0.00 to 19.99 ms/cm |
Measuring accuracy | EC ± 2% full scale |
Temperature Measurement range | -5 to 50°C |
Temperature accuracy | ± 0.5°C |
Temperature compensation | 0 to 50°C |
Measuring range | 0 to 100 kPa |
Resolution | 0.01 kPa |
Accuracy | ± 1 kPa |
Soil temperature measuring range | -55 to 105°C |
Temperature accuracy | ± 1°C |