Plasma autoclave LPA-B12 comes with sliding door, rectangular chamber design, microprocessor PLC controlled system and 220 L volume capacity. Adopted with excellent thermal conductivity ensures 100% maintenance of gaseous hydrogen peroxide. Equipped with high and low temperature alarm system, pressure and temperature sensors, H2O2 resistant rotary vane vacuum pump for quality performance. The maximum storage space is obtained by loading items on the two layers of aluminum alloy punching plate.
View CatalogChamber Volume | 220 L |
---|---|
Sterilization temperature | 50 ± 5°C |
Working pressure | -50 Pa |
Sterilizing agent | 60 % (H2O2) hydrogen peroxide |
Sterilizing time | 45 to 50 min |
Installation environment temperature | 5 to 45°C |
Vacuum speed | Absorb to – 50 Pa in five minutes |
High anti-pressure valve | 10 Pa |
Door type | Rectangular type, sliding door |
Operation height (for chamber design) | ≤ 160 cm |
Chamber material | Anti-corrosion type SUS 304 stainless steel |
Chamber temperature heating power | 2.75 kW, pre-heating time 30 mins |
Electrode material | Anti-corrosion type SUS 304 stainless steel |
Sealing door material | Anti-corrosion type SUS 304 stainless steel |
Carton material | Carbon steel baking plastic powder and ABS |
Storage U disk capacity | ≥ 8 G |
Air filter accuracy | ≤ 0.2 µm |
Chamber dimension (L*W*H) | 820 × 510 × 460 mm |
Packaging dimension (L*W*H) | 1070 × 810 × 1780 mm |
Power | 5.15 kW |
Power supply | heating method AC220 V, 50 Hz |
Gross weight | 450 kg |
Used in the hospital, pharmaceutical factory, lab, medical institutions for low temperature sterilization of heat sensitive materials.
Accessories No. | Name |
1 | Hydrogen Peroxide (6-10 g/ bottle) |
2 | Indicative tape (20 × 25 mm/ roll) |
3 | Biological indicator (25 pieces/ box) |
4 | Chemical indicative card (200 pieces/ box) |
5 | Chemical indicative label |
6 | Sterilization packing bag |
7 | Non-woven fabrics |
Labtron compact Table Top Autoclave offer maximum performance in minimum space with capacity of up to 50 L. Provide quick and effective sterilization cycles at 134 °C. Include automatic shutoff, cold air discharge, over-temperature, and over-pressure protection for safe operation. With many features, ergonomic design and superior construction, they ensure reliable and consistent sterilization. Our Table Top Autoclave adopt high-efficiency low noise vacuum system for smooth functioning.
Capacity | 24 L |
Sterilization Temperature | 134 °C |
Adjustment temperature | 105 to 134 °C |
Sterilization Pressure | 0.22 MPa |
Number of sterilizing baskets | 3 |
Capacity | 35 L |
Sterilization Temperature | 134 °C |
Adjustment temperature | 105 to 134 °C |
Sterilization Pressure | 0.22 MPa |
Number of sterilizing baskets | 4 |
Capacity | 50 L |
Sterilization Temperature | 134 °C |
Adjustment temperature | 105 to 134 °C |
Sterilization Pressure | 0.22 MPa |
Number of sterilizing baskets | 4 |
Capacity | 24 L |
Sterilization Temperature | 134 °C |
Adjustment temperature | 105 to 134 °C |
Sterilization Pressure | 0.22 MPa |
Number of sterilizing baskets | 3 |
Labtron Vertical Autoclave are fully automatic, delivering easy and reliable sterilization cycles. They feature a space-efficient cylindrical design for up to 150 L capacity and simplify filling and cleaning process. Built-in features like pressure valves, thermostats, and a double-locking device have enhanced operational safety. Their high-precision microprocessor control system ensures optimal sterilization results. Our Vertical Autoclave are ideal for laboratories, hospitals, small clinics, and food and beverage units.
Capacity | 35 L |
Sterilization Temperature | 134 °C |
Sterilization Pressure | 0.22 Mpa |
Chamber Dimension ( Φ × D ) | 318 × 450 mm |
Timer Range | 0 - 60 min |
Capacity | 50 L |
Sterilization Temperature | 134 °C |
Sterilization Pressure | 0.22 Mpa |
Chamber Dimension ( Φ × D ) | 340 × 550 mm |
Timer Range | 0 - 60 min |
Capacity | 75 L |
Sterilization Temperature | 134 °C |
Sterilization Pressure | 0.22 Mpa |
Chamber Dimension ( Φ × D ) | 400 × 600 mm |
Timer Range | 0 - 60 min |
Capacity | 100 L |
Sterilization Temperature | 134 °C |
Sterilization Pressure | 0.22 Mpa |
Chamber Dimension ( Φ × D ) | 440 × 650 mm |
Timer Range | 0 - 60 min |
Labtron Horizontal Autoclave maintain consistent temperature up to 139 °C for effective sterilization. Their cylindrical or horizontal chambers provide optimal processing for capacities from 12 to 2000 L. Feature digital temperature controller, automatic pressure control switch and automatic sterilization cycles for seamless operation. Their durable stainless-steel construction ensures uniform and rapid pre-heating. Our Horizontal Autoclave are ideal for delivering high-performance and safe large-volume sterilization.
Capacity | 120 L |
Working temperature | 105 °C to 134 °C |
Sterilization temperature | 139 °C |
Sterilization pressure | 0.245 MPa |
Working pressure | 0.22 MPa |
Capacity | 300 L |
Sterilization Temperature | 134 °C |
Sterilization Pressure | 0.22 Mpa |
Timer Range | 0 - 99 minutes |
Heat Average | ≤ ± 1 ℃ |
Capacity | 500 L |
Sterilization Temperature | 134 °C |
Sterilization Pressure | 0.22 Mpa |
Timer Range | 0 - 99 minutes |
Heat Average | ≤ ± 1 ℃ |
Capacity | 150 L |
Sterilization Temperature | 134 °C |
Sterilization Pressure | 0.22 MPa |
Timer Range | 0 - 60 minutes |
Heat Average | ≤ ± 1 ℃ |
Labtron Medical Autoclave integrate advanced technology to deliver rapid and thorough sterilization of materials and medical waste. They come with multiple tray options to hold sterilized items up to 23 L capacity. Constructed from a range of materials, they ensure effective sterilization at 134 °C. Feature automated cycles, precise temperature control and enhanced safety mechanisms to streamline operation. Categorized under class B and class N, our Medical Autoclave are suitable for broad spectrum of medical applications.
Capacity | 14 L |
Sterilization Time | 4 - 18 mins |
Sterilization Temperature | 121 °C / 134 °C |
No. of Trays | 3 |
Dry Procedure | Vacuum drying |
Capacity | 17 L |
Sterilization Time | 4 - 18 mins |
Sterilization Temperature | 121 °C / 134 °C |
No. of Trays | 3 |
Dry Procedure | Vacuum drying |
Capacity | 23 L |
Sterilization Time | 4 - 18 mins |
Sterilization Temperature | 121 °C / 134 °C |
No. of Trays | 3 |
Dry Procedure | Vacuum drying |
Capacity | 14 L |
Sterilization Time | 4 - 20 mins |
Sterilization Temperature | 121 °C / 134 °C |
No. of Trays | 2 |
Chamber Dimension ( Φ × D ) | 250 × 280 mm |
Labtron Plasma Autoclave employ deep hydrogen-peroxide penetration for efficient sterilization under low pressure and temperature conditions. They offer 240 L sterilization capacity for heat & moisture sensitive equipment. Their ergonomic design and alarm systems ensure operational safety. They have advanced and flexible controllers that increase sterilization efficiency and shorten cycle times. These eco-friendly Plasma Autoclave find applications in hospitals, pharmaceuticals, laboratories and medical facilities.
Capacity | 80 L |
Door type | Rectangular, single door |
Chamber material | Anti rust aluminum alloy |
Power supply | 3 kW / 220 V, Single phase |
Sterilizing agent | 60 % H2O2 |
Capacity | 120 L |
Door type | Rectangular, single door |
Chamber material | Anti rust aluminum alloy |
Power supply | 3 kW / 220 V, Single phase |
Sterilizing agent | 60 % H2O2 |
Capacity | 240 L |
Door type | Rectangular, double door |
Chamber material | Anti rust aluminum alloy |
Power supply | 3 kW / 220 V, Single phase |
Sterilizing agent | 60 % H2O2 |
Chamber Volume | 100 L |
Sterilization temperature | 50 ± 5°C |
Working pressure | -50 Pa |
Sterilizing agent | 60 % (H2O2) hydrogen peroxide |
Sterilizing time | 45 to 50 min |
Labtron Portable Autoclave provide optimum steam conditions at 126 °C temperature for efficient sterilization. These compact electric heated units are ideal for sterilizing small batches of samples. Their intuitive interface facilitates easy customization of sterilization cycles. They include safety devices for protection from overpressure or any accidents. Our robust Portable Autoclave are simple to use in diverse areas like bacteriological and research laboratories, and dental and pharmaceutical industries.
Volume of Chamber | 18 L |
Working temperature | 126 ℃ |
Heating mode | Electrically / LPG heated |
Working pressure | 0.14 ~ 0.16 MPa |
Max safety pressure | 0.165 MPa |
Volume of Chamber | 24 L |
Working temperature | 126 ℃ |
Heating mode | Electrically / LPG heated |
Working pressure | 0.14 ~ 0.16 MPa |
Max safety pressure | 0.165 MPa |
Volume of Chamber | 18 L |
Working temperature | 126 ℃ |
Heating mode | Electrically heated |
Working pressure | 0.14 ~ 0.16 MPa |
Max safety pressure | 0.165 MPa |
Volume of Chamber | 24 L |
Working temperature | 126 ℃ |
Heating mode | Electrically heated |
Working pressure | 0.14 ~ 0.16 MPa |
Max safety pressure | 0.165 MPa |
Labtron Ethylene Oxide Sterilizer operate at low temperature of 50 °C ensuring effective and efficient sterilization. They utilize ethylene gas and are compatible with wide range of medical device materials. Equipped with advanced controller for precise regulation of gas concentration and exposure time. They adhere to regulatory standards for optimal safety and efficacy. Our Ethylene Oxide Sterilizers penetrate packaging and plastic without causing damage, making them suitable for healthcare facilities.
Type | Vertical; constant temperature heating box type |
Door opening | Manual |
Capacity | 80 L |
Sterilization temperature | 50℃ ± 3℃ |
Work pressure | -60 kPa |
Type | Vertical; constant temperature heating box type |
Door opening | Manual |
Capacity | 120 L |
Sterilization temperature | 50℃ ± 3℃ |
Work pressure | -60 kPa |
Type | Vertical; constant temperature heating box type |
Door opening | Manual |
Capacity | 220 L |
Sterilization temperature | 50℃ ± 3℃ |
Work pressure | -60 kPa |
Type | Vertical; constant temperature heating box type |
Door opening | Manual |
Capacity | 360 L |
Sterilization temperature | 50℃ ± 3℃ |
Work pressure | -60 kPa |