Automatic Potentiometric Titrator LPTT-A10

Automatic Potentiometric Titrator LPTT-A10 is an automatic titrator with integrated burette valve design. This modular titrator consist of three units: volume titration device, control device, measurement device. The titration analysis includes acid-base titration, oxidation-reduction titration, non-aqueous, precipitation titration and others.

Titration mode Macro titration, Micro titration, Volume setting titrations, End point titration, Stored titration
Analysis method Acid-base Titration, Oxidation-reduction titration, Precipitation titration, Complexometric, Non-aqueous titration
Measurement Range
  • pH value: 0.00 to 14.00
  • mV value: -1999.0 to 1999.0 mV
  • Temperature value: 0 to 100 °C
Resolution
  • pH value: 0.04 pH
  • mV value: 0.1 mV
  • Temperature value: 0.1°C
Accuracy
  • pH value: ± 0.02 pH
  • mV value: ± 0.2 mV
  • Temperature value: 0.2°C
Burette Volume Accuracy
  • 15 ml burette: ± 0.025 ml
  • 25 ml burette: ± 0.035 ml
  • Titration analysis parallelism: 0.002
  • Millivolt accuracy: ≤ 0.2 mV
Stir Coil realize Magnetism stir
Titration cup 100 ml
Electrodes port type mV, pH 1, reference electrode 1, PT1000 electrode 1
Display 7 inch TFT touch screen display
Communication port USB, Stir port, power port, printer port
Learn titration Methods can be edited and stored
Power supply 110 to 240 V, 50/60 Hz
External dimension 530 × 455 × 280 mm
Net Weight 10 kg
  • Equipped with Ultrathin stirring device
  • Zero dead volume solenoid valve
  • 7 inch LCD touch screen display
  • Titration end point reminder
  • Wide operating voltage range
  • User friendly operations

Used in performing iodine peroxide titration and other titration methods in food industry. Also it finds application in pharma, chemical, petrochemical, life science industry.

Measurement Range pH: (0.00 to 14.00) pH<br/>mV: (-1800.0 to 1800.0) mV<br/>Temp: (-5.0 to 105.0)°C
Resolution pH: 0.01 pH; mV: 0.1 mV; Temp: 0.1°C
Accuracy pH: ± 0.01 pH ± 1 bit<br/>mV: ± 0.03 % (full scale)<br/>Temp: ± 0.3°C
Accuracy Of Burette Volume 10 ml burette: ± 0.025 ml<br/>20 ml burette: ± 0.035 ml
Measurement Range pH: (0.00 to 14.00) pH<br/>mV: (-1800.0 to 1800.0) mV<br/>Temp: (-5.0 to 105.0)°C
Resolution pH: 0.01 pH; mV: 0.1 mV; Temp: 0.1°C
Accuracy pH: ± 0.01 pH ± 1 bit<br/>mV: ± 0.03 % (full scale)<br/>Temp: ± 0.3°C
Accuracy Of Burette Volume 10 ml burette: ± 0.025 ml<br/>20 ml burette: ± 0.035 ml
Titration mode Macro titration, Micro titration, Volume setting titrations, End point titration, Stored titration
Analysis method Acid-base Titration, Oxidation-reduction titration, Precipitation titration, Complexometric, Non-aqueous titration
Measurement Range
pH value 0.00 to 14.00
mV value -1999.0 to 1999.0 mV
Temperature value 0 to 100 °C
Resolution
pH value 0.04 pH
mV value 0.1 mV
Temperature value 0.1°C