Radio Frequency Identification Water Purification System LRFW-B11 is a 30 L capacited revolutionary, modular design which helps in elimination of large amount of salts and other minerals from water using 2 stages of RO with the least TOC level i.e. < 3 ppb. Here the concentrate or reject stream is fed into a second RO system to maximize water recovery. The unique feature of this model is that it’s equipped with a RFID Radio Frequency Identification Chip which helps keeping a check on the quality of water in real time. It’s designed to deliver compliant purified water with clear quality parameters and care free maintenance
View CatalogOutput of Pure water | ≥ 20 L / hr. |
---|---|
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Resistivity at 25 °C | 18.25 M Ω. cm |
Conductivity at 25 °C | ≤ 5 µs / cm |
TOC | < 3 ppb |
Pyrogens / Endotoxins | < 0.025 EU / ml |
Bacteria | < 1 cfu / ml |
Particles ( > 0.22 µm ) | < 1 / ml |
Absorbance ( 254 nm ) | ≤ 0.001 |
Reactive Silica ( SiO2 ) | < 0.01 ppm |
Heavy metal | < 0.01 ppm |
Electrical requirements | 220 V / 50 Hz |
Power | ≥ 200 W |
Dimensions ( L x W x H ) | 340 x 550 x 530 mm |
Weight | 45 kg |
Used in PCR / DNA preparation, HPLC, LC-MS, electrophoresis, chemical analysis experiment, protein analysis
This water purification system is a combinational system that produces Type III water after RO and Type I water after deionization in one cycle
Output of Pure water | ≥ 10 L / hr. |
Water Type | Type I and Type III |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Process | Double Pass RO system |
Output of Pure water | ≥ 20 L / hr. |
Water Type | Type I and Type III |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Process | Double Pass RO system |
Output of Pure water | ≥ 30 L / hr. |
Water Type | Type I and Type III |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Process | Double Pass RO system |
Output of Pure water | ≥ 40 L / hr. |
Water Type | Type I and Type III |
Water Tank capacity | 80 L |
Configuration | Floor Standing |
Process | Double Pass RO system |
This water purification system provides Type II level water with consistency and reliability. It removes approximately 98% of inorganic ions and 99 % of all dissolved organic substances
Output of Pure water | ≥ 10 L / hr. |
Process | Double Pass RO system |
Water Type | Type II |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Output of Pure water | ≥ 20 L / hr. |
Process | Double Pass RO system |
Water Type | Type II |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Output of Pure water | ≥ 30 L / hr. |
Process | Double Pass RO system |
Water Type | Type II |
Water Tank capacity | 30 L |
Configuration | Benchtop |
Output of Pure water | ≥ 40 L / hr. |
Process | Double Pass RO system |
Water Type | Type II |
Water Tank capacity | 80 L |
Configuration | Floor Standing |
It provides Type III level water which is required for chemical and physical inspection or for washing lab glassware’s
Output of Pure water | ≥ 10 L / hr. |
Water Type | Type III |
Configuration | Benchtop |
Process | Double Pass RO system |
Water intake flowrate | ≥ 1- 1.5 L / min |
Output of Pure water | ≥ 20 L / hr. |
Water Type | Type III |
Configuration | Benchtop |
Process | Double Pass RO system |
Water intake flowrate | ≥ 1- 1.5 L / min |
Output of Pure water | ≥ 30 L / hr. |
Water Type | Type III |
Configuration | Benchtop |
Process | Double Pass RO system |
Water intake flowrate | ≥ 1- 1.5 L / min |
Output of Pure water | ≥ 40 L / hr. |
Water Type | Type III |
Configuration | Floor Standing |
Process | Double Pass RO system |
Water intake flowrate | ≥ 1- 1.5 L / min |
Radio Frequency Identification Water Purifier are equipped with a RFID Radio Frequency Identification Chip which helps keeping a check on the quality of water in real time. This helps in monitoring of parameters for the purifier
Output of Pure water | ≥ 10 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Output of Pure water | ≥ 30 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Output of Pure water | ≥ 40 L / hr. |
Process | Double Pass RO system |
Configuration | Floor standing |
Water Tank capacity | 80 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Output of Pure water | ≥ 50 L / hr. |
Process | Double Pass RO system |
Configuration | Floor Standing |
Water Tank capacity | 80 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
UV water purification systems destroy the DNA of micro-organisms making the water contamination free. Water produced from UV water purification is contamination free water which is potable for consumption
Output of Pure water | ≥ 10 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Output of Pure water | ≥ 20 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Output of Pure water | ≥ 30 L / hr. |
Process | Double Pass RO system |
Configuration | Benchtop |
Water Tank capacity | 30 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Output of Pure water | ≥ 40 L / hr. |
Process | Double Pass RO system |
Configuration | Floor standing |
Water Tank capacity | 80 L |
Output of Ultrapure water | ≥ 1- 1.5 L / min |
Water quality | One stage (Type I) |
Feed water | RO water /Distilled water Water temperature: 5 ~ 40℃ |
Resistivity | 18.25 MΩ.cm @ 25 ℃ |
TOC | < 5ppb |
Bacteria | < 0.1 cfu/ml |
Water quality | Two stage(Type III and type I) |
Feed water | Tap waterTDS≤400ppm Water temperature: 5-40℃ Type 3 water ≥10L/h |
Conectivity |
Resistivity | 18.25 MΩ.cm @ 25 ℃ |
TOC | < 5ppb |
Output 2nd stage RO water | 90 liters/hour |
Output ultrapure water | Up to 2 liters/minute (when tank is full) |
Ultrapure Water Quality | Resistivity (25°C) 18.2 M Ω cm TOC: < 3ppb Bacteria: 0.2 µm): |
RO Water Quality | Conductivity 1st stage RO water: Feed water Conductivity ×5 % Conductivity 2nd stage RO water: 1 to 5 µs/cm |
Feed water requirements | Tap water, Temperature 5 to 45°C, Pressure 1.0 to 4.0 Kgf/cm2 |
Output 2nd stage RO water | 90 liters/hour |
Output ultrapure water | Up to 2 liters/minute (when tank is full) |
Ultrapure Water Quality | Resistivity (25°C) 18.2 M Ω cm TOC: < 3ppb Bacteria: 0.2 µm): |
EDI | Resistivity >10.2 M Ω cm TOC: < 30ppb Silicone rejection rate: >99.9 % |
RO Water Quality | Conductivity 1st stage RO water: Feed water Conductivity ×5 % Conductivity 2nd stage RO water: 1 to 5 µs/cm |
Output | 30 liters/hour |
Flow rate | Up to 2 liters/minute (with pressure tank) |
Pure water outlet | 2 reverse osmosis water, deionized water |
Deionized Water Quality | Resistivity: 16 to 18.2 M Ω cm Bacteria: N/A Particle (>0.1 µm): N/A |
RO Water Quality | Ion rejection rate: 97 % to 99% (new RO membrane) Organic rejection rate: >99 %, when MW >200 Dalton Particles and bacteria rejection rate: >99 % |
Output | 30 liters/hour |
Flow rate | Up to 2 liters/minute (with pressure tank) |
Pure water outlet | 2 reverse osmosis water, deionized water |
Deionized Water Quality | Resistivity: 16 to 18.2 M Ω cm Bacteria: N/A Particle (>0.1 µm): N/A |
RO Water Quality | Ion rejection rate: 97 % to 99% (new RO membrane) Organic rejection rate: >99 %, when MW >200 Dalton Particles and bacteria rejection rate: >99 % |