Viscometer LVM-D12 is adopted with advanced technology using micro-processor based system to control speed, test operations, data collection and interpretation. This highly sensitive Brookfield viscometer comes with 100 mPa.s to 2000000 mPa.s measurement range. Equipped with white backlight LCD display enables user to view viscosity test parameters like no. of samples, rotors specification, speed & other important information.
View CatalogMeasurement range | 100 mPa.s to 2000000 mPa.s |
---|---|
Rotors | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed | 5, 10, 20, 50 r/min |
Temperature control range | 45 to 200°C |
Temperature control accuracy | ± 0.1°C |
Sample cylinder | 20 ml |
Measurement error | ± 1% (F.S) |
Measurement mode | Manual |
Print output | Thermal printer |
Connection to PC | RS232 interface |
Power supply | AC 220V ± 10%, 50 Hz |
Relative humidity | ≤ 80% |
Ambient temperature | 5 to 35°C |
Dimension | 460 × 410 × 450 mm |
Gross weight | 14 kg |
HS Code | 90278099 |
Used to determine viscosities of asphalt, paraffin, high polymer, pharmaceutical drugs & other liquids in paint & oil industry, pharmaceuticals, food & beverage industry, high polymer and other industries.
Accessories No | Name |
1 | Water Bath |
2 | Rotor No. 30 |
3 | 300°C heating furnace |
4 | Standard viscosity oil- 200 ml |
5 | Rotor No. 21, 27, 28, 29 |
6 | Rotor No. 0 |
Measuring range | 0.3 - 50000 mm2/s |
Measure position | 2 |
Bath volume | 25 L |
Timing accuracy | 0.01 s |
Temperature range | 5 °C - 95 °C |
Measuring range | 0.3 - 50000 mm2/s |
Measure position | 4 |
Bath volume | 33 L |
Timing accuracy | 0.01 s |
Temperature range | 5 °C - 95 °C |
Measuring range | 0.3 - 50000 mm2/s |
Measure position | 6 |
Bath volume | 41 L |
Timing accuracy | 0.01 s |
Temperature range | 5 °C - 95 °C |
Measuring range | 0.35 to 5000 mm2/s |
Measure position | 2 (4 units measuring position at option) |
Bath volume | 12 L |
Timing accuracy | 0.01 s |
Temperature accuracy | Better than ± 0.01 °C |
Measurement range | 25 mPa.s to 1×10000000 mPa.s |
Rotors | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed | (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min |
Temperature control range | 45 to 200°C |
Temperature control accuracy | ± 0.1°C |
Measurement range | 100 mPa.s to 200000 mPa.s |
Rotors | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed | 5, 10, 20, 50 r/min |
Temperature control range | Room temperature to 200°C |
Temperature control accuracy | ± 0.1°C |
Viscosity Range | LV: 1 to 2000000 mPa.s |
Rotation speed range | 0.3 to 100 rpm (stepless) |
Spindles | LV: (1#, 2#, 3#, 4# spindles) (0# is optional) |
Accuracy | ± 1.0 % (of full range) |
Repeatability | 0.005 |
Viscosity Range | RV: 100 to 13000000 mPa.s |
Rotation speed range | 0.3 to 100 rpm (stepless) |
Spindles | RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
Accuracy | ± 1.0 % (of full range) |
Repeatability | 0.005 |