Semi-automatic Biochemistry Analyzer LSBA-A10 also known as chemistry analyzer is tabletop unit comes with aspiration volume ranges from 100 to 5000 µl, offers absorbance ranges from 0 to 3.0 abs. Adopts turbidimetery and colorimetry principle, equipped with different wavelengths such as 340 nm, 380 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm and 1 free position. It provides easy, quick and accurate diagnosis of blood samples.
Absorbance Range | 0 to 3.0 Abs |
---|---|
Aspiration Volume | 100 to 5000 µl |
Wavelengths | 340 nm, 380 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm and 1 free position |
Principle | Colorimetery, turbimetry |
Light Source | Halogen lamp, 6 V 10 W |
Storage | 15000 Results |
Test Method | End Point, fixed time, kinetic |
Absorbance (340 nm) Variation | ≤ 0.005 Abs |
Power Supply | AC 100 to 240 V 50/60 Hz |
Dimension | 355×330×175 mm |
Net Weight | 5.6 kg |
Semi-automatic Biochemistry Analyzer is widely used in life sciences including biotechnology, microbiology, immunology, cell and molecular biology. It is commonly used in factories, clinics and laboratories.
Absorbency Range | -0.3 to 3.0 abs |
Resolution | 0.001 abs (display), 0.0001 abs (inner calculation) |
Temperature Accuracy | ± 0.1°C |
Wavelength | 340 nm, 405 nm, 510 nm, 546 nm, 578 nm, 620 nm + 2 free positions |
Measuring System | Measuring Range: 0 to 3.0 OD<br/> Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear<br/> Photometric linearity: ±2% (0 to 3.000 OD)<br/> Photometric accuracy: ±1% (0 to 3.000 OD)<br/> Carry over: ≤1% |
Photometric System | Light source: 6 V, 10 W halogen lamp; standby function<br/> Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request)<br/> Wavelength Accuracy: ±2 nm |
Thermostatic Control | Temperature: 25˚C, 30˚C, 37˚C<br/> Precision: ±0.1˚C |
Drift | <0.005 OD/hr |
Measuring System | Measuring Range: 0 to 3.0 OD<br/> Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear<br/> Photometric linearity: ±2% (0 to 3.000 OD)<br/> Photometric accuracy: ±1% (0 to 3.000 OD)<br/> Carry over: ≤1% |
Photometric System | Light source: 6 V, 10 W halogen lamp; standby function<br/> Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request)<br/> Wavelength Accuracy: ±2 nm |
Thermostatic Control | Temperature: 25˚C, 30˚C, 37˚C<br/> Precision: ±0.1˚C |
Drift | <0.005 OD/hr |