Soil water hardness tester TSWH-A11 is a handheld design, model with large backlight LCD display and high resolution to show inverted reverse function of numbers on screen. With high accuracy measurement, it maintains the peak value display until manually zero value adjustment. It holds automatic peak function value on display screen for 2 seconds before automatic elimination.
View CatalogMaximum load | 100 kg ( kg and N can be switched automatically) |
---|---|
Resolution | 0.01 g |
Accuracy | ± 0.5 % |
Measuring depth | 0 to 450 mm |
Environmental temperature | 0 to 60°C |
Allowable overload | 1.5 |
Memory storage | Stores up to 896 groups of data |
Power supply mode | 5 Nickel Cyanogen |
Battery capacity | Continuous operated battery, 6 to 8 hrs |
Gross weight | 13 kg |
Power supply | Chargeable AC 100 to 240 voltage |
Used for soil water hardness measurement of dry to normal & moist soil for quality analysis & testing purpose.
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Accuracy | Chromaticity co-ordinate 0.0001 |
Repeatability | Rx, Ry and Rz s ≤ 0.1 chromaticity co-ordinate s ≤ 0.0010, R457 s ≤ 0.10 |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
Zero drift | ≤ 0.1 % |
Indication drift | ≤ 0.1 % |
Sample (size) length | 38×70 mm |
Measuring range | (1-500) mN.m (divided into 7 small ranges) |
Indication error | 0.02 |
Test speed | (200° ± 20°)/ min |
Dimension (L*W*H) | 220 × 230 × 350 mm |
Sample (size) length | 90 to 200 mm |
Sample width | 15 mm, 25 mm, 50mm |
Measuring range | 0 to 30, 0 to 100 N,0 to 300 N |
Accuracy | ± 1 % |
Tensile strength velocity | 1 to 399 mm/min (adjustable) |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Rotate speed of the turntable | 11 r/min to 12r/min, turntable dimension diameter: 285 mm |
Quantity of heaters | 2 pcs |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
Vacuum chamber effective size | 270 × 210 mm |
Vacuum chamber size | 300 × 350 mm |
Resolution | 0.1 % O2 |
Measuring range | 0 to 100 % O2 |
Precision | ± 0.4 % O2 |
Response time | < 10 S |
Display precision | 0.1 ± 1 % |
Temperature range | 10 to 35°C |
Maximum falling height | 2000 mm |
Resolution of displacement | 1 mm |
Height error | < ± 2 mm |
Hammer mass | 0.25 to 16 kg |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Max dimension L × W × H | 910 × 510 × 860 mm |
Effective test space of the chamber L × W × H | 280 × 170 × 120 mm |
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Display | LED display |
Heater | Cylindrical mold |
Test arm weight | 2.5 N |
Additional Loads | 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N, |
Idler | 150 mm |
Abrasion stroke | 40 ± 0.2 M |
Horizontal displacement | 4.2 mm/ rotation |
Control temperature range | Normal temperature to 200°C |
Temperature display resolution | 0.01°C |
Temperature control accuracy | ± 0.3° |
Calibration accuracy | Mooney value ± 0.5 |
Rotor speed | 2 rpm |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Hardness indication | Analogue display |
Resolution | 0.5 HR |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Hardness indication | Digital display |
Resolution | 0.1 HR |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Brinell hardness test | 306, 613, 1839 N |
Vickers hardness test | 294, 588, 980 N |
Magnification of Microscope | 37.575 x |
Test force | 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N |
Hardness value symbol | HV1, HV5, HV10, HV20, HV30, HV250 |
Error range in display | ± 3.0 %, ± 2.0 % |
Hardness indication | Digital display |
Hardness value range in Measure | 5 HV to 2500 HV |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) |
Linearity error |
Repeatability error | A (absorbency of light) |
Wavelength range | Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) |
Linearity error |
Repeatability error | A (absorbency of light) |
Wavelength range | Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm |
Salinity Measurement range | 0.00 to 19.99 ms/cm |
Measuring accuracy | EC ± 2% full scale |
Temperature Measurement range | -5 to 50°C |
Temperature accuracy | ± 0.5°C |
Temperature compensation | 0 to 50°C |
Measuring range | 0 to 100 kPa |
Resolution | 0.01 kPa |
Accuracy | ± 1 kPa |
Soil temperature measuring range | -55 to 105°C |
Temperature accuracy | ± 1°C |