Monochromator Specifications |
- Optical type: Czerny turner
- Resolution: ≤ 0.015nm (3600 line grating)<br/> ≤ 0.030nm (2400 line grating)
- Focal length: 1000 mm
- Grating specifications: huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area
- Wavelength range: 195 to 500 nm for 3600 line grating<br/> 195 to 800 nm for 2400 line grating
|
Solid State Power Specifications |
- Frequency: 27.12 MHz<br/> Frequency stability: < 0.05%
- Spray chamber: Scott double pass spray chamber
- Output power: 800 W to 1600 W, adjustable with power efficiency more than 65%
- Output power stability: ≤ 0.05%
- Induction coil: 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
|
Technical Specifications |
- Suitable sample content range: Liquid sample: 0.01 ppm to several thousand ppm<br/> Solid or power sample: 0.001% to 70%
- Repeatability: short-term stability- RSD ≤ 1.5%<br/> Long-term stability: RSD ≤ 2%
- Test speed: 5 to 8 elements / min
- Limits of detection (LOD, µg/L) for most elements: 1ppb to 10ppb
|
Control Circuit |
- Photomultiplier tube specification: R212 / R928
- Negative high voltage: -50 to -1000 V
- Circuit measuring range: (10<sup>-12</sup> to 10 <sup>-4</sup>) A
- Signal acquisition: VF conversion
|
Working Environment |
- Temperature for storage and transportation: 15°C to 25°C
- Humidity for storage and transportation: ≤ 70%
- Power Stability: 220 ± 10V; 50 to 60 V
- Humidity: ≤ 70%
- Temperature: 15°C to 30°C
|
Other Details |
- Packaging Dimension and Gross Weight (4 case): 1st case: 188 × 111 × 105 / 348 kg<br/> 2nd case: 60 × 60 × 55 / 25 kg<br/> 3rd case: 59 × 67 × 97 / 80 kg<br/> 4th case: 38.5 × 38.5 × 63 / 47 kg
|
- Highly advance optical design
- Holographic grating for minimum scattering of light
- Correction of spectral interference to improvise detection
- System controlled torch movement for optimized position
- System controlled mass flow controller for carrier gas, auxiliary gas and plasma gas
- 27.12 MHz RF generator for efficient ionization
- Auto-coupling system
- Peristaltic pump for stable flow rate and drainage of sample
- Argon gas cylinder last up to 8 hours
Auto-sampler can be provided
- Software Details
- Allows selection of multiple elements and parameters for analysis
- Faster Calibration function
- Correction of background interference
- Report generation with single button press
- Many export options
- Real-time graphical display of instrument status
- Plasma ignition with one button press
- Large database to select spectral lines according to requirement
Auto-sampler
It used for quantitative and qualitative analysis of elements in the given sample. Various fields like petrochemicals, pharmaceuticals, agriculture, environmental, food industry, metallurgy, processing industry etc. require it for several operations.