Portable Trace Drug Detector LTDD-D10 is a handheld device with a sensitivity of 0.1 pg and a temperature range of -20°C to 55°C. Features advanced Polymer Sensing Technology to identify the presence of explosive in the given sample. The existence of explosive changes the intensity of fluorescence released by fluorescent polymers which is measured by the detector. Components of the instrument includes heating sampling head, middle section of instrument and battery. LCD display, USB interface, storage space, fast response time, alarm system etc. are some of the benefits of the device. It is used in labs, security departments, military services etc.
View CatalogTemperature | -20°C to 55°C |
---|---|
TNT Detection limit | < 0.1 pg |
Alarm time | < 6 s |
Ambient temperature | -20°C to 55°C |
False alarm rate | < 1% |
Starting time |
Inhalation mode (< 10 s) wiping mode (< 2 min) |
Interface | USB |
Display | 3 inches TFT LCD |
Storage | 50,000 test results |
Rated power | 9 W |
Rated voltage | 7.4 V DC |
Adapter supply frequency | 50 Hz |
Adapter supply voltage | 100 to 220 V |
Dimensions | 365 × 108 × 63 mm |
Dimensions (Packing carton) | 465 × 390 × 235 mm |
Weight (Battery included) | 1.65 kg |
Weight (Packing box included) | ≤ 8 kg |
It is used to identify the presence of explosive in the sample. It finds application in security department, forensic labs, military departments etc.
Drug/Narcotic identification | Drug, cocaine, opiates (Heroine and morphine), cannabis (Marijuana and Hashish), methamphetamine, etc. |
Database | can add new type explosive |
Alarm | Audio and visual alert |
Sensitivity limit | 100 nanogram TNT |
Analysis time | < 8 seconds |
Drug/Narcotic identification | Cocaine hydrochloride, Heroin hydrochloride, Tetrahydrocannabinol, Methamphetamine, Ketamine hydrochloride (K powder), Morphine Hydrochloride, cannabis(Marijuana and Hashish), Add new samples if necessary |
Sampling | Dipstick tracking trace particles |
Database | can add new type explosive |
Alarm | Audio and visual alert |
Sensitivity limit | 100 Nanogram TNT |
Components Detected | Drugs: Heroin/morphine, cocaine, papaverine, etc. Drug precursors: acetone, toluene, etc. Explosives: most commercial and military explosives such as TNT, (JO) Poly, C4 (plastic explosives), TNTB, Nitrocellulose, nitroguanidine, etc. Common Drugs: cephalosporin, amoxicillin, nitronazole, ofloxacin, acaphenol powder,(headache powder) etc. |
Excitation Wavelength | 785 nm |
Laser Output Power | 0 to 500 mW |
Spectral Range | 200 cm-1 to 3100 cm-1 |
Spectral Resolution | approx. 10 cm-1 at 1000 nm |
Drug/Narcotic identification | Cocaine hydrochloride, Heroin hydrochloride, Tetrahydrocannabinol, Methamphetamine, Ketamine hydrochloride (K powder), Morphine hydrochloride; Add new samples if necessary |
Sampling | Dipstick tracking trace particles, and test strip wipe Sampling |
Database | can add new type explosive |
Alarm | Sound / light |
Sensitivity limit | 100 Nanogram TNT |