-5<\/sup>","Baseline drift ( Static ) Au \/ h":"\u2264 1.5 x 10 -4<\/sup>","Minimum detection limit":"\u2264 4 x 10 -8<\/sup>","Power":"100 W","Power supply":"90 V \/ 50 to 60 Hz","Dimension":"460 \u00d7 260 \u00d7 190 mm","Weight":"9.2 kg"}. Explore the product to find out more. Visit labtron.org!"> Analytical HPLC-A7835 Catalog | Labtron -5<\/sup>","Baseline drift ( Static ) Au \/ h":"\u2264 1.5 x 10 -4<\/sup>","Minimum detection limit":"\u2264 4 x 10 -8<\/sup>","Power":"100 W","Power supply":"90 V \/ 50 to 60 Hz","Dimension":"460 \u00d7 260 \u00d7 190 mm","Weight":"9.2 kg"}. Explore the product to find out more. Visit labtron.org!"> -5<\/sup>","Baseline drift ( Static ) Au \/ h":"\u2264 1.5 x 10 -4<\/sup>","Minimum detection limit":"\u2264 4 x 10 -8<\/sup>","Power":"100 W","Power supply":"90 V \/ 50 to 60 Hz","Dimension":"460 \u00d7 260 \u00d7 190 mm","Weight":"9.2 kg"}. Explore the product to find out more. Visit labtron.org!">

Analytical HPLC-A7835 Catalog

Overview

Analytical HPLC-A7835 system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time.

Specifications
Pump Specifications
  • Model No: HPP-B1
  • Flow rate range: 0.0001 to 10 ml / min
  • Maximum pressure: 42 MPa , 0 to 5 ml / min
  • Column size: 4.6 × 250 mm
  • Sample size: 5 μm
  • Pressure pulsation: ≤ 1.5 % at 10 MPa
  • Flow rate accuracy: ± 0.2 % at 1 ml / min
  • Flow rate repeatability %: ≤ 0.15
  • Gradient accuracy %: ± 2
  • Gradient repeatability %: ≤ 0.2
  • Dimension: 450 × 260 × 190 mm
  • Power supply: 90 V to 240 V
  • Weight: 11.2 kg
Detector Specifications
  • Model No: HPD-B2
  • Wavelength range: 190 to 800 nm
  • Wavelength accuracy: ± 0.75 nm
  • Wavelength repeatability: 0.2 nm
  • Band width: 8 nm
  • Optical path: 10 nm
  • Deuterium lamp: 190 to 400 nm
  • Tungsten lamp: 400 to 800 nm
  • Baseline noise ( Static ) Au: ≤ ± 0.5 × 10 -5
  • Baseline drift ( Static ) Au / h: ≤ 1.5 x 10 -4
  • Minimum detection limit: ≤ 4 x 10 -8
  • Power: 100 W
  • Power supply: 90 V / 50 to 60 Hz
  • Dimension: 460 × 260 × 190 mm
  • Weight: 9.2 kg

Features

  • Compression compensation ensuring gradient repeatability
  • Low pressure gradient
  • Detector ( Deuterium or tungsten lamp )
  • Simultaneous working of deuterium and tungsten lamp
  • Automatic sample injector ( Autosampler )
  • External pump control by panel or computer software
  • Auto save last detected records by the detector
  • 10 point calibration pump for linear pressure control
  • Error alarm function for over pressure ,under pressure and leakage
Optional Accessories :

Accessory Quantity
Autosampler 1
Fraction collector 1
Column oven 1

Applications :

Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis