Capacity | 260 L |
Load temperature | ≤-25ºC |
Outer rotor compressor | FM35DC |
Refrigerant | R134a |
Input voltage | 24 V |
Dispersion Type | Wet |
Measurement Range | 0.1 to 300 µm |
Channel number | 39 |
Accuracy Error | <1% (National Standard Sample D50) |
Repeatability Error | <1% (National Standard Sample D50) |
Reflect | 8º(diffused illumination, 8 degree viewing angle) |
Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
Integrating Sphere Size | Φ 40 mm |
Light Source | Combined full spectrum LED light source, UV light source |
Capacity | 340 L |
Door type | Dual door manual |
Adjustable shelf | 2 |
Shelves loading capacity | 100 kgs |
Dimension ( H x W x D ) | 1650 x 1090 x 860 mm |
Capacity | 60 L |
Number of baskets | 2 |
Sterilization temperature | 105 °C to 138 °C |
Working environment temperature | 5 °C to 45 °C |
Temperature accuracy | 0.1 °C |
Capacity | 1500 L |
Sterilization Temperature | 139 °C |
Sterilization Pressure | 0.22MPa |
Steam Pressure and the Consumption | 0.4 - 0.6 MPa / 50 kg |
Water Source Pressure and the Consumption | 0.2 to 0.3 MPa / 350 kgs |
Capacity | 20 L/hr |
Water consumption | 1:10 |
Configuration | Automated control |
Water type | Regular water |
Power |
380 V ; 4.5 kW Triple phase |
Capacity | 82/220 g |
Resolution | 0.00001 g (0.01mg) / 0.0001 g (0.1mg) |
Min weighing | 0.06 mg / 0.6 mg |
Stable Time | ≤ 6 s |
Display | LCD(green back light with black font) |
Display mode | LCD |
Heating power | 1.8 kW |
Time to boil 1 L H20 | 7 mins |
Heating zone | ᴓ 190 mm |
Maximum capacity | 25 L |
Cabinet type | Upright |
Capacity | 218 L |
Temperature range | -40 to -86˚C |
Ambient temperature | 16 to 32˚C |
Cooling performance | -86˚C |
Max. Temperature | 1200 °C |
Capacity | 5 L |
Heating Program | 8 step |
Thermal Rate | 3 °C - 20 °C |
Heating element | Fe-Cr-Al |
Control temperature range | Normal temperature to 200°C |
Temperature display resolution | 0.01°C |
Temperature control accuracy | ± 0.3° |
Calibration accuracy | Mooney value ± 0.5 |
Rotor speed | 2 rpm |
TDS range | 0 - 20 ppt |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.1 to 1.0 (default 0.5) |
Calibration points | 1 - 3 points |
TDS type range | Low range TDS |
Work Station | 1 |
Sample Volume | ≤ 250 ml |
Sample Weight | ≤ 500 g |
Number of Tapping | 0 to 99999 (set 0 to output bulk density) |
Frequency | 300 rpm (continuous adjustable in 0 to 300 rpm) |
Max. Temperature | 1250 °C |
Capacity | 7 L |
Heating Program | 8 step |
Thermal Rate | 3 °C - 20 °C |
Heating element | Fe-Cr-Al |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Repeatability | 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU) |
Reproducibility | 1.0 GU (0 to 100 GU), 1.0 % GU (100 to 1000 GU) |
Chamber Volume | 150 L |
Temperature Range | Ambient 5 °C to 60 °C |
Temperature Accuracy | ± 0.2 at 37 °C |
CO2 Range | 0 to 20 % |
CO2 Accuracy | ± 0.1 % at 37 °C |
Type | Portable; Air ionizer |
Air filter | Air purification composite filter with primary filter, activated carbon filter, photocatalyst filter |
Disinfection | Air dynamic |
Circulating Air | ≥600 m3/h |
Temperature Range | 0 to 39ºC ( Screen displays 10 to 35ºC temperature range) |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1.8 nm |
Optical system | Double beam; 1200 lines/mm grating |
Wavelength accuracy | ±0.1nm (D2 656.1nm), ±0.3nm @ all |
Wavelength repeatability | 0.2 nm |
Sterilization chamber capacity | 24 L |
Sterilization temperature range | 105 to 134°C |
Maximum working temperature | 134°C |
Maximum working pressure | 0.22 MPa |
Temperature stability | ≤±1°C |