A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type bool

Filename: helpers/common_helper.php

Line Number: 370

Backtrace:

File: /home/servetes/public_html/labtron.org/application/helpers/common_helper.php
Line: 370
Function: _error_handler

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 388
Function: generate_captcha

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 70
Function: singlecatalog

File: /home/servetes/public_html/labtron.org/index.php
Line: 318
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type bool

Filename: helpers/common_helper.php

Line Number: 374

Backtrace:

File: /home/servetes/public_html/labtron.org/application/helpers/common_helper.php
Line: 374
Function: _error_handler

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 388
Function: generate_captcha

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 70
Function: singlecatalog

File: /home/servetes/public_html/labtron.org/index.php
Line: 318
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type bool

Filename: helpers/common_helper.php

Line Number: 375

Backtrace:

File: /home/servetes/public_html/labtron.org/application/helpers/common_helper.php
Line: 375
Function: _error_handler

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 388
Function: generate_captcha

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 70
Function: singlecatalog

File: /home/servetes/public_html/labtron.org/index.php
Line: 318
Function: require_once

Online pH Controller LOPC-A10 Catalog | Labtron

Online pH Controller LOPC-A10 Catalog

Overview

Online pH Controller LOPC-A10 features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.

Specifications
pH measurement range 01.00 to 15.00 pH
pH calibration points 1 to 3 points
pH Buffer Solutions USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
mV measurement range -1000 to 1000 mV
mV accuracy ± 1 mV
mV resolution 1 mV
Temperature range 0 to 100°C , 32 to 212°F
Temperature calibration points 1 point
Temperature calibration range ± 10°C
Temperature accuracy ± 1°C
Temperature resolution 0.1°C
Signal output 4 to 20 mA
Load Max 500
Low and high alarm limits 1.00 to 10.00 pH, selectable
Connection Interface RS485
Connection Terminals Detectable screw terminals
Temperature compensation Automatic, 0 to 100°C , 32 to 212°F
Environmental conditions Ambient temperature to ≤ 60°C, RH ≤ 80%
Display LCD
Power DC 24 V
Dimension (L*W*H) 96 × 96 × 75 mm
Weight 350 g

Features

  • Equipped with industrial pH electrode
  • 1 to 3 pH calibration points with ‘Automatic buffer recognition’
  • ATC mode for accurate readings over entire range
  • Low high alarm limits set automatically activate an external device
  • Selectable temperature units °C or °F for diff. applications
  • System menu allows setting of up to 9 parameters
  • Reset features to resumes all setting back to default
  • Manual temperature calibration improves accuracy
Applications :

Used to measure pH in waste water treatment and quality inspection plants, filtration systems, RO treatment water plants, Agriculture, Aquaculture, and research industry.