-5<\/sup> AU\/h at 254 nm with methanol\/water= 80\/20","Baseline drift ( Static ) Au \/ h":"1.5 \u00d7 10-4<\/sup> AU\/h at 254 nm with methanol\/ water= 80\/20","Time constants":"16 grades adjustable","Display":"LCD backlight display","GLP":"Total number of lights, lamp replacement time and product serial number","Power":"75 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension (L \u00d7 W \u00d7 H)":"398 \u00d7 149 \u00d7 267 mm"}. Explore the product to find out more. Visit labtron.org!">
Analytical HPLC-A7840 Catalog | Labtron
-5<\/sup> AU\/h at 254 nm with methanol\/water= 80\/20","Baseline drift ( Static ) Au \/ h":"1.5 \u00d7 10-4<\/sup> AU\/h at 254 nm with methanol\/ water= 80\/20","Time constants":"16 grades adjustable","Display":"LCD backlight display","GLP":"Total number of lights, lamp replacement time and product serial number","Power":"75 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension (L \u00d7 W \u00d7 H)":"398 \u00d7 149 \u00d7 267 mm"}. Explore the product to find out more. Visit labtron.org!">
-5<\/sup> AU\/h at 254 nm with methanol\/water= 80\/20","Baseline drift ( Static ) Au \/ h":"1.5 \u00d7 10-4<\/sup> AU\/h at 254 nm with methanol\/ water= 80\/20","Time constants":"16 grades adjustable","Display":"LCD backlight display","GLP":"Total number of lights, lamp replacement time and product serial number","Power":"75 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension (L \u00d7 W \u00d7 H)":"398 \u00d7 149 \u00d7 267 mm"}. Explore the product to find out more. Visit labtron.org!">
Analytical HPLC-A7840 system with 0.001 to 9.999 ml / min flow rate range, offers three method measurement: dual wavelength detection, wavelength time program and stop pump scanning. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 700 nm to analyse sample’s absorption at different wavelengths and high-pressure pump achieves accurate solvent delivery with high-precision and low-fluctuation.
Specifications
Pump Specifications
Solvent delivery: Double plunger series mode, floating plunger design, single stroke volume 30 µl
Pump Head: 10 ml stainless steel pump head
Flow rate range: 0.001 to 9.999 ml / min
Flow rate increment: 0.001 ml/min
Maximum pressure: 42 MPa
Column size: 4.6 × 250 mm 5 µm
Pipeline Size: 1/16 inch
Flow rate accuracy: ± 0.5 %
Flow rate precision: RSD ≤ 0.1%
Gradient accuracy %: ± 0.5 %
Gradient repeatability %: RSD ≤ 0.15%
GLP: Automatic recording of pump sealing ring working time
Display: LCD backlight display
Power: 80 W
Power supply: 220 V ± 10%, 50 Hz
Dimension: 398 × 149 × 267 mm
Detector Specifications
Wavelength range: 190 to 700 nm
Wavelength accuracy: ± 1 nm
Wavelength repeatability: 0.2 nm
Deuterium lamp: 190 to 400 nm
Tungsten lamp: 400 to 700 nm
Baseline noise ( Static ) Au: 1 × 10-5 AU/h at 254 nm with methanol/water= 80/20
Baseline drift ( Static ) Au / h: 1.5 × 10-4 AU/h at 254 nm with methanol/ water= 80/20
Time constants: 16 grades adjustable
Display: LCD backlight display
GLP: Total number of lights, lamp replacement time and product serial number
Power: 75 W
Power supply: 220 V ± 10%, 50 Hz
Dimension (L × W × H): 398 × 149 × 267 mm
Features
Floating plunger support mechanism improve plunger and seal ring
Detector (Deuterium or tungsten lamp)
Simultaneous working of deuterium and tungsten lamp
Three method measurement: dual wavelength detection, wavelength time program and stop pump scanning
Independent mode all working parameter are set by panel button
External pump control by panel or computer software
Quaternary high pressure gradient support
Error alarm function for over pressure ,under pressure and leakage