A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type bool

Filename: helpers/common_helper.php

Line Number: 370

Backtrace:

File: /home/servetes/public_html/labtron.org/application/helpers/common_helper.php
Line: 370
Function: _error_handler

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 388
Function: generate_captcha

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 70
Function: singlecatalog

File: /home/servetes/public_html/labtron.org/index.php
Line: 318
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type bool

Filename: helpers/common_helper.php

Line Number: 374

Backtrace:

File: /home/servetes/public_html/labtron.org/application/helpers/common_helper.php
Line: 374
Function: _error_handler

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 388
Function: generate_captcha

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 70
Function: singlecatalog

File: /home/servetes/public_html/labtron.org/index.php
Line: 318
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type bool

Filename: helpers/common_helper.php

Line Number: 375

Backtrace:

File: /home/servetes/public_html/labtron.org/application/helpers/common_helper.php
Line: 375
Function: _error_handler

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 388
Function: generate_captcha

File: /home/servetes/public_html/labtron.org/application/controllers/Website.php
Line: 70
Function: singlecatalog

File: /home/servetes/public_html/labtron.org/index.php
Line: 318
Function: require_once

Radio Frequency Identification Water Purification System LRFW-B11 Catalog | Labtron

Radio Frequency Identification Water Purification System LRFW-B11 Catalog

Overview

Radio Frequency Identification Water Purification System LRFW-B11 is a 30 L capacited revolutionary, modular design which helps in elimination of large amount of salts and other minerals from water using 2 stages of RO with the least TOC level i.e. < 3 ppb. Here the concentrate or reject stream is fed into a second RO system to maximize water recovery. The unique feature of this model is that it’s equipped with a RFID Radio Frequency Identification Chip which helps keeping a check on the quality of water in real time. It’s designed to deliver compliant purified water with clear quality parameters and care free maintenance

Specifications
Output of Pure water ≥ 20 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Ultrapure water ≥ 1- 1.5 L / min
Resistivity at 25 °C 18.25 M Ω. cm
Conductivity at 25 °C ≤ 5 µs / cm
TOC < 3 ppb
Pyrogens / Endotoxins < 0.025 EU / ml
Bacteria < 1 cfu / ml
Particles ( > 0.22 µm ) < 1 / ml
Absorbance ( 254 nm ) ≤ 0.001
Reactive Silica ( SiO2 ) < 0.01 ppm
Heavy metal < 0.01 ppm
Electrical requirements 220 V / 50 Hz
Power ≥ 200 W
Dimensions ( L x W x H ) 340 x 550 x 530 mm
Weight 45 kg

Features

  • Radio Frequency Identification Chip integrated
  • Advanced Double Pass reverse osmosis system for excellent water quality
  • 2 levels of water purification with high recovery rate
  • Online monitoring of water resistance
  • Equipped with 30 L water holding tank
  • Least TOC level < 3ppb
  • Source of inlet water – Tap water
  • Benchtop model
  • LCD display to monitor the intake of water pressure and various parameters intuitively
  • Programmed water shortage protection alarm
  • Anti-fouling RO membrane prevention programme
  • Ease of cleansing , disinfecting and draining waste water
  • Micro filter membrane to filter out pollutants
  • Automatic RO membrane antiscale flushing to extend the life of the RO membrane
Applications :

Used in PCR / DNA preparation, HPLC, LC-MS, electrophoresis, chemical analysis experiment, protein analysis