Handheld Dust Meter LDMH-A10

Handheld Dust Meter LDMH-A10 is air quality analyzer used to monitor the concentration of particles in the air. Adopted with light scattering principle with fast detection speed. The dust meter is small, lightweight, making it handheld device. It simultaneously measure and display the results for three channels (PM 1.0, PM 2.5, and PM 10.0)

Measurement range PM 1.0, PM 2.5, and PM 10.0
Resolution 0.1 µg/m<sup>3</sup>
Concentration limits 1000 µg/m<sup>3</sup>
Accuracy 0.1
Flow rate 2.83 L/min
Channels for Count mode 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm
Sampling period 1 min to 10 min
Interface port Mini USB
Data export format Txt, excel, pdf (selectable)
Light source Laser diode > 30000 h
Display 480×320 High-resolution colour LCD display
Data storage 500,000 pcs
Power battery Li-Ion Battery
Dimension 130×45×245 mm
Weight 0.9 kg
  • Can change to count mode with 6 channel size: 0.3µm, 0.5µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm
  • LCD screen shows PM 1.0, PM 2.5, PM 10.0 at same time
  • Built-in li-ion battery for 8 hours continuous use
  • Large data storage capacity, 20 group and each group 25000 pcs data
  • Export data by USB, free software and data stored as txt, excel, PDF file as per requirement

Handheld dust Meter finds application in outdoor air quality investigations, industrial hygiene, occupational health and safety units, Quality control plants, laboratory research etc.

Particulate matter concentration PM<sub>10</sub>, PM<sub>2.5</sub>, PM<sub>1.0</sub>, TSP
Particulate channels and size 15 channels, 0.3 to 25 µm
Sensitivity 0.0001 mg/m<sup>3</sup>
Measuring Range 0.01 to 20 mg/m<sup>3</sup>
Particle size channels 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm<hr> 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
Flow rates 2.83 L/min<hr> 50 mL/min
Sensitivity 0.3 µm
Test class Class 100 ∼ Class 300,000
Particle size channels 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
Flow rate 0.1 CFM ( 2.83 L/min )
Test class Class 100 ∼ Class 300,000
Test period 1 min ∼ 15 min ( 15 levels )
Particle size channels 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Flow Rate 50 L/min
Sensitivity 0.3 µm
Test period 1 sec ∼ 3599 sec ( 5 L ∼ 3000 L )
Particle size channels 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Flow Rate 1.0 CFM ( 28.3 L/min )
Sensitivity 0.3 µm
Test period 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )
Size channel 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 (µm)
Flow rate 28.3 L/min
Teat way UCL
Test period 1 to 40 minute
Measurement range PM 1.0, PM 2.5, and PM 10.0
Resolution 0.1 µg/m<sup>3</sup>
Concentration limits 1000 µg/m<sup>3</sup>
Accuracy 0.1
Particulate matter concentration PM<sub>10</sub>, PM<sub>2.5</sub>, PM<sub>1.0</sub>, TSP
Particulate channels and size 15 channels, 0.3 to 25 µm
Sensitivity 0.0001 mg/m<sup>3</sup>
Measuring Range 0.01 to 20 mg/m<sup>3</sup>