Benchtop Conductivity Meter LBCM-A14 Catalog

Overview

Benchtop Conductivity Meter LBCM-A14 with 1 to 3 points push button conductivity calibration, automatically recognizes calibration standards. With setup menu, it does setting of 6 parameters calibration points, temperature units and others. Large LCD display shows settings and measurement values. Temperature calibration by manual method improves the accuracy of conductivity meter.

Specifications
Conductivity Mode
  • Conductivity measurement range: 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
  • Conductivity accuracy: ±1% F.S.
  • Conductivity resolution: 0.001, 0.01, 0.1, 1
  • Conductivity calibration points: 1 to 3 points
  • Conductivity calibration solutions: 10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
TDS Mode
  • TDS measurement Range: 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
  • TDS Accuracy: ± 1 % F.S.
  • TDS Factor: 0.01 to 1.00 (default 0.5)
  • TDS Calibration points: 3 points
Temperature Mode
  • Temperature range: 0 to 105°C, 32 to 221°F
  • Temperature accuracy: ±1°C
  • Temperature resolution: 0.1°C, 0.1°F
  • Temperature calibration points: 1 point
  • Temperature Compensation Range and Mode: Manual or Automatic, 0 to 100°C , 32 to 212°F
  • Temperature coefficient: 0.0 to 10.0 % per °C
Cell constant K=0.1, 1, 10
Power requirements DC 9 V, using AC adapter, AC 220 V, 50 Hz
Dimension (L×W×H) 210 × 205 × 75 mm
Weight 1.5 kg

Features

  • Measures conductivity, TDS, Temperature of the liquids
  • Automatic temperature compensation for accurate values over the entire range
  • Selectable temperature units (°C or °F) for different application requirements
  • Reset function automatically resumes all the setting back to factory default options
  • Manual and automatic mode of temperature calibration
  • Auto hold feature to lock, record and read stable measurement endpoint
  • Stability indicator displays the status of current measurement
  • Help message as an operational guide, with quick access to test parameters
  • <b>Conductivity/TDS Mode</b>
  • 1 to 3 Conductivity push button calibration points
  • 3 TDS calibration points
  • 1 Temperature calibration point
Optional Accessories :

Accessories no. Name
1 Conductivity Electrode (K=0.1) suitable for measuring the low conductivity liquids ( <10µS/ cm) e.g. Pure water
2 Conductivity Electrode (K=10) suitable for measuring the high conductivity liquids (>20mS/ cm) e.g. Sea water

Applications :

Used to test Conductivity, TDS values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose