Ion Chromatography

Ion chromatograph system LICS-A20
Ion chromatograph system LICS-A20
Ion Chromatographic Pump
Type High pressure and low pulse double plunger tandem advection pump
Maximum pressure 35 MPa (PEEK)
Pressure display accuracy ≤ 0.1 MPa
Flow stability (0.2 to 0.5) ml/ min ≤ 3 %
(0.5 to 1.0) ml/ min ≤ 2 %
> 1.0 ml/ min 2 %
Flow range 0.001 to 9.999 ml/ min
Pressure pulse ≤ 0.5%
Conductivity detector
Type Temperature Control and Bipolar Conductivity Detector
Detection mode Bipolar conductivity detection
Cell volume ≤ 0.8 µL
Detection range 0 to 35000 µS/ cm
Detection resolution ≤ 0.0020 nS/ cm
Output voltage - 6000 to +6000 mV (adjustable)
Baseline noise ≤ 0.05 % F.S.
Baseline drift ≤ 3 % FS/ 30 min
Operating temperature range Room temperature +5 to 60°C (41 to 140°F)
Controlling temperature accuracy ± 0.01°C
Maximum pressure 10 MPa
Linear range ≥ 103
Instruments linearity ≥ 0.999
Quantitative repeatability ≤ 1.0 %
Qualitative repeatability ≤ 1.0 %
Minimum detectable concentration Cl ≤ 0.0005 ug/ ml
BrO3 ≤ 0.001 ug/ ml
Li+ ≤ 0.001 ug/ ml
Flow system
Plastic flow path Made of PEEK materials
Six way Valve PEEK material, 5000 psi pressure, independent automatic collection and flow function
Degassing Device
Inner volume 300 µl
Degassing volume 7.5 ml
Maximum flow rate 10 ml/ min
Degassing efficiency Degassing 90 % at 1ml/ min
Organic tolerance 1
Built-in Eluent Generator
Eluent types KOH/ NaOH
Eluent concentration range 0.1 to 100 mM
Concentration increment 0.1 mM
Flow rate change 0.1 to 3.0 ml/ min
Maximum pressure 20 MPa
Minimum pressure 5 MPa
Ion chromatograph system LICS-A21
Ion chromatograph system LICS-A21
Ion Chromatographic Pump
Type High pressure and low pulse double plunger tandem advection pump
Maximum pressure 35 MPa (PEEK)
Pressure display accuracy ≤ 0.1 MPa
Flow stability (0.2 to 0.5) ml/ min ≤ 3 %
(0.5 to 1.0) ml/ min ≤ 2 %
> 1.0 ml/ min 2 %
Flow range 0.001 to 9.999 ml/ min
Pressure pulse ≤ 0.5%
Conductivity detector
Type Temperature Control and Bipolar Conductivity Detector
Detection mode Bipolar conductivity detection
Cell volume ≤ 0.8 µL
Detection range 0 to 45000 µS/ cm
Detection resolution ≤ 0.0020 nS/ cm
Output voltage - 6000 to +6000 mV (adjustable)
Baseline noise ≤ 0.05 % F.S.
Baseline drift ≤ 3 % FS/ 30 min
Operating temperature range Room temperature +5 to 60°C (41 to 140°F)
Controlling temperature accuracy ± 0.01°C
Maximum pressure 10 MPa
Linear range ≥ 103
Instruments linearity ≥ 0.999
Quantitative repeatability ≤ 1.0 %
Qualitative repeatability ≤ 1.0 %
Minimum detectable concentration Cl ≤ 0.0005 ug/ ml
BrO3 ≤ 0.001 ug/ ml
Li+ ≤ 0.001 ug/ ml
Flow system
Plastic flow path Made of PEEK materials
Six way Valve PEEK material, 5000 psi pressure, independent automatic collection and flow function
Power supply 150 W
External dimension 350 × 470 × 510 mm
Ion chromatograph system LICS-A22
Ion chromatograph system LICS-A22
Ion Chromatographic pump
Type High pressure and low pulse double plunger tandem advection pump
Maximum pressure 35 MPa (PEEK)
Display pressure accuracy ≤ 0.1 MPa
Flow stability (0.2 to 0.5) ml/ min ≤ 3 % , (0.5 to 1.0) ml/ min ≤ 2 %, > 1.0 ml/ min ≤ 2 %
Flow range 0.001 to 9.999 ml/ min
Pressure pulse ≤ 0.5 %
Numerical control and electromagnetic injection
Maximum pressure 35 MPa
Contact material of the rotor PEEK
Control mode By Stepper motor
Power supply DC 24 V
Column heater
Operating temperature range Room temperature 20 to 60°C ( 68 to 140°F)
Controlling temperature accuracy ± 0.01°C
Allowable deviation of column heater temperature ± 2°C
Temperature stability ≤ 1°C/ h
Flow system
Plastic flow path Made up of PEEK material
Six way valve PEEK material pressure 5000 psi, independent automatic collection and flow function
Thermal buffer system for Eluent
Temperature range 25 to 40°C ( 77 to 104°F)