Ambient temperature | ≤ 30 ℃ |
Refrigeration speed | > 40 °C / 10 min |
Repeatability for solidifying point | ≤ 2 °C |
Repeatability for pour point | ≤ 3 °C |
Reproducibility | ± 4 °C |
Ambient temperature | (-10)℃ ~ 35 ℃ |
Relative humidity | ≤ 85 % |
Sample cup Inner diameter | 31.0 ~ 32.0 mm |
Sample cup Wall thickness | 1.0 ~ 1.5 mm |
Sample cup Height | 115 ~ 125 mm |
Freezing point range | -54°C to 2°C |
Cold bath measurement temperature range | -70° to 20°C |
Temperature controlling accuracy | ±0.5°C |
Bath liquids stirring | Electric |
Bath liquids stirring range | 1200 r/min |
Refrigeration system | New-type refrigeration compressor |
Controlling temperature of cold trough | Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Dimensions | 930 x 570 x 108 mm |
Chamber quantity | 2 chambers |
Chamber 01 temperature control | Ambient to -51 ℃ |
Chamber 02 temperature control | Ambient to -65 ℃ |
Temperature precision | ±1°C |
Ambient temperature | ≤ 30°C |
Refrigeration system | New-type refrigeration compressor |
Controlling temperature of cold trough | Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Inner Dimensions | 560 x 380 x 250 mm |
Capacity | 20 L |
Temperature range | Ambient +5°C to 100°C |
Precision | ± 0.1℃ |
Stirring range | 1200 r/min |
Heating | Two grades |
Temperature controlling accuracy | ± 0.5 °C |
Refrigeration system | New-type refrigeration compressor |
Cold trough | One trough with two baths, temperatures in two baths are equal |
Controlling temperature of cold trough | Room temperature ~ (-70) °C |
Temperature Range | 20 °C ~ 80 °C |
Refrigeration system | New-type refrigeration compressor |
Cold trough | One trough with two baths, temperatures in two baths are equal |
Controlling temperature of cold trough | Room temperature ~ (-70) °C |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Temperature controlling accuracy | ± 0.5 ℃ |
Refrigeration system | New-type refrigeration compressor |
Cold trough | Two holes in one trough, and same temperature |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Temperature controlling accuracy | ± 0.5 °C |
Refrigeration system | New-type refrigeration compressor |
Cold trough | One trough with two baths, temperatures in two baths are equal |
Controlling temperature of cold trough | Room temperature ~ (-70) °C |
Ambient temperature | ≤ 30 ℃ |