Low Temperature Tester

Automatic Pour Point Tester LLTT-A23
Automatic Pour Point Tester LLTT-A23
Ambient temperature ≤ 30 ℃
Refrigeration speed > 40 °C / 10 min
Repeatability for solidifying point ≤ 2 °C
Repeatability for pour point ≤ 3 °C
Reproducibility ± 4 °C
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Sample cup Height 115 ~ 125 mm
Freezing Point Tester LLTT-A11
Freezing Point Tester LLTT-A11
Freezing point range -54°C to 2°C
Cold bath measurement temperature range -70° to 20°C
Temperature controlling accuracy ±0.5°C
Bath liquids stirring Electric
Bath liquids stirring range 1200 r/min
Multifunctional Low Temperature Tester LLTT-A16
Multifunctional Low Temperature Tester LLTT-A16
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Dimensions 930 x 570 x 108 mm
Pour and Cloud Point Tester LLTT-A14
Pour and Cloud Point Tester LLTT-A14
Chamber quantity 2 chambers
Chamber 01 temperature control Ambient to -51 ℃
Chamber 02 temperature control Ambient to -65 ℃
Temperature precision ±1°C
Ambient temperature ≤ 30°C
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Inner Dimensions 560 x 380 x 250 mm
Solidifying Point Constant Temperature Water Bath LLTT-A10
Solidifying Point Constant Temperature Water Bath LLTT-A10
Capacity 20 L
Temperature range Ambient +5°C to 100°C
Precision ± 0.1℃
Stirring range 1200 r/min
Heating Two grades
Solidifying Point Tester ('-20°C +80°C') LLTT-A22
Solidifying Point Tester ('-20°C +80°C') LLTT-A22
Temperature controlling accuracy ± 0.5 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Temperature Range 20 °C ~ 80 °C
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Solidifying Point Tester LLTT-A13
Solidifying Point Tester LLTT-A13
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Solidifying Point Tester LLTT-A20
Solidifying Point Tester LLTT-A20
Temperature controlling accuracy ± 0.5 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Ambient temperature ≤ 30 ℃