Micropipettes

We offer a comprehensive collection of micropipettes with levels of accuracy and precision designed for better and quick one handed operation, these are used to dispense measured volume of liquids with a rapid release valve for quick and easy dispensing. These are autoclavable and light to use with disposable pipette tips.

Fixed Volume Fully Autoclavable Pipettes FVP100L
Fixed Volume Fully Autoclavable Pipettes FVP100L
Test Volume 5 μL
Accuracy error 1.3 %
Precision error 1.2 %
Fixed Volume Fully Autoclavable Pipettes FVP101L
Fixed Volume Fully Autoclavable Pipettes FVP101L
Test Volume 10 μL
Accuracy error 0.8 %
Precision error 0.8 %
Fixed Volume Fully Autoclavable Pipettes FVP102L
Fixed Volume Fully Autoclavable Pipettes FVP102L
Test Volume 20 μL
Accuracy error 0.6 %
Precision error 0.5 %
Fixed Volume Fully Autoclavable Pipettes FVP103L
Fixed Volume Fully Autoclavable Pipettes FVP103L
Test Volume 25 μL
Accuracy error 0.5 %
Precision error 0.3 %
Fixed Volume Fully Autoclavable Pipettes FVP104L
Fixed Volume Fully Autoclavable Pipettes FVP104L
Test Volume 50 μL
Accuracy error 0.5 %
Precision error 0.3 %
Fixed Volume Fully Autoclavable Pipettes FVP105L
Fixed Volume Fully Autoclavable Pipettes FVP105L
Test Volume 100 μL
Accuracy error 0.5 %
Precision error 0.3 %
Fixed Volume Fully Autoclavable Pipettes FVP106L
Fixed Volume Fully Autoclavable Pipettes FVP106L
Test Volume 200 μL
Accuracy error 0.4 %
Precision error 0.2 %
Fixed Volume Fully Autoclavable Pipettes FVP107L
Fixed Volume Fully Autoclavable Pipettes FVP107L
Test Volume 250 μL
Accuracy error 0.4 %
Precision error 0.2 %
Fixed Volume Fully Autoclavable Pipettes FVP108L
Fixed Volume Fully Autoclavable Pipettes FVP108L
Test Volume 500 μL
Accuracy error 0.3 %
Precision error 0.2 %
Fixed Volume Fully Autoclavable Pipettes FVP109L
Fixed Volume Fully Autoclavable Pipettes FVP109L
Test Volume 1000 μL
Accuracy error 0.3 %
Precision error 0.2 %
Fixed Volume Fully Autoclavable Pipettes FVP110L
Fixed Volume Fully Autoclavable Pipettes FVP110L
Test Volume 2000 μL
Accuracy error 0.3 %
Precision error 0.15 %
Fixed Volume Fully Autoclavable Pipettes FVP111L
Fixed Volume Fully Autoclavable Pipettes FVP111L
Test Volume 5000 μL
Accuracy error 0.3 %
Precision error 0.15 %
Fixed Volume Pipettes FVP200L
Fixed Volume Pipettes FVP200L
Test Volume 5 μL
Accuracy error 1.3 %
Precision error 1.2 %
Fixed Volume Pipettes FVP201L
Fixed Volume Pipettes FVP201L
Test Volume 10 μL
Accuracy error 0.8 %
Precision error 0.8 %
Fixed Volume Pipettes FVP202L
Fixed Volume Pipettes FVP202L
Test Volume 20 μL
Accuracy error 0.6 %
Precision error 0.5 %
Fixed Volume Pipettes FVP203L
Fixed Volume Pipettes FVP203L
Test Volume 25 μL
Accuracy error 0.5 %
Precision error 0.3 %
Fixed Volume Pipettes FVP204L
Fixed Volume Pipettes FVP204L
Test Volume 50 μL
Accuracy error 0.5 %
Precision error 0.3 %
Fixed Volume Pipettes FVP205L
Fixed Volume Pipettes FVP205L
Test Volume 100 μL
Accuracy error 0.5 %
Precision error 0.3 %
Fixed Volume Pipettes FVP206L
Fixed Volume Pipettes FVP206L
Test Volume 200 μL
Accuracy error 0.4 %
Precision error 0.2 %
Fixed Volume Pipettes FVP207L
Fixed Volume Pipettes FVP207L
Test Volume 250 μL
Accuracy error 0.4 %
Precision error 0.2 %
Fixed Volume Pipettes FVP208L
Fixed Volume Pipettes FVP208L
Test Volume 500 μL
Accuracy error 0.3 %
Precision error 0.2 %
Fixed Volume Pipettes FVP209L
Fixed Volume Pipettes FVP209L
Test Volume 1000 μL
Accuracy error 0.3 %
Precision error 0.2 %
Fixed Volume Pipettes FVP210L
Fixed Volume Pipettes FVP210L
Test Volume 2000 μL
Accuracy error 0.3 %
Precision error 0.15 %
Fixed Volume Pipettes FVP211L
Fixed Volume Pipettes FVP211L
Test Volume 5000 μL
Accuracy error 0.3 %
Precision error 0.15 %
Single Channel Electronic pipette SEP100L
Single Channel Electronic pipette SEP100L
Volume Range 0.5 – 10 μL
Increment 0.01 μL
Test Volume 10 μL
1 μL
Accuracy Error ±1.00 %
±3.50 %
Precision Error 0.50 %
3.00 %
Single Channel Electronic pipette SEP101L
Single Channel Electronic pipette SEP101L
Volume Range 5 – 50 μL
Increment 0.1 μL
Test Volume 50 μL
5 μL
Accuracy Error ±0.80 %
±3.00 %
Precision Error 0.3 %
2.50 %
Single Channel Electronic pipette SEP102L
Single Channel Electronic pipette SEP102L
Volume Range 30 – 300 μL
Increment 1 μL
Test Volume 300 μL
30 μL
Accuracy Error ±0.60 %
±3.00 %
Precision Error 0.20 %
0.70 %
Single Channel Electronic pipette SEP103L
Single Channel Electronic pipette SEP103L
Volume Range 100 - 1000 μL
Increment 5 μL
Test Volume 1000 μL
100 μL
Accuracy Error ±0.60 %
±3.00 %
Precision Error 0.20 %
0.60 %
Variable Volume Fully Autoclavable Pipettes VVP100L
Variable Volume Fully Autoclavable Pipettes VVP100L
Volume Range 0.1 - 2.5 μL
Increment 0.05 μL
Test Volume 2.5 μL
1.25 μL
0.25 μL
Accuracy error 2.50 %
3.00 %
12.00 %
Precision error 2.00 %
3.00 %
6.00 %
Variable Volume Fully Autoclavable Pipettes VVP101L
Variable Volume Fully Autoclavable Pipettes VVP101L
Volume Range 0.5 - 10 μL
Increment 0.1 μL
Test Volume 10 μL
5 μL
1 μL
Accuracy error 1.00 %
1.50 %
2.50 %
Precision error 0.80 %
1.50 %
1.50 %
Variable Volume Fully Autoclavable Pipettes VVP102L
Variable Volume Fully Autoclavable Pipettes VVP102L
Volume Range 2 - 20 μL
Increment 0.5 μL
Test Volume 20 μL
10 μL
2 μL
Accuracy error 0.90 %
1.20 %
3.00 %
Precision error 0.40 %
1.00 %
2.00 %
Variable Volume Fully Autoclavable Pipettes VVP103L
Variable Volume Fully Autoclavable Pipettes VVP103L
Volume Range 5 - 50 μL
Increment 0.5 μL
Test Volume 50 μL
25 μL
5 μL
Accuracy error 0.60 %
0.90 %
2.00 %
Precision error 0.30 %
0.60 %
2.00 %
Variable Volume Fully Autoclavable Pipettes VVP104L
Variable Volume Fully Autoclavable Pipettes VVP104L
Volume Range 10 - 100 μL
Increment 1 μL
Test Volume 100 μL
50 μL
10 μL
Accuracy error 0.80 %
1.00 %
3.00 %
Precision error 0.15 %
0.40 %
1.50 %
Variable Volume Fully Autoclavable Pipettes VVP105L
Variable Volume Fully Autoclavable Pipettes VVP105L
Volume Range 20 - 200 μL
Increment 1 μL
Test Volume 200 μL
100 μL
20 μL
Accuracy error 0.60 %
0.80 %
3.00 %
Precision error 0.15 %
0.30 %
1.0 %
Variable Volume Fully Autoclavable Pipettes VVP106L
Variable Volume Fully Autoclavable Pipettes VVP106L
Volume Range 50 - 200μL
Increment 1 μL
Test Volume 200 μL
100 μL
50 μL
Accuracy error 0.60 %
0.80 %
1.00 %
Precision error 0.15 %
0.30 %
0.40 %
Variable Volume Fully Autoclavable Pipettes VVP107L
Variable Volume Fully Autoclavable Pipettes VVP107L
Volume Range 100 - 1000μL
Increment 5 μL
Test Volume 1000 μL
500 μL
100 μL
Accuracy error 0.60 %
0.70 %
2.00 %
Precision error 0.20 %
0.25 %
0.70 %
Variable Volume Fully Autoclavable Pipettes VVP108L
Variable Volume Fully Autoclavable Pipettes VVP108L
Volume Range 200 - 1000μL
Increment 5 μL
Test Volume 1000 μL
500 μL
200 μL
Accuracy error 0.60 %
0.70 %
0.90 %
Precision error 0.20 %
0.25 %
0.30 %
Variable Volume Fully Autoclavable Pipettes VVP109L
Variable Volume Fully Autoclavable Pipettes VVP109L
Volume Range 1000 - 5000 μL
Increment 50 μL
Test Volume 5000 μL
2500 μL
1000 μL
Accuracy error 0.50 %
0.60 %
0.70 %
Precision error 0.15 %
0.30 %
0.30 %
Variable Volume Multi Channel Fully Autoclavable Pipette VMP100L
Variable Volume Multi Channel Fully Autoclavable Pipette VMP100L
No of Channels 8
Volume Range 0.5 -10 μL
Increment 0.1 μL
Test Volume 10 μL
5 μL
1 μL
Accuracy error 1.50 %
2.50 %
4.00 %
Variable Volume Multi Channel Fully Autoclavable Pipette VMP101L
Variable Volume Multi Channel Fully Autoclavable Pipette VMP101L
No of Channels 8
Volume Range 5-50 μL
Increment 0.5 μL
Test Volume 50 μL
25 μL
5 μL
Accuracy error 1.00 %
1.50 %
3.00 %
Variable Volume Multi Channel Fully Autoclavable Pipette VMP102L
Variable Volume Multi Channel Fully Autoclavable Pipette VMP102L
No of Channels 8
Volume Range 50-300 μL
Increment 5 μL
Test Volume 300 μL
150 μL
50 μL
Accuracy error 0.70 %
1.00 %
1.50 %
Variable Volume Multi Channel Fully Autoclavable Pipette VMP103L
Variable Volume Multi Channel Fully Autoclavable Pipette VMP103L
No of Channels 12
Volume Range 0.5-10 μL
Increment 0.1 μL
Test Volume 10 μL
5 μL
1 μL
Accuracy error 1.50 %
2.50 %
4.00 %
Variable Volume Multi Channel Fully Autoclavable Pipette VMP104L
Variable Volume Multi Channel Fully Autoclavable Pipette VMP104L
No of Channels 12
Volume Range 5-50 μL
Increment 0.5 μL
Test Volume 50 μL
25 μL
5 μL
Accuracy error 1.00 %
1.50 %
3.00 %
Variable Volume Multi Channel Fully Autoclavable Pipette VMP105L
Variable Volume Multi Channel Fully Autoclavable Pipette VMP105L
No of Channels 12
Volume Range 50-300 μL
Increment 5 μL
Test Volume 300 μL
150 μL
50 μL
Accuracy error 0.70 %
1.00 %
1.50 %
Variable Volume Multi Channel Pipette VMP200L
Variable Volume Multi Channel Pipette VMP200L
No of Channels 8
Volume Range 0.5 -10 μL
Increment 0.1 μL
Test Volume 10 μL
5 μL
1 μL
Accuracy error 1.50 %
2.50 %
4.00 %
Variable Volume Multi Channel Pipette VMP201L
Variable Volume Multi Channel Pipette VMP201L
No of Channels 8
Volume Range 5-50 μL
Increment 0.5 μL
Test Volume 50 μL
25 μL
5 μL
Accuracy error 1.00 %
1.50 %
3.00 %
Variable Volume Multi Channel Pipette VMP202L
Variable Volume Multi Channel Pipette VMP202L
No of Channels 8
Volume Range 50-300 μL
Increment 5 μL
Test Volume 300 μL
150 μL
50 μL
Accuracy error 0.70 %
1.00 %
1.50 %
Variable Volume Multi Channel Pipette VMP203L
Variable Volume Multi Channel Pipette VMP203L
No of Channels 12
Volume Range 0.5-10 μL
Increment 0.1 μL
Test Volume 10 μL
5 μL
1 μL
Accuracy error 1.50 %
2.50 %
4.00 %
Variable Volume Multi Channel Pipette VMP204L
Variable Volume Multi Channel Pipette VMP204L
No of Channels 12
Volume Range 5-50 μL
Increment 0.5 μL
Test Volume 50 μL
25 μL
5 μL
Accuracy error 1.00 %
1.50 %
3.00 %
Variable Volume Multi Channel Pipette VMP205L
Variable Volume Multi Channel Pipette VMP205L
No of Channels 12
Volume Range 50-300 μL
Increment 5 μL
Test Volume 300 μL
150 μL
50 μL
Accuracy error 0.70 %
1.00 %
1.50 %
Variable Volume Pipette VVP200L
Variable Volume Pipette VVP200L
Volume Range 0.1 - 2.5 μL
Increment 0.05 μL
Test Volume 2.5 μL
1.25 μL
0.25 μL
Accuracy error 2.50 %
3.00 %
12.00 %
Precision error 2.00 %
3.00 %
6.00 %
Variable Volume Pipette VVP201L
Variable Volume Pipette VVP201L
Volume Range 0.5 - 10 μL
Increment 0.1 μL
Test Volume 10 μL
5 μL
1 μL
Accuracy error 1.00 %
1.50 %
2.50 %
Precision error 0.80 %
1.50 %
1.50 %
Variable Volume Pipette VVP202L
Variable Volume Pipette VVP202L
Volume Range 2 - 20 μL
Increment 0.5 μL
Test Volume 20 μL
10 μL
2 μL
Accuracy error 0.90 %
1.20 %
3.00 %
Precision error 0.40 %
1.00 %
2.00 %
Variable Volume Pipette VVP203L
Variable Volume Pipette VVP203L
Volume Range 5 - 50 μL
Increment 0.5 μL
Test Volume 50 μL
25 μL
5 μL
Accuracy error 0.60 %
0.90 %
2.00 %
Precision error 0.30 %
0.60 %
2.00 %
Variable Volume Pipette VVP204L
Variable Volume Pipette VVP204L
Volume Range 10 - 100 μL
Increment 1 μL
Test Volume 100 μL
50 μL
10 μL
Accuracy error 0.80 %
1.00 %
3.00 %
Precision error 0.15 %
0.40 %
1.50 %
Variable Volume Pipette VVP205L
Variable Volume Pipette VVP205L
Volume Range 20 - 200 μL
Increment 1 μL
Test Volume 200 μL
100 μL
20 μL
Accuracy error 0.60 %
0.80 %
3.00 %
Precision error 0.15 %
0.30 %
1.0 %
Variable Volume Pipette VVP206L
Variable Volume Pipette VVP206L
Volume Range 50 - 200μL
Increment 1 μL
Test Volume 200 μL
100 μL
50 μL
Accuracy error 0.60 %
0.80 %
1.00 %
Precision error 0.15 %
0.30 %
0.40 %
Variable Volume Pipette VVP207L
Variable Volume Pipette VVP207L
Volume Range 100 - 1000μL
Increment 5 μL
Test Volume 1000 μL
500 μL
100 μL
Accuracy error 0.60 %
0.70 %
2.00 %
Precision error 0.20 %
0.25 %
0.70 %
Variable Volume Pipette VVP208L
Variable Volume Pipette VVP208L
Volume Range 200 - 1000μL
Increment 5 μL
Test Volume 1000 μL
500 μL
200 μL
Accuracy error 0.60 %
0.70 %
0.90 %
Precision error 0.20 %
0.25 %
0.30 %
Variable Volume Pipette VVP209L
Variable Volume Pipette VVP209L
Volume Range 1000 - 5000 μL
Increment 50 μL
Test Volume 5000 μL
2500 μL
1000 μL
Accuracy error 0.50 %
0.60 %
0.70 %
Precision error 0.15 %
0.30 %
0.30 %
Variable Volume Pipette VVP210L
Variable Volume Pipette VVP210L
Volume Range 2 - 10 mL
Increment 0.1 mL
Test Volume 10 mL
5 mL
2 mL
Accuracy error 0.60 %
1.20 %
3.00 %
Precision error 0.20 %
0.30 %
0.60 %