Plastic Testing Instruments

Aging Oven TAO-A10
Aging Oven TAO-A10
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Quantity of heaters 2 pcs
Charpy/ Izod Impact Tester TCI-A10
Charpy/ Izod Impact Tester TCI-A10
Impact Speed & Energy (charpy) 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
Impact energy (Izod) 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
Resolution of impact energy 0.001 J
Pendulum up angle 160°
Impact center distance (Charpy) 221 mm for 1J, 2J, 4J, 5J & 380 mm 7.5J, 15J, 25J
Falling Weight Impact Tester TFWT-A10
Falling Weight Impact Tester TFWT-A10
Temperature range 10 to 35°C
Maximum falling height 2000 mm
Resolution of displacement 1 mm
Height error < ± 2 mm
Hammer mass 0.25 to 16 kg
Heat sealer THS-A10
Heat sealer THS-A10
Seal temperature Room temperature -250°C
Control accuracy ± 0.2°C
Dwell time 0.1 S to 999.9 S
Dwell pressure 0.05 to 0.7 MPa
Heating mode Single and double heating surface
Lasting adhesive tester TLAT-A10
Lasting adhesive tester TLAT-A10
Standard roller 2000 ± 50 g
Testing stations 3
Dimension (L*W*H) tester 320×210×550 mm (3 stations)
Weight for stations 10 kg (3 stations)
Weight of the plates 1000 ± 3 g ( with triangle hook)
Lasting adhesive tester TLAT-A11
Lasting adhesive tester TLAT-A11
Standard roller 2000 ± 50 g
Testing stations 6
Dimension (L*W*H) tester 650×210×550 mm (6 stations)
Weight for stations 15 kg (6 stations)
Weight of the plates 1000 ± 3 g ( with triangle hook)
Melt flow Indexer TMFI-A10
Melt flow Indexer TMFI-A10
Measuring range 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
Measuring rate 0.001 S
Temperature range 50 to 400°C
Temperature precision ± 0.5°C
Resolution 0.1°C
Melt flow Indexer TMFI-A11
Melt flow Indexer TMFI-A11
Measuring range 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
Measuring rate 0.001 S
Temperature range 50 to 400°C
Temperature precision ± 0.5°C
Resolution 0.1°C
Oxygen Index Tester TOIT-A10
Oxygen Index Tester TOIT-A10
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
Display precision 0.1 ± 1 %
Primary adhesive tester TPAT-A10
Primary adhesive tester TPAT-A10
Inclined adjustable angle 0 to 40°
Panel width 120 mm
Test area width 80 mm
Standard steel balls 1/32 to 1 inch
Dimension (L*W*H) 320×140×180 mm
Vacuum Leak Tester TVLT-A10
Vacuum Leak Tester TVLT-A10
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm
Vacuum chamber size 300 × 350 mm
Vicat softening temperature & HDT machine TVHT-A10
Vicat softening temperature & HDT machine TVHT-A10
Operating temperature Ambient temperature to 300°C
Heating rate 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
Maximum temp. error with heating speed ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Range of deformation 0 to 10 mm
Deformation measurement method Digi gauge