Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV-Vis Spectrophotometer LUS-C10
Single Beam UV-Vis Spectrophotometer LUS-C10
Wavelength Range 200 to 1000 nm
Spectral Bandwidth 4.0 nm
Optical System Single beam
Wavelength Accuracy ±0.2 nm
Wavelength Repeatability 0.2 nm
Single Beam UV/Vis Spectrophotometer LUS-A50
Single Beam UV/Vis Spectrophotometer LUS-A50
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Single beam 1200 lines/mm
Single Beam UV/Vis Spectrophotometer LUS-A51
Single Beam UV/Vis Spectrophotometer LUS-A51
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Single beam 1200 lines/mm
Single Beam UV/Vis Spectrophotometer LUS-A52
Single Beam UV/Vis Spectrophotometer LUS-A52
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Single beam 1200 lines/mm
Single Beam UV/Visible Spectrophotometer LUS-A10
Single Beam UV/Visible Spectrophotometer LUS-A10
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Photometric Range 0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C
Single Beam UV/Visible Spectrophotometer LUS-A11
Single Beam UV/Visible Spectrophotometer LUS-A11
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 1.8 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Photometric Range 0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C
Single Beam UV/Visible Spectrophotometer LUS-A20
Single Beam UV/Visible Spectrophotometer LUS-A20
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Repeatability ≤ 0.2 nm
Single Beam UV/Visible Spectrophotometer LUS-A21
Single Beam UV/Visible Spectrophotometer LUS-A21
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 1.8 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.1 nm
Single Beam UV/Visible Spectrophotometer LUS-A22
Single Beam UV/Visible Spectrophotometer LUS-A22
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 0.5 nm, 1 nm, 2 nm, 4 nm adjustable
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.1 nm
Photometric Range (-4)A to 4 A
Single Beam UV/Visible Spectrophotometer LUS-A30
Single Beam UV/Visible Spectrophotometer LUS-A30
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 4 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Repeatability ≤ 0.2 nm
Single Beam UV/Visible Spectrophotometer LUS-A40
Single Beam UV/Visible Spectrophotometer LUS-A40
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Photometric Range 0 - 200 % T, (-0.3) to (-3.0)A, 0 - 9999 C