X-Ray Film Processor LXFP-A10

X-Ray Film Processor LXFP-A10 is small footprint and light weight device and the volume of the developer and the fixer is only 5.5 L, which can reduce the chemical renewal period and keep the chemical in a good active condition. It offers replenishment container of 25 L and 90 to 160 s processing time. Designed with microprocessor temperature and speed controller. Lower costs for water and chemicals consumption with high efficiency and maximum energy.

Film format 3 × 6 inches 14 × 17 inches ( Max film Width 356 mm)
Film applicable X-ray, MRI and CT etc.
Process time 90 to 160 s
Time of develop 25 s to 45 s
Capacity (Dev time 25 S) 14 × 17 inches 75 pcs/hour, 10 × 12 : 135 pcs/hour, 4 × 4 inches 970 pcs (in theory)
Adjustable Dev./Fix temperature range 20˚C to 40˚C
Adjustable dryer temperature range 40˚C to 65˚C
Adjustable range of repl. 20 to 200 ml
Chemical replenish mode Automatic/Manual/Continuous replenish during processing Automatic: replenish one time when each X-ray film is processed
Tank volume Develop: 5.5 L and FIX: 5.5L
Replenishment containers 25 L
Anti- crystallization In 4 min intervals
Water consumptions 21/min during processing 0L/min during stand by
Water pipe dimension D= 15 mm
Process producer Develop-Fixer-Washer-Dryer
Ambient temperature -40˚C to 70˚C
Relative humidity 10% to 100%
Ambient air pressure 500 to 1060 hpa
Dimension 865 × 585 × 520 mm
Power consumption 2.64 kW
Current
Power supply 220 V AC to 240 VAC, 50/60Hz
Weight 57 kg
  • Designed with microprocessor temperature and speed controller
  • Automatically controlled alert functions, chemical replenish and low chemical level
  • Designed with keyboard LEDs indicating in all the work conditions
  • Designed with racks, roller, electronic control system, dryer, chemical replenish and circulation system
  • Two output modes can be selected freely before placing order
  • High efficient and quick drying
  • Easy maintenance and service

X-Ray Film Processor is used for automatic film processing, analysis of samples across hospitals, clinics, radiography centers, orthopedic centers, and forensic departments.

Film size 3×6 to 14×17 inch
Maximum film width 14 inch (350 mm)
Tank volume capacity 5.2 L
Processing time 105 s, 135 s, 165 s
Input power Voltage: AC 220 V ± 22 V Frequency: 50/60 Hz ± 1 Hz Power capacity: ≥5 kVA Inner resistance ≤0.5 Ω
Maximum output power P = 110 kV × 36 mA = 4 kW
Nominal power 100 kV,40 mA,0.1s,4k W
Frequency ≥40 kHz
Input power Voltage AC 220 V ± 22 V, frequency 50/60 Hz ±1 Hz; Power capacity: ≥5 kVA Inner resistance ≤0.5 Ω
Maximum output power P = 100 kV × 50 mA= 5 kW
Nominal power 50 kV,100 mA,0.1 s,5 kW
Frequency ≥40 kHz
Film size 3×6 to 14×17 inch
Maximum film width 14 inch (350 mm)
Tank volume capacity 5.2 L
Processing time 105 s, 135 s, 165 s
Film format 3 × 6 inches 14 × 17 inches ( Max film Width 356 mm)
Film applicable X-ray, MRI and CT etc.
Process time 90 to 160 s
Time of develop 25 s to 45 s