Portable X-Ray machine LPXM-A11

Portable X-Ray machine LPXM-A11 is 5 kW portable high frequency X-ray system. It KV adjusting ranges from 40 kV to 110 kV, Continuous adjustment step 1 kV and offers 0.01 s to 4 s exposure time range. Equipped with double digital loops and accuracy control method of simulation. Features with X-ray tube Focus: 0.6/1.8 mm and Anode heating capacity: 40 KJ. The 5 kW digital portable high frequency x ray machine for medical diagnosis, use for human limbs checking, diagnosing, especially used in the wild flow places, battlefield, playground, pet clinic, rescue diagnosis etc.

Input power Voltage AC 220 V ± 22 V, frequency 50/60 Hz ±1 Hz; Power capacity: ≥5 kVA Inner resistance ≤0.5 Ω
Maximum output power P = 100 kV × 50 mA= 5 kW
Nominal power 50 kV,100 mA,0.1 s,5 kW
Frequency ≥40 kHz
KV adjusting range 40 kV to 110 kV, step adjustment is 1 kV
mA adjusting range 20 mA to 100 mA
mAs adjusting range 0.2 mAs to 200 mAs, shifted adjustment
Exposure time range 0.01 s to 4 s
X -ray tube Focus: 0.6/1.8 mm, Anode heating capacity: 40 KJ
Dimension 290 × 260 × 230 mm
Weight 18.8 kg
  • Designed with 6 periods of digital LED display
  • 5 kW portable high frequency X-ray system
  • It choices 48 kinds of presupposed anatomy memory pattern
  • Deft and concise
  • Equipped with double digital loops and accuracy control method of simulation
  • High precision control of tube voltage and tube current
  • Failure self-protection and self-diagnosis

Portable X-Ray machine is used in X-Ray machine for medical diagnosis, use for human limbs checking, diagnosing, especially used in the wild flow places, battlefield, playground, pet clinic, rescue diagnosis etc.

Input power Voltage: AC 220 V ± 22 V Frequency: 50/60 Hz ± 1 Hz Power capacity: ≥5 kVA Inner resistance ≤0.5 Ω
Maximum output power P = 110 kV × 36 mA = 4 kW
Nominal power 100 kV,40 mA,0.1s,4k W
Frequency ≥40 kHz
Input power Voltage: AC 220 V ± 22 V Frequency: 50/60 Hz ± 1 Hz Power capacity: ≥5 kVA Inner resistance ≤0.5 Ω
Maximum output power P = 110 kV × 36 mA = 4 kW
Nominal power 100 kV,40 mA,0.1s,4k W
Frequency ≥40 kHz
Input power Voltage AC 220 V ± 22 V, frequency 50/60 Hz ±1 Hz; Power capacity: ≥5 kVA Inner resistance ≤0.5 Ω
Maximum output power P = 100 kV × 50 mA= 5 kW
Nominal power 50 kV,100 mA,0.1 s,5 kW
Frequency ≥40 kHz
Film format 3 × 6 inches 14 × 17 inches ( Max film Width 356 mm)
Film applicable X-ray, MRI and CT etc.
Process time 90 to 160 s
Time of develop 25 s to 45 s
Film size 3×6 to 14×17 inch
Maximum film width 14 inch (350 mm)
Tank volume capacity 5.2 L
Processing time 105 s, 135 s, 165 s