CO<sub>2</sub> range |
0-20% |
CO<sub>2</sub> recovery time |
(Return to 5% after opening the door for 30 seconds) ≤3 mins |
CO<sub>2</sub> control accuracy |
±0.1% |
CO<sub>2</sub> stability of 5%CO<sub>2</sub> |
±0.1% |
CO<sub>2</sub> uniformity |
±0.1% |
CO<sub>2</sub> sensor |
IR CO<sub>2</sub> sensor |
Shaking frequency |
40-300 rpm |
Shaking Precision |
±1 rpm |
Amplitude |
20 mm |
Drive way |
Three eccentric shaft balance drive type |
Humidity control |
50 to 90% |
37C humidity control accuracy |
The chamber can reach 85%-95% when 37˚ C , and the humidity can be controlled in real time |
Humidity resolution |
0.001 |
Humidity deviation |
±2% |
Related humidity |
Nature vaporate > 95% |
Allowable shaking load |
10 kg |
Temperature control range |
4-65° C |
Temperature control accuracy |
±0.1° C |
Temperature uniformity |
±0.5° C |
Temperature sensor |
PT 100 |
Environment temperature detector |
Independent |
Over temperature protection system |
Independent |
Temperature recover time |
(Return to 37˚ C after opening the door for 30 sec) ≤8 mins |
Heating method |
6 side heating |
Disinfection method |
90˚ C high temp |
Timing range |
0 to 99 hour 59 min |
Platform size (L×B) |
350×350 mm |
Shelf |
1 |
Display |
Digital Color display with touch panel |
Sterilization system |
90 degree high temp. high humidity sterilization system (RHP); UV sterilization (option) |
Controller |
PID |
Interface |
RS485 |
Door Open/close message |
Yes |
Alarm system |
High and low temperature and over temperature; Chamber sensor failure; Independent temperature limiter; Door open; High/low CO2 condensation; Power off alarm; Door temperature sensor failure; Disinfection and sterilization status reminder; Over temp sensor failure and Abnormal function |
Interior dimension (W×D×H) |
505×600×420 mm |
Exterior dimension (W×D×H) |
693×875×753 mm |
Gross Weight |
91 kg |
Power |
1500 W |
Voltage |
220V 50Hz |
Flask Configuration |
50 ml×36, 100 ml×23, 250 ml×13, 500 ml×8, 1 L×5, 2 L×3, 4 L×1, 5 L×1 |
- Touch screen interface with Screen lock while functioning
- Infrared CO2 concentration sensor with PT100 temperature sensor
- Outer door ring with heating function
- Independent environment temperature detector
- UV lamp at the back top of chamber
- 90 degree high temperature and high humidity sterilization system with One touch simple sterilization function
- Short sterilization cycle (18 hours) with 72 hours machine performance
- Heating elements: Located on all 6 sides of the chamber
- Alarm system: High and low temperature and over temperature; Chamber sensor failure; Independent temperature limiter; Door open; High/low CO2 condensation; Power off alarm; Door temperature sensor failure; Disinfection and sterilization status reminder; Over temp sensor failure and Abnormal function
- Data logging capabilities with PID controller
- Designed to minimize contamination
Air Jacketed CO2 Incubator are used for tissue engineering, cell culture, in vitro fertilization, diagnostics, neuroscience, cancer research and for developing biosensors across medical research and the pharmaceutical industry.