Haze meter LHM-A10

Haze meter LHM-A10 is used for haze and transmittance measurement. It has open measurement area with no limit on sample size, can carry out vertical measurements as well. It comes with different light sources such as A, C, D65 etc. for haze, transmittance measurement. Design confirms to ASTM & ISO standards, where transmittance compensation measurement provides high accuracy test result.

Light source CIE-A, CIE-C, CIE-D65
Standards ASTM D1003/D1044 & ISO13468/ISO14782
Parameters HAZE, Transmittance(T)
Spectral response CIE Luminosity function y
Wavelength 400 to 700 nm
Wavelength interval 10 nm
Geometry 0/d
Measurement area/sample port 16.5 mm/ 21 mm
Measurement range 0 to 100 %
Haze resolution 0.01
Haze responsibility ≤ 0.1
Sample size Thickness ≤ 145 mm
Display 5.0 inch TFT touch LCD screen
Memory 20000 value
Interface USB
Power 220 V with power cable
Working temperature 0 to 45 °C, Relative humidity 80% or below (at 35 ° C), no condensation
Storage temperature 0 to 50 °C
Dimension (L × W × H) 598 × 247 × 366 mm
  • 5.0 inch TFT touch screen display interface
  • Different light sources A,C, D65 etc. for haze, transmittance measurement
  • Open measurement area with no limit on sample size
  • Confirms to ASTM & ISO haze measurement standard
  • Equipped with software for haze and transmittance
  • Different parameters can be tested like Haze, Transmittance, and Yellowness & Whiteness Index etc.
  • Large storage capacity 100 test samples , 200 measurement records for each sample

Haze meter has applications in haze and transmittance measurement of anti-glare plastic sheets, films, glass, LCD panel screens used for TV screen, car navigation screen, computer screen, mobile phone cover & other transparent & semi-transparent material color.

Light source CIE-A,CIE-C,CIE-D65 Chromaticity Value:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84
Standards ASTM D1003/D1044,ISO13468/ISO14782 & CIE No.15,ISO 7724/1,ASTM E1164
Parameters HAZE, Transmittance(T),Spectral Transmittance<br/> Whiteness Index (ASTM E313-00,ASTM E313-73,CIE/ISO AATCC,Hunter, Taube Berger Stensby) Yellowness Index (ASTM D1925,ASTM E313-00,ASTM E313-73)<br/> Tint(ASTM E313-00), Metamerism Index, Milm APHA, Pt-Co, Gardner, Color Difference(ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00)
Spectral response CIE Luminosity function y
Wavelength Range 420 to 660 nm
Filter 420 nm , 470 nm ,530 nm ,620 nm , 660 nm
High stability and reproducibility ± 5 nm
Economy Consumes only 1.5ml of reagent
Light source CIE-A, CIE-C, CIE-D65
Standards ASTM D1003/D1044 & ISO13468/ISO14782
Parameters HAZE, Transmittance(T)
Spectral response CIE Luminosity function y
Light source CIE-A,CIE-C,CIE-D65 Chromaticity Value:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84
Standards ASTM D1003/D1044,ISO13468/ISO14782 & CIE No.15,ISO 7724/1,ASTM E1164
Parameters HAZE, Transmittance(T),Spectral Transmittance<br/> Whiteness Index (ASTM E313-00,ASTM E313-73,CIE/ISO AATCC,Hunter, Taube Berger Stensby) Yellowness Index (ASTM D1925,ASTM E313-00,ASTM E313-73)<br/> Tint(ASTM E313-00), Metamerism Index, Milm APHA, Pt-Co, Gardner, Color Difference(ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00)
Spectral response CIE Luminosity function y
Illumination Di / 8 (diffusion illumination, 8° viewing), SCI
Size of integrated sphere 40 mm, avian diffused reflection surface coating
Illumination light source CLED
Sensor Sensor array
Illumination Di / 8 (diffusion illumination, 8° viewing), SCI
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Sensor array
Illumination Di / 8 (diffusion illumination, 8° viewing), SCI
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Sensor array
Color measurement method Color card
Illumination system 8°/d (diffusion illumination), SCI (spectral components included)
Display mode Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values<br/> Color difference values: △(L × a × b),△(L × C × h)<br/> Whiteness values: hunter whiteness, Ganz whiteness<br/> Yellowness value: YI
Display screen 2.4 inch LCD display screen
Characteristic function Camera viewing system for measurement
Illumination system 8°/d (diffusion illumination), SCI (spectral components included)
Display mode Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values<br/> Color difference values: △(L × a × b),△(L × C × h)<br/> Whiteness values: hunter whiteness, Ganz whiteness<br/> Yellowness value: YI
Display screen 2.4 inch LCD display screen
Illumination system 8°/d (diffusion illumination), SCI (spectral components included)
Display mode Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values<br/> Color difference values: △(L × a × b),△(L × C × h)<br/> Whiteness values: hunter whiteness, Ganz whiteness<br/> Yellowness value: YI
Display screen 2.4 inch LCD display screen
Measuring calibration About 8 mm