Laser Particle Size Analyzer LLPA-A13

Laser Particle Size Analyzer LLPA-A13 is an intelligent and fully automatic wet laser particle size analyzer, adopted with MIE scattering principle, high-sensitive ring-shaped multi-element silicon photo-diode detector, and unconstrained free fitting software technology. Designed as per ISO13320-1:1999 standard configurations, offers 0.1 to 1000 μm of measuring range with 87 channels and 350 ml sample pool. Equipped with high-performance semiconductor laser and built-in dispersion unit, features auto optical alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion etc. through one-key operation. Incorporated with intelligent SOP operation, automatic and manual mode, has different analysis mode, statistic methods, and statistic comparisons, offers <2 min test time and supports test report in various format.

Dispersion Type Wet
Measurement Range 0.01 to 2000 µm
Channel number 87
Accuracy Error <1% (National Standard Sample D50)
Repeatability Error <1% (National Standard Sample D50)
Light Source High performance semiconductor laser λ = 632.8 nm,<br/> P > 2 mW,<br/> Service life > 25000 hours
Detector High-sensitive ring-shaped multi-element silicon photo-diode detector
Dispersion Method
  • Ultrasonic Frequency: 40 kHz
  • Ultrasonic Power: 35 W
  • Ultrasonic Time: ≥ 1 s
  • Stir Revolution Speed: 0 to 3000 rpm (adjustable)
  • Circulation: Rated Flow: 8 L/min<br/> Rated Power: 10 W
Sample Pool Capacity 350 ml
Optical Path Alignment Fully automatic
Operation mode Automatic/ Manual (Switchable)
Standard ISO 13320-1:2012
Test Speed <2 min/time
Software Running WIN 7/10/XP, 64 bits
Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method Volume Distribution, Quantity Distribution
Test Report Word, Excel, Photo( Bmp), Text etc.
Intelligent operation Intelligent SOP operation
Dimension (L×W×H) 850×390×450 mm
Net Weight 41 kg
  • An intelligent and fully automatic wet laser particle size analyzers
  • Adopted with MIE scattering principle, highly sensitive detectors and detection system
  • Unconstrained free fitting software technology, facilitate the data processing
  • Designed as per ISO13320-1:1999 standard configurations
  • 0.01 to 2000 µm measuring range with 87 channels and 350 ml sample pool
  • High-performance semiconductor laser and built-in dispersion unit
  • Auto optical alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion etc.
  • Intelligent SOP operation with both automatic and manual operation mode
  • Different analysis mode, statistic methods, and statistic comparisons
  • <2 min test time with test report in various format for easy data analysis
  • High-efficient, stable and reliable unit to precisely determine the particle size distribution
10 ml micro sample pool

Laser particle size analyzer is used to measure the sizes of particles in a material across cosmetics, food, coal, paint, paper, petrochemical, dyes, inks, explosives, , kaolin, medicine, metal powder, mica, milling, minerals, oxides industries etc.

Dispersion Type Wet and Dry
Measurement Range Wet: 0.01 to 2000 µm<br/> Dry: 0.1 to 2000 µm
Photodetectors Silicon photodetectors
Channel number Wet: 127<br/> Dry: 100
Dispersion Type Wet
Measurement Range 0.01 to 2000 µm
Channel number 127
Accuracy Error <1% (National Standard Sample D50)
Dispersion Type Dry
Measurement Range 0.1 to 300 µm
Channel number 40
Accuracy Error <1% (National Standard Sample D50)
Dispersion Type Wet
Measurement Range 0.1 to 1000 µm
Channel number 90
Accuracy Error <1% (National Standard Sample D50)
Dispersion Type Dry
Measurement Range 0.1 to 2000 µm
Channel number 100
Accuracy Error <1% (National Standard Sample D50)
Dispersion Type Wet
Measurement Range 0.1 to 300 µm
Channel number 39
Accuracy Error <1% (National Standard Sample D50)
Measuring range 1 μm - 2000 μm
Principle Fraunhofer light diffraction
Spray area range 1 - 10 m
Structure Split-type
Measuring range 1μm to 6000 μm
Technology Computer image analysis technology
Particle properties measured Morphology & size
Particle shape parameters Aspect ratio, sphericity, surface ratio, specific surface area, circumscribed rectangle parameters etc.
Measuring range 2 μm to 6000 μm
Dispersion Ultrasonic, Stirring, Circulation
CCD High speed and resolution CCD (The shutter speed is 10-6/s)
Maximum resolution 1028 × 1024
Dispersion Type Wet
Measurement Range 0.1 to 300 µm
Channel number 39
Accuracy Error <1% (National Standard Sample D50)
Dispersion Type Wet
Measurement Range 0.1 to 1000 µm
Channel number 90
Accuracy Error <1% (National Standard Sample D50)
Dispersion Type Wet
Measurement Range 0.01 to 2000 µm
Channel number 127
Accuracy Error <1% (National Standard Sample D50)
Measuring range 1 nm-10000 nm
Principle Dynamic light scattering & Brownian motion
Test speed < 5 min
Sample type Suspension, emulsion and powders