Portable Multi Parameter Water Quality Meter

Portable Multi-parameter Water Quality Meter LMPWM-A10
Portable Multi-parameter Water Quality Meter LMPWM-A10
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range 0 to 19999 ppm, mg/L, mol/L
Ion accuracy ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
Ion calibration points 2 - 5 points
Ion calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
TDS measurement
TDS range 0 to 100 ppt. (max. 200 ppt., depending on factor setting)
TDS accuracy ± 1 % F.S.
TDS factor 0.1 - 1.0 (default 0.5)
Portable Multi-parameter Water Quality Meter LMPWM-A11
Portable Multi-parameter Water Quality Meter LMPWM-A11
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range
Ion accuracy
Ion calibration points
Ion calibration solutions
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
TDS measurement
TDS range 0 to 100 ppt. (max. 200 ppt., depending on factor setting)
TDS accuracy ± 1 % F.S.
TDS factor 0.1 - 1.0 (default 0.5)
Portable Multi-parameter Water Quality Meter LMPWM-A20
Portable Multi-parameter Water Quality Meter LMPWM-A20
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
TDS measurement
TDS range 0-100 ppt. (max. 200 ppt., depending on factor setting)
TDS accuracy ± 1 % F.S.
TDS factor 0.1 - 1.0 (default 0.5)
Temperature compensation 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Portable Multi-parameter Water Quality Meter LMPWM-A21
Portable Multi-parameter Water Quality Meter LMPWM-A21
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Dissolved oxygen
DO concentration range 0.00 to 20.00 mg/L
DO accuracy ± 0.2 mg/L
Calibration points 1 - 2 points
Pressure correction 60.0 to 112.5 kPa, 450 - 850 mmHg
Salinity correction 0 to 50 g/L
% Saturation of Oxygen 0.0 to 200.0 %
Accuracy ± 2.0 %
Temperature compensation 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Stability conditions Low or high