Halogen Moisture Analyzer LHMA-A20

Halogen moisture analyzer LHMA-A20 with benchtop design has embellished automatic double door, silent opening for the heating chamber. Incorporated with halogen heating lamp for rapid determination of moisture content and dry weight of test sample. The sample is effectively placed in heating chamber at 35 cm height produces accurate results. The user-friendly LCD touch display shows test curve data and other test parameters.

Range 4 mg to 110 g
Readability 1 mg
Temperature range 40 to 230 °C
Communication mode Cable
Heat source Halogen lamp
Pan size 100 mm diameter
Operating temperature range 5 to 35°C
Temperature sensor PT-100
Temperature step 1°C
Temperature setting 40 to 230°C by 1°C
Time setting 1 to 99 min by 10s
Auto stop
Dry residual range 0 to 100 %
Dry residual readability 0.0001
Moisture range 0 to 100 %
Moisture readability 0.0001
Number of storage data 20
Number of history data 20
Rechargeable battery No
Heater part power 220 V ± 15 % 50 Hz, 110 V ± 15 % 60 Hz, 400 W
Balance part power Input: 220 V 50 Hz/ 110 V 60 Hz, Output: 9 V
Mechanical part machine Input: 220 V 50 Hz/ 110 V 60 Hz, Output: 24 V (dual –drive)
Display 7 inch touch panel
Interface RS232/USB
Machine dimension 215 × 195 × 415 mm
Indicator dimension 200 × 75 × 135 mm
Operation height 275 mm
Chamber height 35 mm
Gross weight 10 kg
  • Halogen lamp heating
  • Ergonomically designed pan handle
  • 7 inch smart touch LCD display
  • Long distance operation
  • Maximum 230°C heating temperature
  • Stainless steel chamber
  • Manual setting for time and temperature
  • Easy cleaning after testing
  • Connection to PC, printer

Used in biology, food, agriculture, pharmacy, textile, dye and research industries for determination of moisture content in the test sample.

Range 2 mg to 110 g
Readability 2 mg
Temperature range 40 to 199°C
Heat source Halogen lamp-1
Range 4 mg to 210 g
Readability 1 mg
Temperature range 40 to 230 °C
Communication mode Wireless
Range 4 mg to 210 g
Readability 1 mg
Temperature range 40 to 230 °C
Communication mode Cable
Range 4 mg to 110 g
Readability 1 mg
Temperature range 40 to 230 °C
Communication mode Wireless
Range 1 mg to 110 g
Readability 1 mg
Temperature range 40 to 199°C
Heat source Halogen lamp-2
Range 5 mg to 110 g
Readability 5 mg
Temperature range 40 to 199°C
Heat source Halogen lamp-1
Range 10 mg to 110 g
Readability 10 mg
Temperature range 40 to 199°C
Heat source Halogen lamp-1
Range 1 mg to 110 g
Readability 1 mg
Temperature range 40 to 199°C
Heat source Halogen lamp-1
Measuring range 0 to 40 %
Resolution 0.001
Accuracy 0 to 10 %: ±0.2 % 10 to 40%: ±0.5 %
Scanning depth 50 mm
Measuring grains 25 types
Measuring range 3 to 80%
Operating temperature 0 to 60°C
Operating humidity 5 to 80%
Measuring Element Grain
Moisture Range 3 % to 35 %
Repeating Error ≤ 0.2 %
Measuring Error ≤ ± 0.5 %
Sample weight 0.001 to 120.000 g
Weighing range 0.001 to 120.000 g
Moisture measurement range 0.00 to 100 %
Dry weight measurement range 100 to 0.00%
Measurement Object Poultry meat (pork, beef, lamb, chicken, etc.)
Moisture Measurement Range 10% to 90%
Sampling Time < 2s
Measurement Error In The Range 70 to 78%  ≤  1.0%
Range 2 mg to 110 g
Readability 2 mg
Temperature range 40 to 199°C
Heat source Halogen lamp-1
Range 5 mg to 110 g
Readability 5 mg
Temperature range 40 to 199°C
Heat source Halogen lamp-1
Range 10 mg to 110 g
Readability 10 mg
Temperature range 40 to 199°C
Heat source Halogen lamp-1
Measuring Range 0 to 99 %
Measurement Resolution 0.0001
Measuring Distance 20 to 40 cm
Light Diameter 10 cm