Ubbelohde Viscometer LUV-A10

Ubbelohde Viscometer LUV-A10 has LCD display screen to show the running status of each measurement unit, precisely 6 units at the same time. It has 2 measuring positions & it can obtain intrinsic viscosity through one point method. There is no need to monitor the process after the start in this viscometer, the auto test runs continuously until the test gets completed. It accurately controls the temperature, time & flow rate of fluid tested. It meets FDA & GLP regulations on experiment data management.

Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 2
Bath volume 25 L
Timing accuracy 0.01 s
Temperature range 5 °C - 95 °C
Temperature fluctuation & uniformity ± 0.01 °C
Temperature accuracy Better than ± 0.01 °C
Water bath Inner dimension 540 × 170 × 320 mm
Water bath Outer dimension 610 × 270 × 500 mm
Heating power 1 kW, 220 V
Material applicable PET, PS, SAN, PBT, PMMA, PCT, PA, PIB, TPU, PAM, PSU, PEN, PC, PLA,CA, PVC, SB, Chitin, PAN, TP etc.
  • Display screen controls 6 units at the same time
  • One point method / single concentration method
  • Composed of Stainless steel material
  • Automatic cleaning instead of manual cleaning
  • No need to disassemble ubbelohde viscometer to avoid manmade damage
  • All viscosity formulas present in the system, testing personnel can use them conveniently
  • Data statistics function
  • Provision of basic data for controlling quality of the products
  • Can obtain intrinsic viscosity through one point method
Viscometer tube washer

Ubbelohde viscometer helps in obtaining kinetic viscosity, Dynamic viscosity, Relative viscosity, Viscosity ratio, DP, intrinsic viscosity & average molecular weight of chemical fluids, polymers and biological fluids.

Measure position 1
Oil bath medium Polydimethylsiloxane
Oil bath temperature range 10 °C to 180 °C
Bath volume 8 L
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 6
Bath volume 41 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 4
Bath volume 33 L
Timing accuracy 0.01 s
Measuring range 0.35 to 5000 mm<sup>2</sup>/s
Measure position 2 (4 units measuring position at option)
Bath volume 12 L
Timing accuracy 0.01 s
Measurement range 100 mPa.s to 2000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range 45 to 200°C
Measurement range 100 mPa.s to 200000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range Room temperature to 200°C
Measurement range 25 mPa.s to 1×10000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range 45 to 200°C
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 4
Bath volume 33 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 6
Bath volume 41 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 2
Bath volume 25 L
Timing accuracy 0.01 s
Accuracy ± 2 % (F.S)
Temperature -1℃ to 150℃ (± 0.1℃)
Spindle Details
Spindle No CAP-01 CAP-04
Shear Rate 13.3 N 3.3 N
Sample Volume 67µL 134µL
LCPV-A10 (400rpm) 47-469 300-3,750
LCPV-A10 (750rpm) 25-250 200-2,000
LCPV-A10 (900rpm) 20-208 170-1,667
Note rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s