Automatic (high temperature) Ubbelohde Viscometer LUV-B20

Automatic (high temperature) Ubbelohde Viscometer LUV-B20 with high temperature has 180°C heated oil design. It comes with oil bath medium, 1 measurement unit for viscosity. It is complied in accordance with ISO, ASTM, DIN standards. The less amount of reagents are consumed while using this viscometer. All the viscosity formulas are in the system, for the convenience of the testing personnel.

Measuring range
Measure position 1
Oil bath medium Polydimethylsiloxane
Oil bath temperature range 10 °C to 180 °C
Bath volume 8 L
Bath power 1.5 kW
Timing accuracy 0.001 s
Temperature accuracy ≤ ± 0.03 °C
Sample tray 50 ml × 6
Temperature range
Heating power 3 kW
Dimension (L × W × H) 660 × 320 × 680 mm
Material available UHMPE, PE, PP, PET, PS, SAN, PBT, PMMA, PCT, PA, PIB, TPU, PAM, PSU, PEN, PC, PLAM CA, PVC, SB, Chitin, PAN, TP etc.
  • 1 Measurement unit
  • High temperature environment
  • Less reagent consumption
  • Automatic cleaning instead of manual cleaning
  • No need to disassemble ubbelohde viscometer to avoid manmade damage
  • All viscosity formulas are in the system, testing personnel can use them conveniently
  • Data statistics function
  • Automatic injection

This ubbelohde viscometer is designed for viscosity testing of high temperature (kinetic viscosity, Dynamic viscosity, Relative viscosity) polymers.

Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 2
Bath volume 25 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 4
Bath volume 33 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 6
Bath volume 41 L
Timing accuracy 0.01 s
Measuring range 0.35 to 5000 mm<sup>2</sup>/s
Measure position 2 (4 units measuring position at option)
Bath volume 12 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 2
Bath volume 25 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 4
Bath volume 33 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 6
Bath volume 41 L
Timing accuracy 0.01 s
Accuracy ± 2 % (F.S)
Temperature -1℃ to 150℃ (± 0.1℃)
Spindle Details
Spindle No CAP-01 CAP-04
Shear Rate 13.3 N 3.3 N
Sample Volume 67µL 134µL
LCPV-A10 (400rpm) 47-469 300-3,750
LCPV-A10 (750rpm) 25-250 200-2,000
LCPV-A10 (900rpm) 20-208 170-1,667
Note rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s
Measurement range 25 mPa.s to 1×10000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range 45 to 200°C
Measurement range 100 mPa.s to 200000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range Room temperature to 200°C
Measurement range 100 mPa.s to 2000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range 45 to 200°C