Viscometer LVM-D12

Viscometer LVM-D12 is adopted with advanced technology using micro-processor based system to control speed, test operations, data collection and interpretation. This highly sensitive Brookfield viscometer comes with 100 mPa.s to 2000000 mPa.s measurement range. Equipped with white backlight LCD display enables user to view viscosity test parameters like no. of samples, rotors specification, speed & other important information.

Measurement range 100 mPa.s to 2000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range 45 to 200°C
Temperature control accuracy ± 0.1°C
Sample cylinder 20 ml
Measurement error ± 1% (F.S)
Measurement mode Manual
Print output Thermal printer
Connection to PC RS232 interface
Power supply AC 220V ± 10%, 50 Hz
Relative humidity ≤ 80%
Ambient temperature 5 to 35°C
Dimension 460 × 410 × 450 mm
Gross weight 14 kg
HS Code 90278099
  • Equivalent to Brookfield Viscometer
  • Different rotors selection as per test requirement
  • 04 grades of rotational speed
  • Measurement range 100 mPa.s to 2000000 mPa.s
  • Equipped with Thermal printer
  • Connection to PC via RS232 interface
  • Easy to operate
Accessories No Name
1 Water Bath
2 Rotor No. 30
3 300°C heating furnace
4 Standard viscosity oil- 200 ml
5 Rotor No. 21, 27, 28, 29
6 Rotor No. 0

Used to determine viscosities of asphalt, paraffin, high polymer, pharmaceutical drugs & other liquids in paint & oil industry, pharmaceuticals, food & beverage industry, high polymer and other industries.

Viscosity Range LV: 1 to 6000000 mPa.s
Rotation speed range 0.1 to 250 rpm
Spindles (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy ± 1.0% (of full range)
Rotational speed range 0.3 to 100 rpm
Standard Rotor Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
Viscosity measurement range Rotor R2 to R7:100 to 4000 M (mPa.s)
Standard Rotor Sample Dosage Rotor R1 to R7: 500 ml
Viscosity Range LV: 1 to 2000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles LV: (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy ± 1.0 % (of full range)
Viscosity Range 3 to 1600000 M (mPa.s)
Rotation speed range 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm
Spindles 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml
Rotor 18#,25#,31#,34# (standard configuration)
Measuring range 1 to 100000 mPa.s
Rotating speed 3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±0.5%
Viscosity Range RV: 100 to 40000000 mPa.s
Rotation speed range 0.1 to 250 rpm
Spindles (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0% (of full range)
Measuring range 0.1 to 100,000 mPa.s
Rotating speed 6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range HB: 800 to 104000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Measuring range 1 to 600000 mPa.s
Rotating speed 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Measuring range 1 to 200000 mPa.s
Rotating speed 0.3/0.6/1.5/3.6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Rotational speed range 0.3 to 100 rpm
Standard Rotor Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
Viscosity measurement range Rotor R2 to R7:200 to 26 M (mPa.s)
Standard Rotor Sample Dosage Rotor R1 to R7: 500 ml
Measuring range 1 to 100000 mPa.s
Rotating speed 3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range 40.2 KU to 141.0 KU<br/> 32 g to 1099 g<br/> 27 to 5250 CP
Rotation speed range 200±0.1 rpm
Accuracy ± 3 %
Repeatability ±1.5 %
Viscosity Range RV: 100 to 13000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Viscosity Range HA: 200 to 26000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Measurement range 25 mPa.s to 1×10000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range 45 to 200°C
Measurement range 100 mPa.s to 200000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range Room temperature to 200°C
Measurement range 100 mPa.s to 2000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range 45 to 200°C
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 6
Bath volume 41 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 2
Bath volume 25 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 4
Bath volume 33 L
Timing accuracy 0.01 s
Accuracy ± 2 % (F.S)
Temperature -1℃ to 150℃ (± 0.1℃)
Spindle Details
Spindle No CAP-01 CAP-04
Shear Rate 13.3 N 3.3 N
Sample Volume 67µL 134µL
LCPV-A10 (400rpm) 47-469 300-3,750
LCPV-A10 (750rpm) 25-250 200-2,000
LCPV-A10 (900rpm) 20-208 170-1,667
Note rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s