Tablet Hardness tester LTHT-A11

Tablet Hardness tester LTHT-A11 is designed to detect breaking strength of tablets. It tests hardness value of tablets with specific tablet diameter and specific hardness range. User can reset, recycle the test parameters as its LED screen automatically locks test data being displayed.

Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Resolution 0.1N, 0.01 kg
Measurement accuracy ± 0.5%
Repeated measurement error ± 1 %
Power 40 W
Overall dimension (L × W × H) 400 × 240 × 140 mm
Gross Weight ≤ 20 kg
  • High quality LCD display
  • Equipped with high accuracy pressure sensor
  • Manual single tablet & /Automatic continuation of tablet loading
  • Automatic tablet compression
  • One key conversion for measurement units
  • Automatic linear correction
  • Automatic reset, cycle test, latching function
  • Auto alarm system to diagnose test errors

Used to detect breaking point of tablets for quality, research purpose across pharma, medicine, health, chemical industry.

Hardness measurement range 2 to 196 N, 0.2 to 20 kg
Tablet diameter 2 to 20 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer Yes
Disc Diameter 100 mm
Funnel Outer Diameter Outer diameter 155 mm
Funnel Inner Diameter 145 mm
Test Sample Surfactant Powder and Particles, non-agglomerated powder
Diameter of counting plate 400 mm
Hole No. of counting slide/range 5 to 100 (optional)
Production efficiency 10 to 20 vials/ min
Rate of Bottles 36 bottles/ minute
Number of basket lifting set 3 sets
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Number of basket lifting set 1 set
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Number of basket lifting set 2 sets
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Work Station 2
Sample Volume ≤ 250 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999 (set 0 to output bulk density)
Work Station 3
Sample Volume ≤ 100 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999 (set 0 to output bulk density)
Work Station 1
Sample Volume ≤ 250 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999 (set 0 to output bulk density)
Material Stainless 316 L Stainless Steel
Automatic Grade Semi-Automatic
Power Source Pneumatic
Filling Head Single Head or Double Head or Customized