Tablet Hardness tester LTHT-A10

Tablet Hardness tester LTHT-A10 is designed to detect breaking strength of tablets. It tests hardness value of tablets with specific tablet diameter and specific hardness range. User can reset, recycle the test parameters as its LED screen automatically locks test data being displayed.

Hardness measurement range 2 to 196 N, 0.2 to 20 kg
Tablet diameter 2 to 20 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Resolution 0.1N, 0.01 kg
Measurement accuracy ± 0.5%
Repeated measurement error ± 1 %
Power 10 W
Overall dimension (L × W × H) 280 × 180 × 110 mm
Gross Weight ≤ 20 kg
  • Continuous display of hardness value of tablets on LCD screen
  • Equipped with high accuracy pressure sensor
  • Manual tablet loading
  • Manual tablet compression
  • Unit conversion function for before and after tests
  • Use of standard weight to correct the measurement accuracy conveniently

Used to detect breaking point of tablets for quality, research purpose across pharma, medicine, health, chemical industry.

Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer Yes
Work Station 1
Sample Volume ≤ 250 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999 (set 0 to output bulk density)
Work Station 3
Sample Volume ≤ 100 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999 (set 0 to output bulk density)
Work Station 2
Sample Volume ≤ 250 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999 (set 0 to output bulk density)
Maximum pressure 15 KN
Maximum diameter Tablet 12 mm
Maximum depth of filling 11 mm
Maximum thickness of tablet 6 mm
Maximum pressure 60 KN
Maximum diameter Tablet 25 mm
Maximum depth of filling 16 mm
Maximum thickness of tablet 10 mm
Maximum pressure 50 KN
Maximum diameter Tablet 20 mm
Maximum depth of filling 12 mm
Maximum thickness of tablet 6 mm
Diameter of counting plate 400 mm
Hole No. of counting slide/range 5 to 100 (optional)
Production efficiency 10 to 20 vials/ min
Rate of Bottles 36 bottles/ minute
No of vessels 3
No of poles 3
Position of vessels and poles Three vessel and three pole arranged on one line
Head part movement Manually turn over
No of vessels 6
No of poles 6
Position of vessels and poles Six vessel and six pole arranged on one line
Head part movement Manually turn over
No of vessels 1
No of poles 1
Position of vessels and poles One vessel and one pole arranged on one line
Head part movement Manually turn over
Number of basket lifting set 3 sets
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Number of basket lifting set 2 sets
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Number of basket lifting set 1 set
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm