Disintegration tester LDIT-A11

Disintegration tester LDIT-A11 is adopted with high-precision digital electronic sensor, ensures quality precision and accuracy of the water bath temperature without need for calibration. Equipped with two to three sets of basket, conducts independent disintegration experiments. The default setting for lifting time of the basket is 15 mins, can manually set the other time value as per the experimental need.

Number of basket lifting set 2 sets
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Mesh size 2 mm (as per standard configuration )
Automatic time range 5 to 120 min
Work noise < 60 dB
Temperature prefabrication range Room Temperature to 50°C, display resolution: 0.1 °C
Temperature control accuracy ± 0.3°C
Time prefabrication range 1 to 900 min
Time control accuracy 0.5 min
Accuracy of temperature control 37 ± 0.5°C
Dimension (L × W × H) 400 × 320 × 440 mm
Power supply 220 V/50 Hz
Total power 600 W
Gross Weight 20 kg
  • 2 sets of basket with 12 tubes (6 in each basket)
  • Independent driving for each station
  • Microprocessor controlled automation system
  • Even °C temperature maintenance in water bath
  • Transparent organic glass for water bath
  • Increase and decrease splash proof buttons
  • Automatic system for controlling temperature, time, frequency
  • Alternative display for the preset and real time data
  • Auto-diagnose, auto-alarm system for over-temperature
Accessories no. Name
1 0.425 mm diameter mesh
2 1 mm diameter mesh
3 Beaker

Used for detection of rate of disintegration of solids such as tablets, capsules, pills in required /set (prescriptive) conditions at pharmaceutical industry.

Number of basket lifting set 1 set
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Number of basket lifting set 3 sets
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Number of cylinder 2
Rotating speed of cylinders 25 rpm
Rotating accuracy ± 1 rpm
Counting mode Adopted with countdown, 100 turns can be set arbitrarily
Number of cylinder 2
Rotating speed of cylinders 20 to 100 rpm can be set arbitrarily
Rotating accuracy ± 1 rpm
Counting mode Adopted with countdown, 5 to 900 turns can be set arbitrarily
Number of cylinder 2
Rotating speed of cylinders 25 rpm can be set arbitrarily
Rotating accuracy ± 1 rpm
Counting mode Adopted with countdown, 5 to 900 turns can be set arbitrarily
No of vessels 3
No of poles 3
Position of vessels and poles Three vessel and three pole arranged on one line
Head part movement Manually turn over
No of vessels 1
No of poles 1
Position of vessels and poles One vessel and one pole arranged on one line
Head part movement Manually turn over
No of vessels 6
No of poles 6
Position of vessels and poles Six vessel and six pole arranged on one line
Head part movement Manually turn over
Material Stainless 316 L Stainless Steel
Automatic Grade Semi-Automatic
Power Source Pneumatic
Filling Head Single Head or Double Head or Customized
Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer Yes
Hardness measurement range 2 to 196 N, 0.2 to 20 kg
Tablet diameter 2 to 20 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Diameter of counting plate 400 mm
Hole No. of counting slide/range 5 to 100 (optional)
Production efficiency 10 to 20 vials/ min
Rate of Bottles 36 bottles/ minute