Tablet Hardness tester LTHT-A12

Tablet Hardness tester LTHT-A12 is designed to detect breaking strength of tablets. It tests hardness value of tablets with specific tablet diameter and specific hardness range. User can reset, recycle the test parameters as its LED screen automatically locks test data being displayed.

Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer Yes
Resolution 0.1N, 0.01 kg
Measurement accuracy ± 0.5%
Repeated measurement error ± 1 %
Power 40 W
Overall dimension (L × W × H) 500 × 400 × 160 mm
Gross Weight ≤ 20 kg
  • High quality LCD display
  • Built in printer to print test report
  • Manual single tablet & /Automatic continuation of tablet loading
  • Automatic tablet compression
  • One key conversion for measurement units
  • Equipped with mini printer
  • Automatically calculates tablet return travel (to reduce test time)
  • Superior data analysis, statistics, processing

Used to detect breaking point of tablets for quality, research purpose across pharma, medicine, health, chemical industry.

Hardness measurement range 2 to 196 N, 0.2 to 20 kg
Tablet diameter 2 to 20 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Disc Diameter 100 mm
Funnel Outer Diameter Outer diameter 155 mm
Funnel Inner Diameter 145 mm
Test Sample Surfactant Powder and Particles, non-agglomerated powder
Work Station 2
Sample Volume ≤ 250 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999 (set 0 to output bulk density)
Work Station 1
Sample Volume ≤ 250 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999 (set 0 to output bulk density)
Work Station 3
Sample Volume ≤ 100 ml
Sample Weight ≤ 500 g
Number of Tapping 0 to 99999 (set 0 to output bulk density)
Number of cylinder 2
Rotating speed of cylinders 25 rpm can be set arbitrarily
Rotating accuracy ± 1 rpm
Counting mode Adopted with countdown, 5 to 900 turns can be set arbitrarily
Number of cylinder 2
Rotating speed of cylinders 20 to 100 rpm can be set arbitrarily
Rotating accuracy ± 1 rpm
Counting mode Adopted with countdown, 5 to 900 turns can be set arbitrarily
Number of cylinder 2
Rotating speed of cylinders 25 rpm
Rotating accuracy ± 1 rpm
Counting mode Adopted with countdown, 100 turns can be set arbitrarily
No of vessels 3
No of poles 3
Position of vessels and poles Three vessel and three pole arranged on one line
Head part movement Manually turn over
No of vessels 6
No of poles 6
Position of vessels and poles Six vessel and six pole arranged on one line
Head part movement Manually turn over
No of vessels 1
No of poles 1
Position of vessels and poles One vessel and one pole arranged on one line
Head part movement Manually turn over
Diameter of counting plate 400 mm
Hole No. of counting slide/range 5 to 100 (optional)
Production efficiency 10 to 20 vials/ min
Rate of Bottles 36 bottles/ minute