Rotational speed range |
0.3 to 100 rpm |
Standard Rotor |
Rotor R2 to R7 (6, Standard), R1 (Apolegamy) |
Viscosity measurement range |
Rotor R2 to R7:100 to 4000 M (mPa.s) |
Standard Rotor Sample Dosage |
Rotor R1 to R7: 500 ml |
Measurement error |
± 1 % |
Repetitive error |
± 0.5 % |
Display |
5 inch color touch screen |
Standard configuration |
Shows shear response, timing function |
Real time display viscosity curve |
Time-viscosity curve (standard),
Temperature-viscosity curve (optional temperature probe) |
Kinematic viscosity |
Density of samples to be entered |
Temperature measurement function |
Standard temperature probe interface |
Automatic scanning function |
Automatically scan and recommend the preferred combination of rotor and rotation speed |
Maximum measurement range |
Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range |
Memory |
Built-in 30 program groups (includes rotor speed, temperature, time, etc.) |
Put a seal on |
Data, curve can be printed (standard print interface, need to buy printer) |
Data output interface |
USB, insertion of U disk, Copying data , RS232, Connection to Computer |
Power Supply |
AC 110V/220V, 50Hz/60Hz |
Dimension |
300 × 300 × 450 mm |
Net Weight |
6 kg |
- Adopted with ARM technology, built-in Linux system
- Rich display, 5 inch color touch screen shows (dynamic and kinetic viscosity) temperature, shear rate, date ,time under current rotor speed combination
- High precision automatic measurement, range calibration by computer
- Build-in temperature probe Interface (standard configuration)
- Stepless debugging (speed regulation), measures high viscosity samples
- Built-in 30 groups of test programs, real time display
- Equipped with timing measurement function
- Two RS232 interfaces with direct connection to micro printer and computer
Optional Rotors |
Enhanced ultra-low viscosity adapter ULR, |
|
Small sample adapters (Rotor 21, 27, 28, 29) |
Optional Rotor Viscosity Measurement Range |
URL: 3.2 to 1 K |
|
Rotor 21: 25 to 500 K |
|
Rotor 27: 125 to 2.5 M |
|
Rotor 28: 250 to 5 M |
|
Rotor 29: 500 to 10 M |
Optional Rotor Sample Dosage |
URL: 21 ml, Rotor 21: 7.8 ml, Rotor 27: 11.3ml, Rotor 28: 12.6 ml, Rotor 29: 11.5 ml |
Viscometer is used in glue, latex, adhesives (solvent base), polymer solutions, oil, painting and coating, solvent, cosmetic, dairy products, semi-solid food samples, medicine, juice etc. across it tests all phase, lotion, emulsion, and general solution (liquid phase).