Viscometer LVM-B11

Viscometer LVM-B11 is used to determine a fluid's internal flow resistance or viscosity. This viscometer has bright, easy to read LCD digital display. The viscometer is useful in any area that requires the study of flow of liquids properties. It is user-friendly, and portable in nature.

Measuring range 0.1 to 2,000,000 mPa.s
Rotating speed 0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Repeatability error (Newtonian liquid)) ±0.5%
Time function
Power 110 V/60 Hz or 220 V/50 Hz
Data output RS232C/USB
Dimension 300 ×300 ×450 mm
Net weight 7.5 kg
Gross weight 8 kg
  • LCD panel displays measurement data without secondary calculations
  • Optional temperature probe for the real time measurement
  • Automatic scanner for selecting the best combination of rotor and rotating speed for the test
  • Optional data processing software with real-time recording of viscosity
Accessories No. Name
1 Constant temperature water bath, 10 to 100°C, only 220 V
2 Thermal Printer (with 1 roller paper)
3 Temperature probe
4 Ultra-low viscosity adapter (0 # rotor)
5 Thermostatic cup
6 PC Software RS232-USB Line
7 Calibrate silicone oil 400ml

Viscometer finds major applications in chemical and material industry, cosmetics, petroleum industry, research institutes, for analysis of fluids.

Measurement range 100 mPa.s to 2000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range 45 to 200°C
Viscosity Range 40.2 KU to 141.0 KU<br/> 32 g to 1099 g<br/> 27 to 5250 CP
Rotation speed range 200±0.1 rpm
Accuracy ± 3 %
Repeatability ±1.5 %
Viscosity Range HA: 200 to 26000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Measuring range 0.1 to 100,000 mPa.s
Rotating speed 6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Measuring range 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cP
Rotating speed 0.1 - 200 rpm
Measuring Error (Newtonian liquid) ± 1.0 % full range
Repeatability error (Newtonian liquid)) ± 0.5 %
Measurement range 100 mPa.s to 200000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range Room temperature to 200°C
Measuring range 1 to 600000 mPa.s
Rotating speed 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range LV: 1 to 2000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles LV: (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy ± 1.0 % (of full range)
Viscosity Range HB: 800 to 104000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Measurement range 25 mPa.s to 1×10000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range 45 to 200°C
Measuring range 1 to 200000 mPa.s
Rotating speed 0.3/0.6/1.5/3.6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range 3 to 1600000 M (mPa.s)
Rotation speed range 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm
Spindles 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml
Rotor 18#,25#,31#,34# (standard configuration)
Measuring range 1 to 100000 mPa.s
Rotating speed 3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range RV: 100 to 40000000 mPa.s
Rotation speed range 0.1 to 250 rpm
Spindles (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0% (of full range)
Viscosity Range RV: 100 to 13000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Accuracy ± 2 % (F.S)
Temperature -1℃ to 150℃ (± 0.1℃)
Spindle Details
Spindle No CAP-01 CAP-04
Shear Rate 13.3 N 3.3 N
Sample Volume 67µL 134µL
LCPV-A10 (400rpm) 47-469 300-3,750
LCPV-A10 (750rpm) 25-250 200-2,000
LCPV-A10 (900rpm) 20-208 170-1,667
Note rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s
Measurement range 100 mPa.s to 200000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range Room temperature to 200°C
Measurement range 25 mPa.s to 1×10000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range 45 to 200°C
Measurement range 100 mPa.s to 2000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range 45 to 200°C
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 4
Bath volume 33 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 6
Bath volume 41 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 2
Bath volume 25 L
Timing accuracy 0.01 s