Viscometer LVM-A42

Viscometer LVM-A42 a floor standing rotational digital viscometer used to measure viscosity of liquid sample, semi-solid sample at specified shear rates. Adapted with new ARM technology, built-in Linus system, offers R2 to R7 Rotors (6 standard rotors), viscosity range 200 to 26 M (mPa.s) and 0.3 to 100 rpm rotation speed range (total of 998 speed options). Features a 5-inch color touch screen with visual display of variety of parameters and working conditions to guide users through test creation and data gathering for fast and easy viscosity measurements. It offers several advantages, like measuring multiple parameters, rich display content, convenient operation, intuitive reading, high measuring precision, stable rotational speed, strong anti-interference performance, showing the curve of shear rate, and viscosity, and so on. Each viscosity measuring range is automatically calibrated by a computer with high precision, and less errors.

Rotational speed range 0.3 to 100 rpm
Standard Rotor Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
Viscosity measurement range Rotor R2 to R7:200 to 26 M (mPa.s)
Standard Rotor Sample Dosage Rotor R1 to R7: 500 ml
Measurement error ± 1 %
Repetitive error ± 0.5 %
Display 5 inch color touch screen
Standard configuration Shows shear response, timing function
Real time display viscosity curve Time-viscosity curve (standard), Temperature-viscosity curve (optional temperature probe)
Kinematic viscosity Density of samples to be entered
Temperature measurement function Standard temperature probe interface
Automatic scanning function Automatically scan and recommend the preferred combination of rotor and rotation speed
Maximum measurement range Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range
Memory Built-in 30 program groups (includes rotor speed, temperature, time, etc.)
Put a seal on Data, curve can be printed (standard print interface, need to buy printer)
Data output interface USB, insertion of U disk, Copying data , RS232, Connection to Computer
Power Supply AC 110V/50 HZ, AC220V/50Hz
Dimension 300 × 300 × 450 mm
Net Weight 6 kg
  • Adapted with new ARM technology, built-in Linus system
  • Stepless debugging (speed regulation), measures high viscosity samples
  • 5-inch touch screen with variety of parameters, working conditions: dynamic and Kinetic viscosity, shear rate, shear stress, temperature measurement, and visual display (graphic of curve, range overflow alarm, automatic scanning, date, time etc.)
  • Buil-in 30 group program measurement, real time display of viscosity curves, with data printing
  • High precision automatic measurement, range calibration by computer
  • Equipped with timing measurement function, convenient adjustment of test paramters
  • Standard USB interace, insertion of U disk to copy data directly
  • Optional Pt100 temeprature probe with wide temperature range from -20 to 300°C
Optional Rotors Details
Optional Rotors Enhanced ultra-low viscosity adapter ULR,
Small sample adapters (Rotor 21, 27, 28, 29)
Optional Rotor Viscosity Measurement Range URL: 12.8 to 1 K
Rotor 21: 100 to 333 K
Rotor 27: 500 to 1.7 K
Rotor 28: 1K to 3.3 M
Rotor 29: 2K to 6.6 M
Optional Rotor Sample Dosage URL: 21 ml, Rotor 21: 7.8 ml, Rotor 27: 11.3ml, Rotor 28: 12.6 ml, Rotor 29: 11.5 ml

Viscometer also known as rheometer is a measuring instrument used to determine a fluid's internal flow resistance or viscosity. It finds application in adhesive, latex, paint, cosmetics, ink, pulp, food, oil, starch, solvent, biochemical products and other industries.

Measuring range 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cP
Rotating speed 0.1 - 200 rpm
Measuring Error (Newtonian liquid) ± 1.0 % full range
Repeatability error (Newtonian liquid)) ± 0.5 %
Viscosity Range LV: 1 to 2000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles LV: (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy ± 1.0 % (of full range)
Viscosity Range 3 to 1600000 M (mPa.s)
Rotation speed range 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm
Spindles 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml
Rotor 18#,25#,31#,34# (standard configuration)
Viscosity Range HA: 200 to 26000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Viscosity Range LV: 1 to 6000000 mPa.s
Rotation speed range 0.1 to 250 rpm
Spindles (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy ± 1.0% (of full range)
Measurement range 100 mPa.s to 2000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range 45 to 200°C
Measuring range 1 to 100000 mPa.s
Rotating speed 3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±0.5%
Measuring range 1 to 100000 mPa.s
Rotating speed 3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Measuring range 1 to 200000 mPa.s
Rotating speed 0.3/0.6/1.5/3.6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range RV: 100 to 40000000 mPa.s
Rotation speed range 0.1 to 250 rpm
Spindles (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0% (of full range)
Viscosity Range RV: 100 to 13000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Viscosity Range HB: 800 to 104000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Measuring range 0.1 to 100,000 mPa.s
Rotating speed 6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Measuring range 0.1 to 2,000,000 mPa.s
Rotating speed 0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range 40.2 KU to 141.0 KU<br/> 32 g to 1099 g<br/> 27 to 5250 CP
Rotation speed range 200±0.1 rpm
Accuracy ± 3 %
Repeatability ±1.5 %
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 4
Bath volume 33 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 6
Bath volume 41 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 2
Bath volume 25 L
Timing accuracy 0.01 s
Accuracy ± 2 % (F.S)
Temperature -1℃ to 150℃ (± 0.1℃)
Spindle Details
Spindle No CAP-01 CAP-04
Shear Rate 13.3 N 3.3 N
Sample Volume 67µL 134µL
LCPV-A10 (400rpm) 47-469 300-3,750
LCPV-A10 (750rpm) 25-250 200-2,000
LCPV-A10 (900rpm) 20-208 170-1,667
Note rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s
Measurement range 100 mPa.s to 200000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range Room temperature to 200°C
Measurement range 25 mPa.s to 1×10000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range 45 to 200°C
Measurement range 100 mPa.s to 2000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range 45 to 200°C