Viscometer LVM-A31

Viscometer LVM-A31 is a floor standing rotational viscometer used to measure viscosity of fluid sample at specified shear rates. Its viscosity ranges from 100 to 40000000 mPa.s and offers 0.1 to 250 rpm rotation speed range. The device is RV (Regular Viscosity) range viscometer which uses six set of spindles with a spindle protector. Easy operations, anti-static shell, metal lifter, RTD temperature probe, durable axle, data transfer port, external storage supports, a lot of rotate speed options, etc. are some of the features which ensures safety of user along with ease of handling. It is used in medical laboratories, paint industry, oil and petroleum industry, etc.

Viscosity Range RV: 100 to 40000000 mPa.s
Rotation speed range 0.1 to 250 rpm
Spindles (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0% (of full range)
Repeatability 0.005
Options in unit mPa.s, Pa.s, dPa.s, cP, P, cPs
Probe RTD temperature probe
Display 7 inch LCD touch screen display
Dimension 410 × 380 × 410 mm
Power Supply 100 V to 240 V
Net weight 10 kg
Gross weight 12 kg
  • Designed with 7 inch LCD touch screen display, rich information and easy to operate
  • Equipped with Shear rate, shear stress displayed, Anti-static shell and metal lifter
  • Offers ARM chip processor higher data processing speed
  • Build-in RTD temperature probe and new designed durable axle
  • Powerful human-computer interactive interface
  • It is protected by password for temperature and correction factor
  • Auto switch between dynamic and kinematic viscosity
  • Rotate speed and variety of speed is easy to choose
  • Designed with sound alarm when beyond measurement range
  • Offers different operation interface style and continuous viscosity testing
Accessories no. Name
1DV Software
2Thermostatic water bath
3Ultra-low viscosity adapter
4Small sample adapter
5Standard oil
6Micro printer
7External circulatory glass beaker

Viscometer is used in glue, latex, adhesives (solvent base), polymer solutions, oil, painting and coating, solvent, cosmetic, dairy products, medicine, juice etc.

Rotational speed range 0.3 to 100 rpm
Standard Rotor Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
Viscosity measurement range Rotor R2 to R7:200 to 26 M (mPa.s)
Standard Rotor Sample Dosage Rotor R1 to R7: 500 ml
Measurement range 100 mPa.s to 200000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range Room temperature to 200°C
Viscosity Range 3 to 1600000 M (mPa.s)
Rotation speed range 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm
Spindles 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml
Rotor 18#,25#,31#,34# (standard configuration)
Measuring range 1 to 100000 mPa.s
Rotating speed 3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range 40.2 KU to 141.0 KU<br/> 32 g to 1099 g<br/> 27 to 5250 CP
Rotation speed range 200±0.1 rpm
Accuracy ± 3 %
Repeatability ±1.5 %
Measuring range 1 to 600000 mPa.s
Rotating speed 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Measuring range 0.1 to 2,000,000 mPa.s
Rotating speed 0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range RV: 100 to 13000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Measuring range 0.1 to 100,000 mPa.s
Rotating speed 6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Measuring range 1 to 200000 mPa.s
Rotating speed 0.3/0.6/1.5/3.6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Viscosity Range LV: 1 to 2000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles LV: (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy ± 1.0 % (of full range)
Measurement range 25 mPa.s to 1×10000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range 45 to 200°C
Viscosity Range HA: 200 to 26000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Viscosity Range HB: 800 to 104000000 mPa.s
Rotation speed range 0.3 to 100 rpm (stepless)
Spindles HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy ± 1.0 % (of full range)
Viscosity Range LV: 1 to 6000000 mPa.s
Rotation speed range 0.1 to 250 rpm
Spindles (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy ± 1.0% (of full range)
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 2
Bath volume 25 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 6
Bath volume 41 L
Timing accuracy 0.01 s
Measuring range 0.3 - 50000 mm<sup>2</sup>/s
Measure position 4
Bath volume 33 L
Timing accuracy 0.01 s
Accuracy ± 2 % (F.S)
Temperature -1℃ to 150℃ (± 0.1℃)
Spindle Details
Spindle No CAP-01 CAP-04
Shear Rate 13.3 N 3.3 N
Sample Volume 67µL 134µL
LCPV-A10 (400rpm) 47-469 300-3,750
LCPV-A10 (750rpm) 25-250 200-2,000
LCPV-A10 (900rpm) 20-208 170-1,667
Note rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s
Measurement range 25 mPa.s to 1×10000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range 45 to 200°C
Measurement range 100 mPa.s to 200000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range Room temperature to 200°C
Measurement range 100 mPa.s to 2000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed 5, 10, 20, 50 r/min
Temperature control range 45 to 200°C