Dissolution tester LDLT-A17

Dissolution Tester LDLT-A17 is adopted with adopted with microprocessor controlled technology, automatically controls the temperature, time and rotation speed of experiment. The vessels and poles are fitted in both backward and front positions. The basket and paddle units of these dissolution tester are made of high quality SUS 316L stainless steel. Equipped with magnetism-pumped circular water current, maintains uniform temperature of the liquid throughout the water bath.

No of vessels 12
No of poles 12
Position of vessels and poles Six vessels and six poles in front and other six poles and vessels at back
Head part movement Electrically (automatic) turn over
Preset time 1 to 999 mins
Preset time (for 9 points)
Dimension (L × W × H) 960 × 540 × 480 mm
Speed range 20 to 200 rpm
Speed accuracy ± 2 rpm
Temperature range Ambient to 45°C
Temperature accuracy ± 0.3°C
Time accuracy ± 0.3 %
Paddle radial run out ± 0.5 mm
Basket radial run out ± 1.0 mm
Power supply 220 V, 50 Hz
Power 1200 W
Gross Weight 130 kg
  • LED display shows preset and real data
  • Automatic beeper sound for test point
  • Microprocessor controlled technology
  • Splash proof alphanumeric keypad
  • Auto test, auto diagnosis, auto alarm functions
  • Six vessels and six poles in front and others at back
  • Automatic up and down movement of head part

Used to detect rate (velocity and extent) dissolution limit of pharmaceutical drugs in the form of tablets, pills, capsules etc. in prescriptive form.

No of vessels 8
No of poles 6
Position of vessels and poles Six vessels and six poles in front and other two vessels at back
Head part movement Manually turn over
No of vessels 3
No of poles 3
Position of vessels and poles Three vessel and three pole arranged on one line
Head part movement Manually turn over
No of vessels 6
No of poles 6
Position of vessels and poles Six vessel and six pole arranged on one line
Head part movement Electrically turn over
No of vessels 8
No of poles 6
Position of vessels and poles Six vessels and six poles in front and other two vessels at back
Head part movement Electrically turn over
No of vessels 6
No of poles 6
Position of vessels and poles Six vessel and six pole arranged on one line
Head part movement Manually turn over
No of vessels 8
No of poles 8
Position of vessels and poles Four vessels and four poles in front and others at back
Head part movement Electrically turn over
No of vessels 1
No of poles 1
Position of vessels and poles One vessel and one pole arranged on one line
Head part movement Manually turn over
Maximum pressure 15 KN
Maximum diameter Tablet 12 mm
Maximum depth of filling 11 mm
Maximum thickness of tablet 6 mm
Maximum pressure 50 KN
Maximum diameter Tablet 20 mm
Maximum depth of filling 12 mm
Maximum thickness of tablet 6 mm
Maximum pressure 60 KN
Maximum diameter Tablet 25 mm
Maximum depth of filling 16 mm
Maximum thickness of tablet 10 mm
Number of basket lifting set 1 set
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Number of basket lifting set 3 sets
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Number of basket lifting set 2 sets
Lifting frequency of the basket 30 to 32/ min
Lifting distance of basket 55 ± 1 mm
Minimum spacing from screen to bottom of beaker 25 ± 2 mm
Hardness measurement range 2 to 196 N, 0.2 to 20 kg
Tablet diameter 2 to 20 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer Yes
Hardness measurement range 2 to 200 N, 0.2 to 20 kg
Tablet diameter 2 to 40 mm
No. of testing tablets in each group ≤ 100 tablets
Built in printer No
Material Stainless 316 L Stainless Steel
Automatic Grade Semi-Automatic
Power Source Pneumatic
Filling Head Single Head or Double Head or Customized
Number of cylinder 2
Rotating speed of cylinders 20 to 100 rpm can be set arbitrarily
Rotating accuracy ± 1 rpm
Counting mode Adopted with countdown, 5 to 900 turns can be set arbitrarily
Number of cylinder 2
Rotating speed of cylinders 25 rpm
Rotating accuracy ± 1 rpm
Counting mode Adopted with countdown, 100 turns can be set arbitrarily
Number of cylinder 2
Rotating speed of cylinders 25 rpm can be set arbitrarily
Rotating accuracy ± 1 rpm
Counting mode Adopted with countdown, 5 to 900 turns can be set arbitrarily