Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10 is manufactured with mig burner and loon. It is designed and made as per the International standard ASTM D189 ‘‘Standard Test Method For Conradson Carbon Residue Of Petroleum Products’’. We meticulously designed it for reliability and accuracy.

Porcelain crucible 30 ml
Inner iron crucible 75 ml
Outer iron crucible 190 ml
Burner Mig Burner
Bath type
Heating type
Temperature controlling range
Temperature controlling accuracy
Relative humidity
Dimensions 400 x 380 x 270 mm
Total power consumption
Ambient temperature
Heating power
Power supply
  • Simple design
  • Accessories complete
  • Loon and mig burner

It is widely used in petroleum, chemical and research industries. Also suitable for determining coke black residue formed after petroleum products is evaporated under heating.

Bath type Four holes with a furnace
Heating type Electric resistance furnace
Temperature controlling range 0 ~ 520 °C
Temperature controlling accuracy ± 5 °C
Coking furnace Metal furnace
Heating mode Electric heating
Test unit 5 units
Temperature range Ambient to 550°C
Evaporation bath type and size Aluminum block bath, φ260 × 130 mm
Holes for testing 3 pieces
Size of holes for testing cylinder φ51 × 70 mm
Flow rate display Flow meter
Evaporation bath type and size Aluminum bath φ260 × 130 mm
Holes for testing 5 pieces
Size of holes for testing cylinder φ51 × 70 mm
Working temperature 160 ℃ ~ 165℃
Bath type Oil bath
Bath capacity 5000 ml ± 50 ml
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Cubage of bath Ф300 × 380 mm
Temperature controlling range 0 °C ~ 100 °C
Temperature controlling accuracy ± 0.2 °C
Temperature sensor Industrial platinum resistance, Pt100
Vessel Volume  4000 ml × 2
Power of Vacuum pump 160 W
Negative power 3.7 kPa(27.75 mmHg)
Power of shaking machine 30 W