| Air flow rate | Not less than 150 L / h |
| Max. Preset time | 99 min 59 s (100 min) |
| Chamber diameter of oven | Φ22 mm |
| Heating power of oven | 1400 W × 2 |
| Sample quantity | 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm) |
| Measurement time | 60, 120, 240, 300, and 600 s at random |
| Measurement range | 7 ppm to 5 % |
| Repeatability | < 0.029 (S + 0.6) |
| Measurement item | motor gasoline and diesel |
| measurement unit of octane is ON | 40 to 120 |
| Permissible error of octane | ± 0.5 max |
| Fluctuate range of octane | ± 0.2 max |
| Measuring Range For Aviation Gasoline | 86.0 to 105.0/MON |
| Measuring Range For Gasoline For Motor Vehicles | National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON |
| Measuring Range For Ethanol | E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON |
| Measuring Range For Automobile Diesel Fuels | Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI |
| Temperature measurement range | 10 ~ 35 ℃ |
| Repeatability error | ≤ 0.2 % (Grade C) |
| Endured pressure in oxygen bomb | 20 MPa |
| Operation environment temperature | 15 ~ 28 ℃ |
| Temperature controlling range | 10 ℃ ~ 35 ℃ |
| Temperature resolution | 0.001 ℃ |
| Mean value of heat capacity | 15 kJ / K |
| Ambient temperature | 20 ℃ ± 5 ℃ |
| Heat capacity | 14000 ~ 15000 J / K |
| Temperature measurement range | 10 ~ 35 ℃ |
| Repeatability error | ≤ 0.2 % (Grade C) |
| Endured pressure in oxygen bomb | 20 MPa |
| Beaker quantity | 600 ml |
| Ambient temperature | (-10) °C ~ 40 °C |
| Relative humidity | ≤ 85 % |
| Thermometer Measurement range | (-5) °C ~ 300 °C |
| Ambient temperature | ≤ 35 ℃ |
| Relative humidity | ≤ 85 % |
| Heating power of electric furnace | 250 W × 2 |
| Total power consumption | ≤ 700 W |
| Evaporation bath type and size | Aluminum bath φ260 × 130 mm |
| Holes for testing | 5 pieces |
| Size of holes for testing cylinder | φ51 × 70 mm |
| Working temperature | 160 ℃ ~ 165℃ |
| Bath type | Oil bath |
| Bath capacity | 5000 ml ± 50 ml |
| Ambient temperature | Room temperature to 35 °C |
| Relative humidity | ≤ 85 % |
| Evaporation bath type and size | Aluminum block bath, φ260 × 130 mm |
| Holes for testing | 3 pieces |
| Size of holes for testing cylinder | φ51 × 70 mm |
| Flow rate display | Flow meter |