Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10 is a desktop model, good pressure and corrosion resistance. This instrument is designed and made as per International Standard of Petrochemical ASTM D130 (Test Methods for Detection of Copper Corrosion from Liquefied Petroleum Gas by the Copper Strip Tarnish Test).

Sample hole 2 pieces
Speed of stirring motor 1400 rpm
Ambient temperature 10 to 35°C
Temperature controlling range Room Temperature to 100°C
Temperature controlling accuracy ± 0.5°C
Temperature controller Pt100
Relative humidity ≤ 85 %
Delay time 0.01 s to 99 hours 99 minutes
Heating power 600 W for temperature controlling; 1000 W for auxiliary heating
Total power consumption ≤ 1700 W
Dimensions 580 × 520 × 810 mm
Power supply AC 220 V ± 10 %, 50 Hz
  • Digital temperature controller
  • Stainless steel material test bombs
  • Uniform temperature of water bath and high precision control
  • Equipped with standard color board and copper strips
  • Easy to operate

It is suitable to determine corrosiveness of liquefied petroleum gas to copper strip.

Sample hole 4 pieces
Sample quantity 4 to 12 pieces
Ambient temperature Room temperature to 35 °C
Temperature controlling range Room temperature to 100°C
Sample hole 4 pieces
Ambient temperature Room temperature to 35°C
Temperature controlling range 0 to 100°C
Temperature controlling accuracy ± 1°C
Sample hole 4 pieces
Speed of stirring motor 1400 rpm
Speed for sample stirring 1000 ± 50 rpm
Ambient temperature Room temperature to 35°C
Temperature measurement range 10 ~ 35 ℃
Repeatability error ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb 20 MPa
Operation environment temperature 15 ~ 28 ℃
Temperature controlling range 10 ℃ ~ 35 ℃
Temperature resolution 0.001 ℃
Mean value of heat capacity 15 kJ / K
Ambient temperature 20 ℃ ± 5 ℃
Heat capacity 14000 ~ 15000 J / K
Temperature measurement range 10 ~ 35 ℃
Repeatability error ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb 20 MPa
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Measurement range 0 to 600 penetration scale
Timing controller 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Penetrometer
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.1 penetration
Penetration accuracy ± 1 penetration
Weight of standard needle 2.5 ± 0.05 g
Dimensions (W × L × H) 700 × 400 × 750 mm
Weight 30 kg
Circulatory Water Bath
Bath volume 3.5 L
Temperature range 5 °C to 60 °C
Temperature accuracy ± 0.1 °C
Circulatory water quantity 3 L/minute
Pump Lift 2 m
Power consumption 1200 W
Power supply AC 220V ± 10 %, 50 Hz
Dimensions (W × L × H) 600 × 400 × 650 mm
Weight 40 kg
Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Interior Dimension 360 × 250 × 545 mm
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Power of motor 2 kW
Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode