Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10 is a desktop model, good pressure and corrosion resistance. This instrument is designed and made as per International Standard of Petrochemical ASTM D130 (Test Methods for Detection of Copper Corrosion from Liquefied Petroleum Gas by the Copper Strip Tarnish Test).

Sample hole 2 pieces
Speed of stirring motor 1400 rpm
Ambient temperature 10 to 35°C
Temperature controlling range Room Temperature to 100°C
Temperature controlling accuracy ± 0.5°C
Temperature controller Pt100
Relative humidity ≤ 85 %
Delay time 0.01 s to 99 hours 99 minutes
Heating power 600 W for temperature controlling; 1000 W for auxiliary heating
Total power consumption ≤ 1700 W
Dimensions 580 × 520 × 810 mm
Power supply AC 220 V ± 10 %, 50 Hz
  • Digital temperature controller
  • Stainless steel material test bombs
  • Uniform temperature of water bath and high precision control
  • Equipped with standard color board and copper strips
  • Easy to operate

It is suitable to determine corrosiveness of liquefied petroleum gas to copper strip.

Sample hole 4 pieces
Speed of stirring motor 1400 rpm
Speed for sample stirring 1000 ± 50 rpm
Ambient temperature Room temperature to 35°C
Sample hole 4 pieces
Sample quantity 4 to 12 pieces
Ambient temperature Room temperature to 35 °C
Temperature controlling range Room temperature to 100°C
Sample hole 4 pieces
Ambient temperature Room temperature to 35°C
Temperature controlling range 0 to 100°C
Temperature controlling accuracy ± 1°C
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Power of motor 2 kW
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Interior Dimension 360 × 250 × 545 mm
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Temperature Range Ambient to 100°C
Temperature Precision ± 0.1°C
Air Flow 94 mL ± 5 mL/min, with flowmeters
Timing Unit 0 to 99 min 59 s, resolution 1 s
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃
Beaker volume 1000 mL