Portable 10 in 1 Multi Gas Detector LMGD-A10

Portable 10 in 1 Multi Gas Detector LMGD-A10 is simultaneous detector of 10 gases namely O2, CH4, CO2, VOC, CO, H2S, SO2, CL2, NO2, NH3. It display multiple display modes selectable, multi-channel data mode, multi-curve mode, multi-channel data + multi- curve mode and single channel + single curve mode. Designed with 3.5-inch high-definition color screen, high resolution, wide viewing angle. The air supply system of up to three pumps can switch the pump arbitrarily, blocking the loss of the cross-gas to the relevant sensor and prolonging the service life of the sensor. It support gas concentration data display, gas concentration real-time curve display mode arbitrary switching.

Gas Detected O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3
Detection principle Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)
Measurement Range O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM
Resolution O2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPM
Concentration unit ppm, mg/m3, %VOL, %LEL, can be switched by one button and the concentration value is automatically converted by the internal system
Precision 2% FS
Response Time ≤ 10S
Repeatability ≤ ± 1%
Zero shift ≤ ± 1% (F.S / Year)
Sampling method Built-in stable flow pump, each flow pump is equipped in each independent module, pump flow is adjustable in ten steps, flow range: 0-800 mL/Min
Modular structure 3 detection modules, each module can be selected to detect up to 6 kinds of gases, and a total of 18 kinds of gases can be selected
Display 3.5 inch colour display, resolution 320×480
Display content Gas formula, concentration data, unit of measure, gas curve trend, battery level, time, temperature, humidity, pressure (optional), pump status, wireless status, printer status, screen capture status
Display mode Multiple display modes selectable, multi-channel data mode, multi-curve mode, multi-channel data + multi-curve mode, single channel + single curve mode
Temperature Humidity display range Temperature: -20°C- 50 °C, resolution: 0.1 °C humidity: 0-99% RH, resolution: 1% RH (optional)
Data storage Standard 8G SD card storage function (more capacity can be customized), storage interval can be set by itself, can achieve local storage, view, delete historical data and alarm records, can be directly connected to the computer through USB, quickly download stored data , TXT document; with PC software to download, store, analyze, print data
Communication Output RS232, RS485 signal; with PC software to download, store, analyze, print data (optional)
Wireless transmission Bluetooth (with printer), ZigBee, built-in DTU wireless module (optional)
Printing Built-in printer or external Bluetooth printer (optional), Print Content: Text, graphics, 1D code, 2D code, curve
Screen capture settings The content displayed by the current host saved in the form of a BMP picture, and then the picture exported to the computer through the USB cable for the user to record and reference
Battery capacity 3.7 VDC, 10000 mA rechargeable polymer battery with overcharge, over discharge, over voltage, short circuit protection
Charging interface Micro-USB charging interface is designed to be charged anytime, anywhere with common data lines and mobile power
Operating temperature -0°C-70°C (optional flue gas sampling probe, up to 1200°C smoke concentration)
Working humidity 0-95% RH (no condensation) (high humidity can be selected with filter drying device)
Explosion-Proof Exic II CT3 Gc
Alarm mode Buzzer, red LED and alarm status prompt on the display, fault alarm, pump abnormal alarm, battery low battery alarm, shutdown alarm, fall alarm (optional)
Dimension 260×230×120 mm
Recovery Time ≤ 10S
Linearity error ≤ ± 1%
Degree of protection IP66
Weight 3700 g
  • It simultaneously detects 10 gases namely O2, CH4, CO2, VOC, CO, H2S, SO2, CL2, NO2, NH3
  • Adopting a modular internal structure and obtaining a structural design patent
  • Designed with 3.5-inch high-definition color screen, high resolution, wide viewing angle
  • It use of imported high-precision sensor
  • Built-in three independent air intake modules, zone detection gas, test results are not affected by gas measure range and type, up to 18 gases can be detected
  • It is divided into 3 detection modules, each of which can detect up to 6 gases
  • Equipped with two grade sound and light alarm, alarm point can be set, with built-in large capacity rechargeable lithium battery, can work long time
  • It can be directly connected to the computer through USB, quickly download stored data, TXT document with PC software to download dates in EXCEL
  • Offers standard with metal detection extension rod, suitable for a variety of detection environments
  • It support gas concentration data display, gas concentration real-time curve display mode arbitrary switching

Portable 10 in 1 Multi Gas Detector is used in pharmaceutical, medical, food, corrosion, Disinfection, chemical fertilizers, resins, adhesives and across pesticides, raw materials, samples, process and breeding plants, waste treatment plants, perm places

Sampling method Diffusion
Measurement principle Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
Detector gas Flammable gases, oxygen gas, toxic and harmful gases
Response time
CO2 < 10 s
O2, flammable gases < 20 s
CO, H2S, SO2, NO, ClO2, NO2, H2 < 30 s
HCN, NH3, PH3 < 100 s
Sampling Method Diffusion
Working conditions
Temperature -20 to 50°C
Pressure 0.9 to 1.1 (standard atmospheric pressure)
Humidity 10 to 95 % RH (no dew condensation)
Explosion proof grade Exia II CT3
Protection grade IP65
Gas detected NO<sub>2</sub>
Detection principle Electrochemistry
Sampling method Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure range 0 to1000 ppm
Sampling method Diffusion
Sensor type CO2: solid electrolyte sensor, O2:electrochemical sensor
Detection range CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Detection accuracy CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)
Gas Detected Nitrogen N2
Detection principle Electrochemical principles
Measurement Range 0 to 100 %.Vol
Resolution 0.01 %VOL
Sampling With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
Gas Ethylene C2H4
Measure Range 0 to 1000 ppm
Resolution 1ppm
Gas detected Sulfur dioxide SO<sub>2</sub>
Detection principle Electrochemistry
Sampling method Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure range 0 to1000 ppm
Measurement principle Non-dispersive infrared  (NDIR)
Gas Detected SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
Detection Uncertainty <1.5 % F.S
Detection Resolution 0.1ppm
Measurement range 0 ppm ∼ 5 ppm
Resolution 0.001 ppm ( 0 ppm ∼ 5 ppm )
Temperature range ˗ 40 °C ∼ 120 °C
Humidity range 0 % ∼ 100 % RH
Temperature Measurement Range -10℃ to 60℃
Temperature Resolution 0.1°C
Temperature Accuracy ± 1.5℃
Relative Humidity Range 20% to 80% RH
Capacity 50 kg
Accuracy 1 g
Speed 1 s
Value stable time 2 s
Ozone measurement range 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
Flow rate 1 L/min
Accuracy 0.01 ppm
Measuring time 10 seconds
Sampling Method Diffusion
Working conditions
Temperature -20 to 50°C
Pressure 0.9 to 1.1 (standard atmospheric pressure)
Humidity 10 to 95 % RH (no dew condensation)
Explosion proof grade Exia II CT3
Protection grade IP65
Sampling method Diffusion
Sensor type CO2: solid electrolyte sensor, O2:electrochemical sensor
Detection range CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Detection accuracy CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)
Sampling With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
Gas Ethylene C2H4
Measure Range 0 to 1000 ppm
Resolution 1ppm
Measuring range ± 500 Pa
Repeatability ± 0.2 % FS
Resolution 0.1 Pa
Sampling rate 0.5 s
Measuring range 0 ∼ 125 Pa
Accuracy 0 ± 0.2 Pa (liner error)<hr> ± 1 %
Operating temperature range 0 °C ∼ 50 °C
Operational humidity ˂ 85 RH